HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In_ Out Acreage
Street:
Village: Floor Plan:Commercial:__ Residential:
----
# Bedrooms:_
Owner: Installer:
Address: Phone:
Phone:
Builder: Engineer:
Address: Phone:
Phone:
1. Re.uired#of copies received N A NO
inimi
2. Date of soils exam and .ercolation test not older than 2 years '
3.4-5 ft of naturall occurring .ervious material, above water table
4. Foundation 2 ftabove hi•h .oint of road I
5. Water line 10 ft from s-.tic com.onents Var.:
H'P' Fnd: Var.:
6. Benchmark indicated and shown-NGVD if near wetlands I
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leachi • minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: -- _
9.Leachin• minimum 100 ft from wetlands Var.:
I
10. Leachinb IIIIIIIIIIIIIIIII
minimum 150 ft from drinking well/25 ft irrigation well Var.:
IIIIIIIIIIIIIIIIIMIIIIIII
1L Tank/leaching minimum 10 ft from .ro.ert line Var.:
L 12. System meets all other setback requirements Var.:1IIIIIIMIIIIIIIMIIIIIIII
3. Uses ad'ustment for maximum hio groundwater Var.:
...11.1111111111111
14. Leaching set 4-5 ft above ad'. water or bottom of test hole Var.:
15. S stem not in to. or subsoil (A,B horizons)or 5' removal _
16. Pro.osed contours are suitable
IIIIIIII
17. System meets slope requirements-min. 1/8", '/ preferred ==
18. S stem meets breakout re.uirements
19. S.ecified tee sizes are .ro.er, as baffle on outlet tee PVC liner: Wall:
20. Sewage is under 10,000 :,.d for .arcel - __
21. No garbage dis.osal _._-
22. System ade uately sized for its intended use _-
23.Minimum 6"stone or coma acted below tank and dbox
24. Manhole covers within 6"of a ade, .um. chamber cover to grade -
25. Inspection part on plastic chambers/leach field1111111111111111
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for-tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
•
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
•
Plan reviewed by: