Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out ._ Acreage Street: Commercial: Residential:________ Village: Floor Plan: Bedrooms:_ Owner: Installer: Address: Phone: Phone: Builder: Engineer: Address: Phone: Phone: 1. Re.uired#of copies received - N/A NO 2. Date of soils exam and .ercolation test not older than 2 years 3. 4-5 ft of naturall occurrinc .envious material,above water table 4. Foundation 2 ft above hi•h point of road 5. Water line 10 ft from s-'tic com.onents H.P.. Fnd: Var.: Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Se.tic tank minimum 10 ft from foundation, deck Var.: _ 8.Leachin: minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: -- 9. Leachin. minimum 100 ft from wetlands I I Var.: 10. Leachin. minimum 150 ft from drinking well/25 ft irrigation well Var.: 11111111111111111111111 anli/leachinQ minimum 10 ft from .ro.ert line Var.: i 12. System meets all other setback requirements Var.: __- 13. Uses ad'ustment for maximum hiah groundwater Var.: 14. Leachina set 4-5 ft above ad.. water or bottom of test hole Var.: 111111111111111111111111 15. S stem not in to. or subsoil (A,B horizons)or 5' removal 16.Pro.osed contours are suitable 17. System meets sloe re.uirements-min. 1/8", ''/"preferred - 18. S stem meets breakout re.uirements MINN 19. S.ecified tee sizes are Droner, gas bafflePVC liner. Wall: e �= on outlet tee 20. Sewage is under 10,000 :.d for .arcel -_ 21. No aarbaae dis.osal _ 22. System ade uately sized for its intended use __ 23.Minimum 6"stone or coma acted below tank and dbox 24. Manhole covers within 6"of a ade, Dump chamber cover to grade __ 25. Ins.ection n ort on .lastic chambers/leach field 26. Electrical .errnit for .ums chamber/Se.arate meter for duplexes -- 27.Puma system-2"line,wee. hole,check valve, tee in dbox, •ump size -- 28. Se.tic tank/sum. chamber to be facto wate 'roofed 29. Vent .rovided if leachin below 3 feet,under driveway/parkin° 30. Buo anc calculations for tan .um. chamber � 31. Engineer to ins.ect and certify soils: wall: co _S k/ 32. En:.neer/Re:istered Sanitaria mmercial: n and Land Surve or stam.s/signature =_ 33.H-20 loading is sub'ect to vehicular traffic, : oundwater MINN 34.Title V A..lication and .ennit fee, installer si• .ature11111111111111111111111 35. Foundation footing min. 2 feet above ad'usted around water for new house __ 36.Deed Restriction re.uired max. _- 37. Check area lots for groundwater/Label 1. ound eater in Assessor's Ma.w; d Plan reN,iewed by: -