HomeMy WebLinkAboutEngineer PlansLEGEND 99 — EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 V-7 TEST HOLE Z—% SLOPE OF GROUND COL) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING DCE #07-315 SYSTEM DESIGN LODGE 2: 22 OVERNIGHT CAMPERS ® 31 GPD = 770—GPD 8 DAY CAMPERS ® 10 GPD = 80 GPD YOTAL = 850 GP / SEPTIC TANK: 850 GPD (2) =-1;700 (-FIRST-COMPARTMENT) 850 GPD (1) = 850 GPD ((SECOND COMPARTMENT)-----—' 1,700 + 850 = 2550 GAL. REQUIRED USE A 3000 GAL. DUAL COMPARTMENT SEPTIC TANK & A 1500 GAL. PUMP CHAMBER LEACHING: SIDES: (171.7) 2 (.74) = 254 GPD BOTTOM 812.4 - (.74) =601 -GPD TOTAL: 1155 S.F) 855 GPD USE (8) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) IN FIELD CONFIGURATION SHOWN (SEE DETAIL) APPROVED DATE BOARD OF HEALTH , MA SYSTEM PROFILE LODGE 2 PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE CONCRETE COVERS TO WITHIN 3" GRADE 2" PEASTONE OR GEOTEXTILE MINIMUM .75' OF COVER OVER PRECAST FILTER FABRIC OVER STONE ( 2'5% SLOPE MIN.) FOUNDATION 21' SEPTIC TANK • .. 6" MIN. SUMP 4"OSCH40 PVC a ; ; 12" MIN. INT. DIM. PIPES LEVEL 1 ST 2' "-`���EN3�S 24" TEE 30.55 Q. Io°°o°°oQo°o°o° WATERTEST D'BOX _ j °�°�'^°�°�` -FOR LEVELNESS ;°0°° 1 ° vly' \Z_AB L FlLTER o 35.85' 35.68') o000001. ®® 850 GAL COMP. MIN. OUTLET TEE „ o °000 W/EXTENSION NQTE: 2!MIN. WALL THICKNESS REQUIRED > o 0 0 0 0 0 0 0 0 o c 3/4"-1-1/2" DOUBLE WASHED STONE 'o°oa°o�'°o°o �'�°o°a�'°o°oo°o°o° MIN. 3' AROUND CHAMBERS � o '�o. o 6" CRUSHED STONE OR MECHANICAL SEE DETAIL FOR OVERALL DIMENSIONS TO COMPACTION. (15.221 [2]) ( 2 % SLOPE) (1 % SLOPE) ALL SYSTEM COMPONENTS SHALL BE C TAPE OR COMPARABLE MEANKED WITH S FOR FUTURE LOCATION. NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 2% SLOPE REQUIRED OVER SYSTEM 37.0'-39.03. MINIMUM PIPE ,PITCH TO BE 1/8" PER FOOT. BLOCKS OR 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS PRECAST RISERS TO BE AAST H-229 H-10 / COMPONE S INVERT IN 35.42' 5. PIPE JOINTS TO `BE MADE WATERTIGHT. (TYP') SIDES 36.25' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH ®® ®® >`0000 310 CMR 15.000 (TITLE 5.) '°°°°°°°° ° ° ° ° ®;ooMog o 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO ®®®®®® ®®®mIJ®®® ®:00000000 BE USED FOR LOT LINE STAKING OR ANY OTHER °0°0°0°0 33.42' PURPOSE. rH-20�500 GAL LEACHING CHAMBERS BY ACME PRECAST OR EQUAL8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. (8) UNITS REQUIRED 7F f1T 1' PUMP CHAMBER — 85' - D' BOX 28' LEACHING FACILITY r ALARM AND CONTROL PANEL ;TO BE INSTALLED INSIDE i BUILDING. ALARM TO BE ON I SEPARATE CIRCUIT FROM PUMP I O INV. IN 30.53' ALARM ON FLOAT SWITCH SETTINGS: PUMP ON 4" WORKING RANGE 1500 GAL H-10 950 GAL.+ RESERVE 6" 5" PUMP OFF ,+' = 12 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) PUMP 0 IOC 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED �,, WITHOUT INSPECTION BY BOARD OF HEALTH AND o PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE 28.4' BOTTOM TH-1 LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES NO GROUNDWATER FOUND PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION, INSTRUCT OWNER ON MAINTENANCE. 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION PRIOR TO ORDERING PUMPS. ELECTRICAL PERMIT REQUIRED. PROP. WATERTIGHT COVER TO GRADE 33.5' QUICK DISCONNECT 2" NO LOW POINTS PRESSURE LINE SLOPE TO TO DRAIN BACK TO PC 0.25" WEEP HOLES CHECK VALVES (2) MYERS SRM 4 DUPLEX SUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) CHAMBER (NOT TO SCALE) WATERPROOF/WATERTIGHT LEACHING DETAIL 1 " = 10' PUMP #1 PUMP #2 WYE PUMPS TOGETHER AFTER CHECK VALVES PIPING DETAIL NOT TO SCALE LOCUS MAP NOT TO SCALE ASSESSORS MAP 115 PCL. 233.1.1 SITE IS WITHIN A ZONE II TEST--HOLE--LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 'IVITNESS: BARRY LEWIS QATE: __ 9/28/2023 P\ERC._.RATf—-<' MIN/INCH CLASS I SOILS ELEV. 1 p" 38.4' A LS 10" 1OYR 3/2 B LS 36„ 1OYR 4/4 35.4' PERC C M/CS f' 2.5Y 7/4 {NO GROUNDWATER ENCOUNTERED S_1TE__PL` AN OF LODGE 2 _ �� WHITE ROCK R HOFMAZNOF4AS h,K DANIEL :v YARMOUT"r-00HT, A ,� DANIELA.A. 0JALA yc ,,. OJALA - CIVIL e�EF -1. No. FOR No. 40980 � � •o No. 46502 /,; 5'O �TEq, GATEKIRKLAND�USV�.CA P !I DATE: NOVEMBER 8, 2023�`"�;, x __ Scale: 1"= 20' r� (P � 0 AS n � OF A4,1 T, o� DANIEL "., z DANIELA. A. OJAL4 OJALA „1 " CIVIL Cn Rout ealth Department No. 40980 ! 1,; N0. 46502 TE cssk 1 N0S; 2%111,. S�ONAL G t! e Tate��°' DATE DANIEL A. OJALA, P.E., P.L.S. 0 10 20 30 40 50 FEET off 508-362-4541 I fox 508-362-9880 downcape.com a®n cape en ill eerii , kC. civil engineers land surveyors 939 Main Street ( Rte 6A) SURVEY: NHO YARMOUTHPORT MA 02675 DRAFTED BY: DEG CHECKED BY: 07-315 RUBENSTEIN_2016.DWG