Loading...
HomeMy WebLinkAboutReview Checklist p1LtS ✓ ` ��� TOWN OF YARMOUTH 01L kC w SEWAGE PLAN REVIEW CHECKLIST 1 Location: A.M. Lot Zone of Contribution: In Out_Acreage Street: 1 " pl 4./,k"5( IA_p� Commercial: Residential: Village: Floor Plan: S #Bedrooms: 3 Owner: Installer: T-.D Address: Phone: Phone: Builder: Engineer: �',�%1 V Address: Phone: Phone: N/A YES / NO 1. Required#of copies received �/ 2. Date of soils exam and percolation test not older than 2 years Eli ,/ 3. 4-5 ft of naturally occurring pervious material, above water table ✓ 4.Foundation 2 ft above high point of road H.P.: /QO. nd:lOZ.1 Var.: ✓ 5. Water line 10 ft from septic components Var.: ✓ 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: / 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓ 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 4 .;.keaching set 4-5 ft above adj. water or bottom of test hole Var.: /6 64 System not in top or subsoil(A,B horizons)or 5' removal - �' - 3pY44 •.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee _ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox / 24. Manhole covers within 6"of grade,pump chamber cover to grade ✓✓ / 25. Inspection port on plastic chambers/leach field t/ 26. Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: ✓- 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature Y-20 loading is subject to vehicular traffic, groundwater itle V Application and permit fee,installer signature 3 .Foundation footing min.2 feet above adjusted ground water for new house 036.Deed Restriction required max. #bedrooms: max. flow: gpd t . 37. Check area lots for groundwater/Lab oundwater in Assessor's Map Plan reviewed by: 6/03/03