HomeMy WebLinkAboutEngineer PlanSYSTEM PROFILE NOTES PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 25.0' MINIMUM .70OF COVER (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE NOTE: 2" MIN. WALL PRECAST H-10 IS RISERS (TYP.) THICKNESS REQUIRED BLOCKS OR 4"OSCH40 PVC MORTAR PRECAST RISERS ALL 6" MIN. S INT. DIM. PIPES LEVEL 1ST 2' 4• H-10 COMPONENTS12* (TYP.) 4 ENDS SIDES 22.03' 1500 GAL H-10 °°°° `Y 21.84 TEE SEPTIC TANK9TEE 159' ° ° ° ° °o°o°o°o° ®®®® ®® ®®OO®®® °°°° ,00000000 Y °°°°O°O°O WATERTEHT D'BOX °O9090.090.0 'O°O°O°O° ®®®®®�®�®®®®®�®®®®®® >o°o°o°o° GAS BAFFLE.'.." 0 0 0 0 0 0 O o 0 0 0_ ° ���_° FOR LEVELNESS >°o°o°g°o ®®®�®0�®®®0 ®®®�®®®®®®® >°oOo°o°o °a°o°g°o • - )DO.ODODO ®®®®®®C7®®®® ®®®�®®®I�®®® �00000ODO 19.20' : 4' LIQ. LEVEL (ACME OR EQUAL) .' 21 .47' 21 .30' >°o°o°o°o ' °o°o°o°0 J°O O O O O O O O •O O. O. O O•O O O O O O O O�-L °,00'c�a°o,°,o.00no°,°o�°o�°oo°oo°oo°oo�o,°o�°o,°°o�°o°,°o°�°oo°oe°o° 3/4"-1-1/2 DOUBLE H-10 500 GAL. WASHED STONE 4' MIN. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. ALL AROUND PRECAST STRUCTURES (2) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL L OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) N ( 2-5 % SLOPE) FOUNDATION 14' — LEGEND- - 99 — EXISTING CONTOUR X 99. 1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2*16 SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS WAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: RON CADILLAC WITNESS: -AMY VON HONE, IRS DATE: 8/23/2011 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0,. 26' 0„ PEF 120" 1 1 16' 1 NO GROUNDWATER ENCOUNTERED LICE #20-301 4 ( 1 % SLOPE) (1 % SLOPE) SEPTIC TANK 12' D' BOX 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ZONING SUMMARY ZONING DISTRICT: R-25 TEST HOLE LOGS ENGINEER: RON CADILLAC WITNESS: -AMY VON HONE, IRS DATE: 8/23/2011 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0,. 26' 0„ PEF 120" 1 1 16' 1 NO GROUNDWATER ENCOUNTERED LICE #20-301 4 ( 1 % SLOPE) (1 % SLOPE) SEPTIC TANK 12' D' BOX 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% MAX. BUILDING HEIGHT 35' ELEV. 25.5' Scale:1 "= 20' 0 10 20 30 40 50 FEET LEACHING FACILITY 14.0' BOTTOM TH-2 NO GROUNDWATER FOUND / v7-W DATE 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H—M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. o ��c O o T � 28 Bo�Q Locus Route � 3 o � /er o d oy 3 m 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALL33) AND VERIFYING NG I'ME FLOCATION OF ALL 2UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000't 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 37 PARCEL 90 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. SITE IS NOT LOCATED WITHIN A ZONE II SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED , MA DATE BOARD OF HEALTH Yarmouth Health Department TEi D j Name D e MAR 2 4 2021 H7.ALTH DEPT. TITLE 5 SITE PLAN ) OF #12 TOWN BROOK ROAD WEST YARMOUTH, MA r^, z oF," `o r N %; r , NI PREPARED FOR Ciiv KEN TOMASIAN No.45 02 /_• INOFF,r� _7n� r J DANIEL A. OJALA, P.E., P.L.S. DATE: NOVEMBER 23, 2020 off 508-362-4541 I fox 508-362-9880 downcape.com d®Wa cape �njinte�ing, i7c. civil engineers land surveyors 939 "cin Street ( R to 6A) YARMOUTHPORT MA 02675 20-301