Loading...
HomeMy WebLinkAbout2023 Dec 15 - - J.M. O'Reilly & Associates, Inc. LETTER OF Engineering& Land Surveying Services 1573 Main Street,2nd Floor,P.O. Box 1773 TRANSMITTAL Brewster, MA 02631 (508) 896-6601 Fax(508) 896-6602 TO: DATE: JOB NUMBER: Town of Yarmouth 12/18/2023 8435W Board of Health 1146 Route 28 South Yarmouth, MA 02664-4492 REGARDING: Locus: 46 Doherty Lane, West Yarmouth Shipping Method: Regular Mail n Federal Express Certified Mail n UPS Priority Mail n Pick Up ❑ Express Mail n Hand Deliver _ COPIES DATE DESCRIPTION 1 12/15/23 Routine Operation and Maintenance Checklist for Perc-Rite Drip Dispersal system Gt✓Z ISGV u DEC 2 6 2023 HEALTH DEPT. For review and comment: For approval: As Requested: For your use: 1 REMARKS: cc: John M. O'Reilly, P.E., P.L.S. Client Oakson, Inc. From: GJB If enclosures are not as noted,kindly notify us at once ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: 46 Doherty Lane, West Yarmouth Date: 12/15/2023 Homeowner: Jason Evans Operator: Greg Brehm 16149 Job #: 8435AW HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: 247,829 Design flow: 440 GPD Date of last visit: 12/08/2022 Current flow meter reading: 262,722 Calculated water usage: 40.03 GPD Start-up dose rate Current dose rate ZONE 1: 2.44 GPM 2.8 GPM ZONE 2: ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NOD Comments: B. Air release valves: erosion YES ❑ NOD leakage/spraying YES❑ NOD Comments: PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YESD NOD Comments: B. Alarm float working YESD NOD Comments: C. Solids or scum present YESD NOD Comments: CONTROL PANEL A. Switches in AUTO position YESD NOD Comments: B. Peak Level light on YES❑ NOD Comments: C. Power and Run lights on (microprocessor) YES❑✓ NO❑ Comments: PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YESD NO❑ Comments: B. Zones 1-4 (one at a time): flow meter running YES❑✓ NO❑ dose rate correct YES ID NO❑ flush rate > dose rate YESD NO❑ Comments: C. Disc filter back flushing: working properly YESD NO❑ Comments: D. Disc filter inspection: excessive residue YESD NO❑ cleaning required YESD NO❑ Comments: disc filters cleaned E. Switches returned to AUTO position YESD NO❑ Comments: F. RESET/CYCLE START: functioning properly YESD NO ❑ Comments: G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NOD Comments: SEPTIC and/or PRE-TREATMENT TANKS *did not inspect,covers not to grade A. Examine and clean effluent filter: excessive residue YES❑ NO❑ Comments: B. Septic tank pumping recommended YES❑ NO ❑ 1. Sludge depth: 2. Scum depth: Comments: C. Service pre-treatment system YES❑ NO❑ Comments: N/A Operator signature License No. 16149 Comments/Observations: System is functioning properly at this time.