Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Rev pv plans Benita Pierce.pdf - BLDX-23-15516 29381
PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--THIS PROJECT COMPLIES WITH THE FOLLOWING:2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 INTERNATIONAL PLUMBING CODE2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODE2015 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2020 NATIONAL ELECTRICAL CODEAS ADOPTED BY TOWN OF YARMOUTH (MA)SITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:ROOF MOUNT PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-1ASITE LOCATION (CD)PV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BROOF AND STRUCTURAL TABLESPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-8MICROINVERTER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATIONGREG ALBRIGHT MSPJBUMACCBDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACSUBDCACDCACDCACPV-1AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--THIS PROJECT COMPLIES WITH THE FOLLOWING:2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 INTERNATIONAL PLUMBING CODE2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODE2015 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2020 NATIONAL ELECTRICAL CODEAS ADOPTED BY TOWN OF YARMOUTH (MA)SITE LOCATIONCODES:VICINITY MAP:AHJ REQUIREMENTS:UNUSED MOUNTING PLANES:CONSTRUCTION DOCUMENTSFIRE SETBACKS REQUIRED PER3' ACCESS PATHWAYS TO START FROM"ALLOWED POI OPTIONS = PV BREAKER,LINE SIDE TAPS,LOAD SIDE TAPS,METERADAPTER"SITE LOCATIONINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USINGCONDUIT MOUNT.LAYOUT NOTES: NO ISSUES -- MATCH LAYOUT AS SHOWN ON PLANS.POI NOTES: POI: LINE SIDE TAP // POST-INV BOS: FUSED AC DISCONNECTBOS NOTES: NO ISSUES -- MATCH LAYOUT AS SHOWN ON PLANS.FIRE SETBACKS REQUIRED PER SUBNOTESUPPLY TAB ALLOWED PER UTILITYAC DISCONNECT REQUIRED PER UTILITYUTILITY REQUIREMENTS:DESIGN NOTES:LEGEND:= APPROVED= DISQUALIFIED= SHADING ISSUESN/AHOA REQUIREMENTS:GREG ALBRIGHT MSPJBUMACCBDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACSUBDCACDCACDCACSITE PLANSCALE: 2/25" = 1'-0"1ROOF LINEPROPERTY LINEDRIVEWAY(E) MAIN SERVICE PANEL(N) 25 FREEDOM FOREVER: FF-MP-BBB-400(N) ENPHASE IQ8PLUS-72-2-US(E) UTILITY METER(N) JUNCTION BOXPV SYSTEM10.000 kW-DC7.250 kW-AC75' TO TRANSFORMER - OVERHEAD FEED(N) UTILITY DISCONNECT EATON DG222URB(OR EQUIVALENT)(E) SUB PANELPV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--ROOF AREA: 1824 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTATTACHMENTSMODULESRAFTERSRAILSETBACKMSP AC ACDISCONNECTMSPJUNCTIONBOXPRODUCTIONMETERDC / ACMICROINVERTER PM JB CBCOMBINERBOXPIERCE STREET "AC DISCONNECT SHALL BE 24/7 ACCESSIBLE, WITHIN 10 FEET OF,WITHIN VISIBLE SIGHT OF, AND ON SAME WALL AS THE UTILITY METER(EXCEPTION FOR PEDESTAL METERS)"GREG ALBRIGHT80'- 4 " 44'-6"102'-4"77'-7"93'-4"18'-0"28'-6"22' - 1 0 "38'-3"XIAOJIAN XIEDigitally signed by XIAOJIAN XIE Date: 2023.12.13 12:36:48 -05'00' MSPJBUMACCBDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACSUBDCACDCACDCACPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--ROOF PLANSCALE: 1/8" = 1'-0"1FIRE ACCESSPATHWAYS(E) MAIN SERVICE PANEL(E) UTILITY METERNOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.(E) SUB PANELROOF AREA: 1824 SQ FTROOF PLAN WITH MODULES LAYOUTLEGEND:CHIMNEYPIPE VENTATTACHMENTSMODULESRAFTERSRAILSETBACKMSP AC ACDISCONNECTMSPJUNCTIONBOXPRODUCTIONMETERDC / ACMICROINVERTER PM JB CBCOMBINERBOX(N) ENPHASE COMBINER BOXTOTAL ROOF AREA: 1824 SQ FTTOTAL ARRAY AREA: 525.48 SQ FTARRAY COVERAGE: 28.81%SYSTEM DISTRIBUTED WEIGHT: 2.32 LBSUNIRAC: FLASHKIT PRO POINT-LOAD: 17.15LBSGREG ALBRIGHT3'-0"3'-0" 3'-0" 3'-0" 3'-0"3'-0"3'-0"3'-0" PV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--ROOF DETAILSROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREAROOF 192828276.43313 SQ FT189.17 SQ FTROOF 252727186.43220 SQ FT105.1 SQ FTROOF 3488186.43177 SQ FT84.08 SQ FTROOF 47282896.43313 SQ FT147.14 SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FTROOF DETAILS:TOTAL ROOF AREA: 1824 SQ FTTOTAL ARRAY AREA: 525.48 SQFTARRAY COVERAGE: 28.81%SYSTEM DISTRIBUTED WEIGHT: 2.32 LBSUNIRAC: FLASHKIT PRO POINT-LOAD: 17.15 LBSGREG ALBRIGHT FREEDOM FOREVER:FF-MP-BBB-400UNIRAC SM LIGHT RAILUNIRAC L-FOOTATTACHMENTSUNIRAC FLASHKIT PROFREEDOM FOREVER:FF-MP-BBB-400UNIRAC SM LIGHT RAILSOLAR MOUNT RACKING SYSTEM(E) SINGLE LAYER OFCOMP SHINGLE(E)2X10 RAFTER @ 16" O.C.5/16"x3.5" SS LAG BOLTWITH MIN 212" THREADEMBEDMENT, SEALEDPENETRATIONUNIRAC CHANNEL NUTGROUNDING END/MIDCLAMPUNIRAC L-FOOTATTACHMENTSUNIRAC FLASHKIT PRO2X10 RAFTER @ 16" O.C.3" MIN.6" MAX.TABLE 1 - ARRAY INSTALLATIONROOFPITCHROOFING TYPEATTACHMENT TYPEFRAMING TYPEMAX UNBRACEDLENGTH(FT.)STRUCTURALANALYSIS RESULTPENETRATIONPATTERNMAXATTACHMENTSPACING (IN.)MAX RAILOVERHANG(IN.)ROOF 128Comp ShingleUnirac Flashkit Pro2x10 @ 16" O.C.12PASS PER IEBCSTAGGERED6421.33333ROOF 227Comp ShingleUnirac Flashkit Pro2x10 @ 16" O.C.12PASS PER IEBCSTAGGERED6421.33333ROOF 38Comp ShingleUnirac Flashkit Pro2x10 @ 16" O.C.8PASS PER IEBCSTAGGERED6421.33333ROOF 428Comp ShingleUnirac Flashkit Pro2x10 @ 16" O.C.12PASS PER IEBCSTAGGERED6421.333331. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY.2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS.3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS.ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--MOUNTING DETAILSSTAGGERED DETAILFor Illustration purposes onlySTACKED DETAILFor Illustration purposes onlyGREG ALBRIGHT 4 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" EMT CONDUITJUNCTIONBOXNEMA 3RINVSTRING-212 FREEDOM FOREVER: FF-MP-BBB-400BRANCH CABLES INTEGRAL TOINVERTERS 1 #6 AWG, BARECOPPER GROUNDENPHASE IQ8PLUS-72-2-USMICROINVERTERSINVSTRING-113 FREEDOM FOREVER: FF-MP-BBB-400ENPHASE IQ8PLUS-72-2-USMICROINVERTERSBRANCH CABLES INTEGRAL TO INVERTERS1 #6 AWG, BARE COPPER GROUNDUM(E) 200A / 2PMAIN BREAKER(E) UTILITYMETER(E) 225A RATEDMAIN LUG SUB PANEL1PH, 120/240V 60HZ(N) 40A / 2PPV BREAKEREXISTING WIRE RUNTHROUGH CONDUIT(E) 200A RATEDMAIN BREAKER ENCLOSURE1PH, 120/240V 60HZTO UTILITYOVERHEADFEED3 - #8 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A RATEDAC DISCONNECTEATON DG222URB (OREQUIVALENT) KNIFEBLADE, LOCKABLE,NEMA 3R, UL LISTED3 - #8 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) ENPHASECOMBINER BOX(N) 20A / 2P(N) 20A / 2P(N) 15A / 2PIQ GATEWAYNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 30.25A @ 240V30.25X1.25=37.81AMPS40A BREAKER - OKSEE 705.12 OF 2020 NEC200X1.20=240240-200=40A ALLOWABLE BACKFEEDPV SYSTEM10.000 kW-DC7.250 kW-ACPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--THREE LINE DIAGRAMGREG ALBRIGHT1 PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOMICROINVERTER2104017.241140.0021.552ACMICROINVERTERTOJUNCTION BOX2104015.731140.0019.663ACJUNCTION BOXTOENPHASE COMBINER BOX4104015.7310.832.0019.664ACENPHASE COMBINER BOXTOAC DISCONNECT385530.251155.0037.815ACAC DISCONNECTTOPOI385530.251155.0037.816ACSUBPANELTOMSP33/0225200.0011225.00200.00----------------------------------------------------------------------------CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--QTY.PARTPART #DESCRIPTION25MODULESPV-110-400FREEDOM FOREVER: FF-MP-BBB-4001JUNCTION BOXRAC-261-527600VDC NEMA 3R UL LISTED JUNCTION BOX1MOUNTING BRACKETRAC-211-201UNIRAC E-BOSS J-BOX MOUNTING BRACKET4ELECTRICAL ACCESSORIESEA-350-326STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)4EQUIPMENT ACCESSORIESEA-350-327STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)25INVERTERSINV-120-015ENPHASE IQ8PLUS-72-2-US1MONITORING EQUIPMENTME-180-100-3C"ENPHASE AC COMBINER W/ ENVOY PCB, 80A"29ELECTRICAL ACCESSORIESEA-160-106"ENPHASE, Q CABLE PORTRAIT FOR 60/72 CELL"29ELECTRICAL ACCESSORIESEA-160-105"ENPHASE, Q CABLE LANDSCAPE 60 CELL"1MONITORING EQUIPMENTME-180-200ENPHASE COMBINER BOX NEMA 3R RATED1WIREWR-310-300"ENPHASE, RAW TRUCK CABLE (300 FT. ROLL)"200ELECTRICAL ACCESSORIESEA-160-110ENPHASE TIE WRAPS / CABLE CLIPS7ELECTRICAL ACCESSORIESEA-160-107ENPHASE SEALING CAPS FOR Q CABLE3ELECTRICAL ACCESSORIESEA-160-109ENPHASE TERMINATOR1DISCONNECTSEE-321-06060A RATED 240VAC NEMA 3R UL LISTED3ELECTRICAL ACCESSORIESEA-350-113IDEAL B-TAP 4/0-10 AWG71FITTINGS/ANCHORSRAC-241-250UNIRAC: FLASHKIT PRO16RAILSRAC-211-100UNIRAC SM LIGHT RAIL 168 INCH (TOTAL 217 FEET NEEDED)71FITTINGS/ANCHORSRAC-261-517BND T-BOLT AND NUT SS27ENDS/MIDSRAC-221-101SM MIDCLAMP PRO DRK27ENDS/MIDSRAC-221-209SM ENDCLAMP PRO W/ END CLAMP9FITTINGS/ANCHORSRAC-261-600BND SPLICE BAR PRO SERIES MILL27FITTINGS/ANCHORSRAC-261-510MICRO MNT BND TBOLT SS7RAILSRAC-211-209-NSE-BOSS CONDUIT MOUNT COMP KIT14RAILSRAC-211-200E-BOSS RAIL TRAY5RAILSRAC-211-206E-BOSS BRIDGE TRAY8RAILSRAC-211-207E-BOSS BRIDGE CLIPSOCPD SIZES:20A BREAKER20A BREAKER40A BREAKERSERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)EVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:16 PIERCE STREET,W YARMOUTH , MA 02673PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:30.25A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16PM NEC 705.12(D) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCENEC 690.31(D)(2)J/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAAN/A6015OPTIONAL SOLAR LOAD CENTERARRAYPV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWN MSPJBUMSUBPV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--ENPHASE MICROINVERTER CHARTMICROINVERTER CHARTGREG ALBRIGHT11-1516-3031-4546-6023456789101112131415 MSPJBUMACCBDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACSUBDCACDCACDCACPIERCE STREET PV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--SAFETY PLANGREG ALBRIGHTSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THEPRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ONTHE JHA SHEETINCIDENT REPORTING:INJURIES - CALL INJURY HOTLINE(855) 400-7233*If injury is life threatening, call 911 first THEN the Injury HotlineNON-INJURIES - USE MOBILE INCIDENT REPORTING(Auto, Property Damage, Near Miss)NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC:NAME: _______________________________________________ADDRESS: ___________________________________________NEAREST HOSPITAL:NAME:_______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATION:NAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN ANDSIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THEPLAN FOR WORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OBREAK AND WATER LOGTHIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS ISCOMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREESNAME0800HRS0900HRS1000HRS1100HRS1200HRS1300HRS1400HRS1500HRS1600HRS JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:383798DESIGNED BY:N.W.CLIENT:BENITA PIERCE16 PIERCE STREET, W YARMOUTH, MA02673AHJ: TOWN OF YARMOUTH (MA)UTILITY: EVERSOURCE ENERGY (EASTERNMA)METER: 40112761APN: YARM-000031-000039PHONE: (508) 292-5548EMAIL: BENITAPIERCE@COMCAST.NETSYSTEM:SYSTEM SIZE (DC): 25 X 400 = 10.000 kWSYSTEM SIZE (AC): 7.250 kW @ 240VMODULES: 25 X FREEDOM FOREVER:FF-MP-BBB-400MICROINVERTERS: 25 X ENPHASEIQ8PLUS-72-2-USDATE:12/12/2023N.W.12/12/2023----1--SAFETY PLANGREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINKPV INSTALLATION REFERENCESFREEDOM REFERENCESBATTERY INSTALLATION REFERENCESENPHASESOLAREDGE TESLAINSTALL HOTLINETESLA Storage SystemsNON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage SystemsMisc. Quick GuideFOR INSTALLATION REFERENCE ONLYV1.4 Performance Figures in %MECHANICAL LOADINGMODULE SPECIFICATIONS1722±21722.0 MM1316.0 MM227.2 MMTEMPERATURE RATINGSPACKAGING INFORMATIONMECHANICAL CHARACTERISTICSOPERATIONS CHARACTERISTICS35[1.38]UL 61730 | UL 61215 | ISO 9001 | ISO 14001ELECTRICAL CHARACTERISTICS forL. Matthew Snyder, Certification Manager DATA SHEETIQ8 and IQ8+ MicroinvertersOur newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down*• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesMicrogrid-forming• Complies with the latest advanced grid support**• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) Note:IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system.© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change.*Only when installed with IQ System Controller 2, meets UL 1741. **IQ8 and IQ8Plus support split-phase, 240V installations only.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions.IQ8SP-12A-DS-0067-03-EN-US-2022-12-27(1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8 and IQ8+ MicroinvertersINPUT DATA (DC) IQ8-60-2-USIQ8PLUS-72-2-USCommonly used module pairings1W235 – 350 235 – 440Module compatibility 60-cell / 120 half-cell54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half-cell and 72-cell / 144 half-cellMPPT voltage rangeV27 – 37 27 – 45Operating rangeV16 – 48 16 – 58Min. / Max. start voltageV22 / 48 22 / 58Max. input DC voltageV50 60Max. continuous input DC currentA10 12Max. input DC short-circuit currentA25Max. module IscA20Overvoltage class DC portIIDC port backfeed currentmA0PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ8-60-2-USIQ8PLUS-72-2-USPeak output powerVA245 300Max. continuous output powerVA240 290Nominal (L-L) voltage / range2V240 / 211 – 264Max. continuous output currentA1.0 1.21Nominal frequencyHz60Extended frequency rangeHz47 – 68AC short circuit fault current over 3 cycles Arms2Max. units per 20 A (L-L) branch circuit316 13Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed currentmA30Power factor setting1.0Grid-tied power factor (adjustable) 0.85 leading – 0.85 laggingPeak efficiency%97.7CEC weighted efficiency%97Night-time power consumptionmW60MECHANICAL DATAAmbient temperature range -40°C to +60°C (-40°F to +140°F)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (H x W x D) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesPollution degreePD3Enclosure Class II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure rating NEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 Product specificationsEaton DG222URBCatalog Number: DG222URBEaton General duty non-fusible safety switch, single-throw, 60 A, NEMA 3R,Rainproof, Painted galvanized steel, Two-pole, Two-wire, 240 VGeneral specificationsEaton general duty non-fusible safetyswitchDG222URB7821131442387.38 in 14.38 in8.69 in 9 lbEaton Selling Policy 25-000, one (1) yearfrom the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.UL ListedWARNING! Switch is not approved forservice entrance unless a neutral kit isinstalled.Product Name Catalog NumberUPCProduct Length/Depth Product HeightProduct Width Product WeightWarranty CertificationsCatalog NotesEaton Corporation plcEaton House30 Pembroke RoadDublin 4, IrelandEaton.com© 2023 Eaton. All RightsReserved.Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners.Eaton.com/socialmediaProduct specificationsGeneral duty safety switchPainted galvanized steelNon-fusible, single-throwNon-fusible2NEMA 3R240V60ATwo-poleResourcesEaton's Volume 2—Commercial DistributionDouble Up on SafetySwitching Devices Flex CenterEaton Specification Sheet - DG222URBSelling Policy 25-000 - Distribution and Control Products and ServicesProduct CategoryEnclosure materialTypeFuse configurationNumber of wiresEnclosureVoltage ratingAmperage RatingNumber Of PolesCatalogsMultimediaSpecifications and datasheetsWarranty guides IDEAL INDUSTRIES, INC. 1375 Park Avenue s 6017.com ALL IDEAL Customers 2/9/23 Subject: The Buchanan B-TAP® splice/tap connectors meet the 2020 NEC article 230.46 requirement for line side applications The Buchanan B-TAP® brand of insulation piercing connectors which correspond to part numbers beginning with BTC meet the requirements of article 230.46 of the 2020 NEC. These products have already been tested to the newer requirements. The installation instructions are in the process of being updated to show the required notation: suitable for use on the line side of the service equipment. This change will take a few weeks to get into our production. In addition, the marking SR will be added to the product. That addition is in process and will take a few months to complete. This notice will provide confirmation to the inspectors that B-TAP® products meet the requirements of the 2020 and 2023 NEC article 230.46 Spliced and Tapped Conductors. Sushil Keswani Director of Engineering IDEAL Industries, Inc., THE COMPLETE ROOF ATTACHMENT SOLUTIONFEATURING TECHNOLOGYFLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac’s patented SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks. .LWWHGLQSDFNVIRUPD[LPXPFRQYHQLHQFHƜDVKLQJVDQGKDUGZDUHDUHDYDLODEOHLQ0LOORU'DUNƛQLVKHV With FLASHKIT pro, you have everything you need for a quick, professional installation.YOUR COMPLETE SOLUTIONFlashings, lags, continuous slot L-Feet and hardwareCONVENIENT 10 PACKS Packaged for speed and ease of handlingFLASHKIT PRO25 YEAR FULL-SYSTEM WARRANTYTRUSTED WATER SEAL FLASHINGS)25 48(67,216 25 &86720(5 6(59,&( 9,6,7 81,5$&&20 25 &$// FASTER INSTALLATION. 25-YEAR WARRANTY.FLASH.,7352,67+(&203/(7()/$6+,1*$1'$77$&+0(1762/87,21)25&20326,7,21522)6)25 48(67,216 25 &86720(5 6(59,&( 9,6,7 81,5$&&20 25 &$// PRE-INSTALL• Locate roof rafters and snap chalk lines to mark the installation point for each roof attachment.• 'ULOODƌSLORWKROHDWHDFKURRIDWWDFKPHQW)LOOHDFKSLORWKROHwith sealant.STEP 1 ,167$// FLASH.,7352)/$6+,1*• $GGD8VKDSHGEHDGRIURRIVHDODQWWRWKHXQGHUVLGHRIWKHƜDVKLQJwith the open side of the U pointing down the roof slope. Slide WKHDOXPLQXPƜDVKLQJXQGHUQHDWKWKHURZRIVKLQJOHVGLUHFWO\XSVORSHIURPWKHSLORWKROHDVVKRZQ$OLJQWKHLQGLFDWRUPDUNVRQWKHORZHUHQGRIWKHƜDVKLQJZLWKWKHFKDONOLQHVRQWKHURRIWRFHQWHUWKHUDLVHGKROHLQWKHƜDVKLQJRYHUWKHSLORWKROHLQWKHURRI:KHQLQVWDOOHGFRUUHFWO\WKHƜDVKLQJZLOOH[WHQGXQGHUWKHWZRFRXUVHVRIVKLQJOHVDERYHWKHSLORWKROHSTEP 2 ,167$///)227• )DVWHQ/IRRWDQG)ODVKLQJLQWRSODFHE\SDVVLQJWKHLQFOXGHGODJEROWDQGSUHLQVWDOOHGVWDLQOHVVVWHHOEDFNHG(3'0ZDVKHUWKURXJKWKH/IRRW(3'0JURPPHWDQGWKHUDLVHGKROHLQWKHƜDVKLQJLQWRthe pilot hole in the roof rafter.• 'ULYHWKHODJEROWGRZQXQWLOWKH/IRRWLVKHOGƛUPO\LQSODFH,WLVQRUPDOIRUWKH(3'0RQWKHXQGHUVLGHRIWKHVWDLQOHVVVWHHOEDFNHG(3'0ZDVKHUWRFRPSUHVVDQGH[SDQGEH\RQGWKHRXWVLGHHGJHRIthe steel washer when the proper torque is applied.TIP: • 8VHFDXWLRQWRDYRLGRYHUWRUTXHLQJWKHODJEROWLIXVLQJDQLPSDFWGULYHU• 5HSHDW6WHSVDQGDWHDFKURRIDWWDFKPHQWSRLQWSTEP 3 $77$&+/)227725$,/• ,QVHUWWKHLQFOXGHG7EROWVLQWRWKHORZHUVORWRQWKH5DLOVROGVHSDUDWHO\VSDFLQJWKHEROWVWRPDWFKWKHVSDFLQJEHWZHHQthe roof attachments.• Position the Rail against the L-Foot and insert the threaded end of WKH7%ROWWKURXJKWKHFRQWLQXRXVVORWLQWKH/)RRW$SSO\DQWLVHL]HWREROWWKUHDGVWRSUHYHQWJDOOLQJRIWKH7EROWDQGLQFOXGHGƌVHUUDWHGƜDQJHQXW3ODFHWKHƌƜDQJHQXWRQWKH7EROWDQGƛQJHUWLJKWHQ5HSHDW67(3XQWLODOO/)HHWDUHVHFXUHGWRWKH5DLOZLWKD7EROW$GMXVWWKHOHYHODQGKHLJKWRIWKH5DLODQGWRUTXHHDFKEROWWRIWOEV,167$//FLASH.,7352)/$6+,1*STEP 1 STEP 2 STEP 3 ,167$///)227 $77$&+/)227725$,/FLASHKIT PRO INSTALLATION GUIDE SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block!NOW FEATURING FLASHKIT PROThe Complete Roof Attachment SolutionNOW WITH UNIVERSAL MIDCLAMPSAccommodates 30mm-51mm module frames One tool, one-person installs are here!REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End CapsTHE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNTOPTIONAL FRONT TRIMNew & Improved: THE PROFESSIONALS’ CHOICEWith Superior AestheticsCONCEALED UNIVERSAL CLAMPSW WITH UNIVERSAL MIDCLAMPIWITHTHUUNINEVESRSRSALALALMMIDICLCLAMP25 YEAR FULL-SYSTEM WARRANTYFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORTENGINEERINGEXCELLENCEUNMATCHEDEXPERIENCEPERMITDOCUMENTATIONDESIGNTOOLSCERTIFIEDQUALITYBANKABLEWARRANTYBETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOLStart the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money.BETTER SYSTEMSONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics.BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOBTrust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAMProfessional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information.UNIVERSAL SELF STANDING MIDCLAMPSU-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEYVisit design.unirac.comBANKABLE WARRANTYDon’t leave your project to chance, Unirac has the ƛQDQFLDOVWUHQJWKWREDFNRXUSURGXFWVDQGUHGXFH\RXUULVNHave peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year OLPLWHGSURGXFWZDUUDQW\DQGD\HDUOLPLWHGƛQLVKZDUUDQW\TECHNICAL SUPPORTUnirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly VLPSOLƛHV\RXUSHUPLWWLQJDQGSURMHFWSODQQLQJSURFHVVCERTIFIED QUALITY PROVIDERUnirac is the only PV mounting vendor with ISO FHUWLƛFDWLRQVIRUDQG2+6$618001:2007, which means we deliver the highest standards IRUƛWIRUPDQGIXQFWLRQ7KHVHFHUWLƛFDWLRQVGHPRQVWUDWHRXUH[FHOOHQFHDQGFRPPLWPHQWWRƛUVWFODVVEXVLQHVVSUDFWLFHVUL2703BONDING & GROUNDINGMECHANICAL LOADINGSYSTEM FIRE CLASSIFICATIONLISTEDSOLARMOUNTCONCEALED UNIVERSAL ENDCLAMPSEND CAPS INCLUDED WITH EVERY ENDCLAMPENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAINFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 Project: 80082031 Date Issued: 2021-06-02 Issued To: Unirac 1411 Broadway NE Albuquerque, New Mexico, 87102 United States Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems -Certified to US Standards Models: SM - SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA - Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. Solarmount Certificate: 70131735 Project: 80082031 Master Contract: 266909 Date Issued: 2021-06-02 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, 10, 19, 22 or 25 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. UL 2703 Mechanical Load ratings: Downward Design Load (lb/ft²) 113.5 Upward Design Load (lb/ft²) 50.7 Down-Slope Load (lb/ft²) 16.13 Test Loads: Downward Load (lb/ft²) 170.20 Upward Load (lb/ft²) 76.07 Down-Slope Load (lb/ft²) 24.2 Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPENDIX HTechnicalData SheetsUnitsinplfin²SECTION MODULUS (X-AXIS)in³SECTION MODULUS (Y-AXIS)in³MOMENT OF INERTIA (X-AXIS) in4MOMENT OF INERTIA (Y-AXIS)in4RADIUS OF GYRATION (X-AXIS)inRADIUS OF GYRATION (Y-AXIS)in0.564 0.865 1.170.15 0.363 0.8980.067 0.113 0.2211.271CROSS SECTION AREA0.409 0.625 1.059BEAM HEIGHT1.70 2.57 3.00APPROX WEIGHT0.491 0.7280.254 0.269 0.5020.13 0.467 1.450.026 0.045 0.267PropertiesSOLARMOUNT LightSOLARMOUNT Rail Profile 2SOLARMOUNT HDPAGE H3TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458