Loading...
HomeMy WebLinkAboutEngineer PlanI SURVEY WITH EXISTING TOPOGRAPHY, UTILITIES AND PROPERTY BOUNDARIES PROVIDED BY DEMAREST LAND SURVEYING, PLS DATED 5 DECEMBER 2023. MAP 114 PCL. 62 APPROXIMATE LOCATION OF EXISTING LEACHING CHAMBERS. TO BE COMPLETELY REMOVED. SEE NOTES MAP 114 PCL. 63 EXISTING 1,500 GAL. SEPTIC TAN REMAIN. ZABEL FILTER TO BE AE OR REPLACED, IF NECESS LEGEND SOIL TEST PIT EXISTING CONTOUR �p PROPOSED CONTOUR OVERHEAD ELECTRICAL BURIED ELECTRICAL G MUNICIPAL WATER NATURAL GAS LINE 51 GORDON LANE ASSESSORS MAP 114 PARCEL 80 SITE PLAN SCALE: 1" =10' CD 0 10 20 VARIANCES / SITE NOTES: MAP 114 1 PROPERTY IS NOT LOCATED WITHIN A FLOOD ZONE PCL. 81 2. THE PROPERTY IS LOCATED WITHIN A ZONE 11 INTERIM WELLHEAD PROTECTION AREA. 3. THE PROPERTY IS NOT PROXIMATE TO A TITLE 5 BUFFER 4. NO DRINKING WATER WELLS WITHIN 100 FEET OF PROPOSED SYSTEM. MAP 114 PCL. 79 d 5 INFILTRATOR 3050 CHAMBERS TONE ON SIDES, VON ENDS Wx37.58'Lx2.5'H C INSPECTION PORT r D Z M 9 n 7 5 FIRST FLOOR PLAN (NOT TO SCALE) (UNFINISHED BASEMENT) SECOND FLOOR PLAN (NOT TO SCALE) Schedule of Invert Elevations Location Design As -built 4" @ sewer invert @ foundation 45.80 4" @ septic tank IN 45.40 3" @ septic tank OUT 45.15 4" @ D-box IN 44.40 3" @ D-box OUT 44.23 Chambers INLET 44.18 Top of Units (TOS) 44.85 Bottom of System (BOS) - - 42.35 Finished Grade oversystem (FG) 47.00 NEW ZABEL FILTER ADDED TO EXISTING T A = 48.0 SEPTIC TANK 105 ± " MIN. ay 3" MIN. .4. "MITa ZABLE FILTER 12" MAX. EXISTING 1,500 GALLON SEPTIC TANK (TO SYSTEM PROFILE REMAIN) NOT TO SCALE Design Tie -out Table (in feet) LOCATION X Y A (SAS corner) 40.3 27.3 B (SAS corner) 33.7 16.7 C (SAS corner) 69.1 47.3 D (SAS corner) 1 72.5 52.0 47 ± j DISTRIBUTION BOX (H-20) LOCUS 51 Gordon Ln VICINITY MAP NOT TO SCALE GENERALNOTES 1. THIS PLAN IS INTENDED FOR THE DESIGN OF THE SEWAGE DISPOSAL SYSTEM ONLY AND IS NOT TO BE USED TO ESTABLISH NEW OR EXISTING PROPERTY LINES OR DWELLINGS. 2. LOCATION OF WATER, GAS AND ELECTRIC UTILITY LINES IS APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING DIGSAFE AT 1-888-344-7233 AND THE YARMOUTH WATER DEPARTMENT PRIOR TO CONSTRUCTION. 3. INSTALLATION SHALL BE IN ACCORDANCE WITH THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.000), THE LOCAL BOARD OF HEALTH REGULATIONS, AND THE CULTEC SEPTIC MA DESIGN AND INSTALLATION MANUAL. 4. THE CONTRACTOR MUST HOLD A VALID INSTALLER LICENSE IN THE TOWN OF YARMOUTH. 5. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE LOCAL BOARD OF HEALTH OF ANY CHANGES TO THESE PLANS. 6. CONTRACTOR SHALL CALL FOR INSPECTIONS AND APPROVALS FROM THE BOARD OF HEALTH AND THE ENGINEER AFTER: 6.1. EXCAVATION OF SAS AREA EXPOSING THE BOTTOM OF SYSTEM. 6.2. INSTALLATION OF SYSTEM COMPONENTS PRIOR TO BACKFILL. 7. ALL PIPING AND FITTINGS SHALL BE SCHEDULE SDR 35 PVC UNLESS OTHERWISE SPECIFIED. 8. FINISHED GRADE OVER THE SAS SHALL HAVE A MINIMUM 2% SLOPE. 9. EXISTING 1,500 GALLON SEPTIC TANK SHALL BE USED AS SECOND SEPTIC TANK IN SERIES. A ZABEL FILTER SHALL BE PLACED ON THE OUTLET FROM THE SECOND TANK. 10. EXISTING SYSTEM COMPONENTS SHALL BE CRUSHED, REMOVED AND REPLACED WITH TITLE 5 FILL. 11. NO GARBAGE GRINDER SHALL BE INSTALLED AT THE EXISTING DWELLING. H2O RISER AND COVER TO WITHIN 6" OF FINISHED GRADE FILTER FABRIC PLACED ON TOP AND 47-46.5± SIDES OF SAS 9" MIN. TO 36" MAX. COVER SOIL EVALUATION TEST PIT LOGS Address: 51 Gordon Ln, Yarmouth, MA Test Date: 10/12/2023 Soil Evaulator: Dave Mason SE#1501 Test Hole 1: Elev. = 47.0 DEPTH (inches) HORIZON / LAYER TEXTURE (USDA) COLOR (Munsell) 0-8 A Loamy Sand 10YR3/1 8-30 B Loamy Sand 10Y6/1 30-158 C Medium Sand 10YR7/4 Notes: No groundwater observed. SHGW estimated at bottom of pit. (EL = 33.83) Percolation Test Location: Depth Results Rate TP1 42" could not saturate <2 mpi DESIGN CALCULATIONS 4 Bedrooms x 110 GPD/Bedroom 440 GPD SEPTIC TANK (Per31OCMR15.233) First Compartment: Minimum 48 Hours Flow 880 gallons Second Compartment: Minimum 24 Hours Flow 440 gallons Minumum Total Volume: 1320 gallons SOILABSORPTION SYSTEM: Loading Rate (310CMR.15): 0.74 GPD/sq ft Area = 440 GPD / 0.74GPD/sq ft 594.6 sq ft Select 5 Infiltrator 3050 Chambers: 3.5 ft of stone on sides, 1 ft of stone on ends Bottom Area =11.25 ft x 37.58 ft 422.8 sq ft Side Wall Area = 2 x (11.25 ft + 37.58 ft) x 1.83 ft 178.7 sqft Total Leaching Area = Bottom + Side Wall Area 601.5 sq ft Area x 0.74 GPD/sq ft 44S.1 GPD /� PERFORATED 1 SAS PIPING 41NCH INSPECTION PORT TO GRADE. ----- ----- J, - - - - - ----- 5 INFILTRATOR 3050 UNITS -----' << I - 37.58' SOIL ABSORPTION SYSTEM (SAS): BOTTOM ON LEVEL, STABLE BASE 5 INFILTRATOR 3050 CHAMBERS MECHANICALLY COMPACTED WITH 6" 3.5' STONE ON SIDES,1 FT ON ENDS CRUSHED STONE 11.25' W x 37.58' L x 1.83' H TOS BOS R b '_: - � -W L Robial Water LTD 85 Courtland Street Providence, RI 02909 P: +1(508) 954 0677 E:jay@robialwater.com CONSULTANTS: � � o SPEAKMAN EXCAVATING LLC 235 Great Western Rd Dennis, MA 02660 P: +1(508) 432 5565 E: info@speakmanexcavating.com Yarmouth Health Department ARJAIOVED Name Date nECEIVED QFC 1 1 2023 HEALTH DEPT. ---------------1 I AAA44 N OF Mgss9cti - So JAY M. GN g` THRASHER �} oC-3 CIVIL on No.54434 f # 0 ° LE' ` I I I I I I I I I L-------------J No. REVISION/SUBMISSION DATE COPYRIGHT 2023 - Robial Water Ltd. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of Robial Water Ltd. PROJECT No. T52023.036 SHEET TITLE: SITE LAYOUT & SYSTEM DESIGN SHEET SIZE: 24 IN. X 36 IN. (ARCH D) DATE: 7 December 2023 SHEET NUMBER: SHEET 1 Of 1 PROJECT: RESIDENTIAL ONSITE WASTEWATER TREATMENT SYSTEM REMEDIAL CONSTRUCTION 51 Gordon Lane Yarmouth Port, MA 02675