HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In
Out Acreage
Street: Commercial:__ Residential:
Village: ___-_--
Floor Plan: #Bedrooms:
Owner: -` ---
Address: Installer:
Phone: Phone:
Builder:
Address: Engineer:
Phone: =I
Phone:
1. Re.uired#of copies received N/ANO
2. Date of soils exam and .ercolation test not older than 2 years '
nane
3. 4-5 ft of natural! occurring .envious material, above water table
4. Foundation 2 ft above hi•h soint of road
5. Water line 10 ft from s-.tic components Var. Fnd: Var.:
6. Benchmark indicated and shown-NGVD if near wetlands I -
7. Se•tic tank minimum 10 ft from foundation, deck _-
Van.:
8.Leachi ! minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leachin• I -- _
minimum 100 ft from wetlands
Var.:
10. Leaclun• minimum 150 ft from drinking well/25 ft irrigation well Var.:
IIIIIIIIIIIIIIIIIIIIII
•rig minimum 10 ft from •ro•ert line Var.:
12. System meets all other setback requirements __-
13. Uses ad.ustment for maximum hiahVar: 111111111111111.111111111
groundwater Var.:
14. Leaching set 4-5 ft above ad.. water or bottom of test hole Var.:
15. System not in to. or subsoil (A,B horizons)or 5' removal 11111111111111111
16. Pro•osed contours are suitable
17. System meets slope requirements-min. 1/8", '''A"preferred • -
18. S stem meets breakout re.uirements --
19. S.ecified tee sizes are .ro.er, gas baffle on outlet tee PVC liner: Wall: _�20. Sewaae is under 10,000 ;.d for .arcel -_
21. No garbage disiosal 111111 ,__
22. System ade uately sized for its intended use --
23.Minimum 6"stone or corn.acted below tank and dbox _
24. Manhole covers within 6"of g ade, sump chamber cover to grade -
25. Ins.ection sort on .lastic chambers/leach field =�_
26. Electrical .ermit for sum. chamber/Se.arate meter for du.lexes
27. ?urn. system-2"line,wee. hole,check valve, tee in dbox, •ump size _
28. Se.tic tank/sum• chamber to be facto wate 'roofedIIIIIIMIIIIIIII
29. Vent •rovided if leachin below 3 feet,under driveway/.arkina
30.Buo anc calculations for-tank/sum. chamber --
31. En_'neer to ins.ect and certi __
32. En_'neer/Re_istered Sanitarian and Land Survesor stam.s/siwgnature ll: commercial: �
33.H-20 loadina is sub.ect to vehicular traffic, : oundwaterIIIIIIIIIIIIIIIIIIIIIII
34.Title V A..lication and •ermit fee, installer si• 'attire
35. Foundation footing min. 2 feet above ad'usted?round water for new house --
36. Deed Restriction re•uired max. #bedrooms: max. flow: ..d -
37. Check area lots for groundwater/Label • oundwater in Assessor's Ma.
Plan reviewed by: