HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out
Acreage
Street: Commercial:___ Residential:
Village: _ __--
Floor Plan: #Bedrooms:
Owner:
Address: Installer:
Phone: Phone:
Builder:
Address: Engineer:
Phone: Phone:
1. Re.uired#of copies received NO
2. Date of soils exam and .ercolation test not older than 2 years ' -
3. 4-5 ft of naturall occurrin• .ervious material,above water table
4, oundation 2 ft above hi•h .oint of road
Fnd: Var.:
5. Water line 10 ft from s-.tic com.onents Var.:
1 NMI
6. Benchmark indicated and shown-NGVD if near wetlands
7. Settle tank minimum 10 ft from foundation, deck Var.: _
8.Leachi _minimum 20 ft full, 15 ft crawl, 10 ft slab Var,: - _
9. Leachin• minimum 100 ft from wetlands _
Var.: I
10 Leachin• minimum 150 ft from drinking well/25 ft irrigation well Var.:
" " ne mintmum 10 ft from .ro.ert line Var.: IIIIIIMIIIIIIIIIIIIIII
12 System meets all other setback requirements -_
13. Uses ad ustment for maximum high groundwater Var.:
14. Leachina set 4-5 ft above ad.. water or bottom of test hole Var.`
15. System not in to. or subsoil (A,B horizons)or 5' removal _
16. Pro.osed contours are suitable
17. System meets slo.e requirements-min. 1/8", 'A"preferred -
18. S stem meets breakout requirements --
19. S.ecified tee sizes are .ro.er, aas baffle on outlet tee PVC liner: Wall: ( _�20. Sewaae is under 10,000 Aid for .arcel - __
21. No oarbaoe dis.osal _
22. S stem ade uately sized for its intended use -_
23.Minimum 6"stone or come acted below tank and dboxMN
24. Manhole covers within 6"of grade, .ump chamber cover to grade -_
25. Ins.ection .ort on elastic chambers/leach field __�_
26. Electrical .ermit for .um. chamber/Se.arate meter for du.lexes --
IIIIIIII
27. Pura. system-2"line,wee. hole,check valve, tee in dbox, .ump size _Pura.28. Se.tic tank/gum. chamber to be facto wate .roofed
29. Vent .rovided if leachin below 3 feet,under driveway/parkin__ IMMEMINIMMINII
30. Buo anc calculations for tank/.um. chamber -
31. En_'neer to insect and certify soils: wall: co _�32. En_ neer/Re;istered Sanitarian and Land Surve or stam.s/si nature mmercial: __
33.H-20 loading is subiect to vehicular traffic, : oundwater -_
34.Title V A..ligation and 'emit fee, installer si• 'attire1110111111111111111.111
35. Foundation footing min. 2 feet above ad'usted Around water for new house __36.Deed Restriction re•uired max. __
37. Check area lots for groundwater/Label • oundwater Assessor's Ma. dMIN
Plan reviewed by: