HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In
Out Acreage
Street l� I{C'r,, '� n Commercial:__ Residential:
Village. /
Floor Plan: • a Bedrooms:_
Owner:
%� r Installer:
Address.
Phone: Phone:
Builder:
Address: Engineer:
Phone: Phone:
1. Re.uired#of co.ies received inEMMI NO
2. Date of soils exam and .ercolation test not older than 2 years
3. 4-5 ft of naturally occurrin• pervious material, above water table
4. Foundation 2 ft above hi•h •oint of road
Fnd: Var.:
5. Water line 10 ft from s-.tic com.onents Var. ME6. Benchmark indicated and shown-NGVD if near wetlands I MN
7. Septic tank minimum 10 ft from foundation, deck MIME
8. Leachin• minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I - _
9 Leachm minimum 100 ft from wetlands ar.:
I _
10. Leachin• minimum 150 ft from dnnkinc well/25 ft irrigation well Var.: I
IIIIIMIIIIIIIIIIIIIII
12 System meets all other setback requirements �� Var.:
1111111.1111111111
13 Uses ad.ustment for maximum high groundwater Var.: \
14. Leaching set 4-5 ft above ad.. water or bottom of test hole Var.:
15. System not in to. or subsoil (A,B horizons)or 5' removal E=.m.mmnm--------IIIIIIIMIIIIIIMIIIIIII
16. Proposed contours are suitable
17. System meets sloe re.uirements- min. 1/8", V."preferred ■ -
18. S stem meets breakout re•uirements --
19. Specified tee sizes are .roper, gas baffle on outlet tee PVC liner: Wall: I -_20. Sewage is under 10,000 Aid for parcel - __
21. No oarbaoe disposal _
22. System ade uately sized for its intended use __
23.Minimum 6"stone or com.acted below tank and dbox Mil
24. Manhole covers within 6"of grade, .ump chamber cover to grade S-
25. Inspection port on .lastic chambers/leach field111111111111111111
26. Electrical permit for 'urn. chamber/Separate meter for duplexes _--
27. Pum. system-2"line,wee. hole,check valve, tee in dbox, sump size _-_
28. Se.tic tank/.um. chamber to be facto wate 'roofed
29. Vent .rovided if leachin below 3 feet,under driveway/parkin° _611111.1111.1111.1
30. Buo anc calculations for tank/sums chamber -_
31. Enineer to inspect and certify soils: wall: commercial: _�32. En: neer/Re:istered Sanitarian and Land Surve or stamps/signature
MEN
33.H-20 loading is sub-ect to vehicular traffic, : oundwater __-
34.Title V A..lication and permit fee, installer signature
35. Foundation footing min. 2 feet above ad'usted Around water for new house _-_36.Deed Restriction re•uired max. --
37. Check area lots for groundwater/Label ound bedrooms:
er Asses ora's Ma. d
MIN•
Plan reviewed by: