HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In
Out Acreage
Street: Commercial:
Residential:
Village: --_-
Floor Plan: # Bedrooms:
Owner: ---
Address: Installer:
Phone: Phone:
Builder:
Address: Engineer:
Phone: Phone:
1. Re.uired#of copies received N/A � NO
2. Date of soils exam and .ercolation test not older than 2 years
1111111111
3. 4-5 ft of naturall occurrin• •ervious material,above water table
4. oiindation 2 ft above hi•h •oint of road
5. Water line 10 ft from s-.tic components Var. Fnd: Var.:
6. Benchmark indicated and shown-NGVD if near wetlands I
7. Septic tank minimum 10 ft from foundation, deck Var.: MINI
8.Leachin_ minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: - _
9. Leachin• minimum 100 ft from wetlands _
Var.:
10. Leachin• minimum 150 ft from drinking well/25 ft irrigation well Var.: •
IIIIIMIIIIIIIIIIIIIII
_ nQ minimum 10 ft from .ro.ert line Var.:
1 12. System meets all other setback requirements Var __
13. Uses ad ustment for maximum high groundwater Var.: \ 111111111.1111111111111111
14. Leaching set 4-5 ft above ad-. water or bottom of test hole Var.:
15. System not in toe or subsoil (A,B horizons)or 5' removal 111111111111111111111
16. Proposed contours are suitable
17. System meets slope re.uirements-min. 1/8", '''A"preferred 11111111.111
-
1 S. S stem meets breakout re.uirements --
-_19. Specified tee sizes are .roper, aas baffle on outlet tee PVC liner: Wall:
20. Sewage is under 10,000 Aid for parcel - __
21. No aarbaoe dis.osal IIIIIIINMIIIIIIIIIIII
22. S stem ade uately sized for its intended use __
23.Minimum 6"stone or comp acted below tank and dbox _
24. Manhole covers within 6"of grade, pump chamber cover to grade S-
25. Inspection port on elastic chambers/leach field
26. Electrical permit for •u . chamber/Separate meter for duplexes _--
m
27.Pump system-2"line,wee. hole,check valve, tee in dbox, pump size _-
28. Septic tank/sum. chamber to be facto wate 'roofed
_
29. Vent .rovided if leachin below 3 feet,under driveway/parkins
30. Buo anc calculations for-tank/sum. chamber -IIII.
31. Engineer to inspect and certify soils: wall: co _�
32. En: neer/Re:istered Sanitarian and Land Surve or stamps/si:nature mrnercial: _�
33.H-20 loading is sub'ect to vehicular traffic, : oundwater _�_
34.Title V Ap.lication and *emit fee, installer si• 'attireimisimini
35. Foundation footing min. 2 feet above ad'usted ground water for new house ___
36.Deed Restriction resuired max. __
IIIIIIIIIIIIIIIII
37. Check area lots for oundwater/LabelTM bedrooms. max. flow: _ d
groundwater in Assessor's Ma. 11111111
Plan reviewed by: -
-. co,0.