Loading...
HomeMy WebLinkAboutBLDE-23-005221 . Commonwealth of Official Use Only P . Massachusetts Permit No. BLDE-23-005221 , BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] . APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/22/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 464 HIGGINS CROWELL RD Owner or Tenant WAHAB EMAD ABDEL Telephone No. Owner's Address C/O EMAD ZAHRAN,464 HIGGINS CROWELL RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) . Purpose of Building Utility Authorization No. t Ci r 6)1 I oli_, Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity % Location and Nature of Proposed Electrical Work: Installation of solar PV system(36 Panels 14.04 KW DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons _ KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal Connection 0 Other: No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 (-2-3 Please email permit to eastmapermits@sunrun.com Z. E C E ' Commonwealth o//rladdachudettd Official Use(Only I g cc�� c�77 Permit No. l l 2p e artm.ent o/.}ire�erviced I MAR 2 2 F'_T e Occupancy and Fee Checked IL r, BOARD OF FIRE PREVENTION REGULATIONS ow, r [Rev. 1/07] (leave blank) BUILDING DEPARTMENT By: IN F LICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 03/20/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)464 Higgins Crowell Rd Owner or Tenant Emad Abdel Wahab Telephone No. (508) 523-4388 Owner's Address 464 Higgins Crowell Rd Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes V No (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 200 Amps / Volts Overhead 1 Undgrd❑ No.of Meters New Service Amps / Volts Overhead Undgrd I I No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a rooftop mounted photovoltaic solar energy system consisting of 36 solar panels producing 14.04 KW DC with No ESS Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tons No.of Alerting Devices Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of WHeaters KW ater No.of No.of Data Wiring: Signs Ballasts No.of Devices or Equivalent No. Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: 18477 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:SUnrun Installation Services Inc. / LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature 1414 LIC.NO.:21136 A (If applicable, enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978 793-7881 *Per M.G.L.c. 147, s. 57-61,security work requires Department of Public Safety"S" License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION FASI •SYSTEM SIZE:14040W DC,9800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(36)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET J •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN,(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL SE6000H-USSN PV-3.0 LAYOUT •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL C. SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 0 AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). ABBREVIATIONS r—1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ARC FAULT CIRCUITINTG S u n r u n AFC ARC FAULT CIRCUITINTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (El EXISTING FLUSH ATTIC VENT VICINITY MAP 606 MYLES STANDISH BLVD TAUNTON.MA OEM-, ESS ENERGY STORAGE SYSTEM PVC PIPE VENT N6ehM6' FAX 0 EXT EXTERIOR - -- i -✓ METAL PIPE VENT Lowell CUSTOMER RESIDENCE: INT INTERIOR - EMAD ABDEL WAHAB MSP MAIN SERVICE PANEL T-VENT 464 HIGGINS CROWELL RD, Lynn YARMOUTH,MA,02673 NI 1 NEW SATELLITE DISH NTS •NOT TO SCALE ' cnmMR1ge Boston TEL.(617)697-2910 OC ON CENTER . FIRE SETBACKS .W5Te6Her Uumry APN:YARM-000074-000067 PRE-FAB PRE-FASRICATED _ PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT HARDSCAPE FEorkton 223R464WAHA PV PHOTOVOLTAIC 0.i..x,•r�.,wn -- DESIGNER: (415)580-6920 ex3 RSD RAPID SHUTDOMNOEVICE —PL— PROPERTY LINE -SOLAR MODULES © la,,,n.., ERI DANIEL-KALIO IL TRANSFORMERLESS 464 Higgins Crowell Rd 7 SCALE:NTS H,rrw�dw,rP SHEET TYP •TYPICAL Yarmouth MA USA 02673 REV NAME DATE COMMENTS COVER SHEET ✓ VOLTS W.N.H. I W WATTS NIHy.Bedford A.CIe.XHiny Service REV:Al 3/17/2023 LAN LANDSCAPE -_TOPSPEED PAGE MOUNT C► PV-1.0 POR PORTRAIT TerVafe Ve n_4087 • SITE PLAN-SCALE=1/16"=1'-0" 1,J t1 ‘'ik..\_,v 3 1 1 ---(N)ARRAY AR-02 (N)ARRAY AR-01 — 'I ° 4,- -. 1 0 ro CM SITE PLAN DETAIL-SCALE=3/128"=1'0" PL ?� PL — � sunrun PL -- \----- , IT, 4' #180120 � - (E)RESIDENCE - ES STANDISH..reurtON.IAA 027e0-7331 CUSTOMER RESIDENCE: EMAD ABDEL WAHAB d" 464 HIGGINS CROWELL RD, 5 c YARMOUTH,MA,02673 c ARRAY TRUE PV AREA ZN / PITCH AZIM (SQFT) TEL.(617)697-2910 C� \ . APN:YARM-000074-000067 �p AR-01 30° 258° 496.7 m Q' AR-02 30' 76° 248.3 PROJECT HAER: ''' . , __________.__y/ 'Pp DESIGNER: (415)580-6920 ex3 ERI DANIEL-KALIO SHEET SITE PLAN PL REV:Al 3/17/2023 PAGE PV-2.O Template ve on_L 0 07 • ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait SNOW LOAD:30 PSF Span Spacing Edge Overhang Overhang WIND SPEED: COMP SHINGLE- 140 MPH 3-SEC GUST. AR-01 TOPSPEED 1-Story 2X6 PRE-FABRICATED TRUSSES 8'-5" 24" TOPSPEED,SEE DETAIL SNR-DC-30004 3 1'-5" 0'-10" S.S.LAG SCREW COMP SHINGLE- (4)#14 X 2.25"SS SEALING AR-02 TOPSPEED 1-Story 2X6 PRE-FABRICATED TRUSSES 8'-5" 24" TOPSPEED,SEE DETAIL SNR-DC-30004 3 1'-5" 0'-10" WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD 01-AR-01-SCALE:1/8"=I-0' DECK AZIM:258° PITCH:30° 1,-3„ 46,-4,, 5-2"--- II IINSTALLERS SHALL NOTIFY ENGINEER OF ANY —�. POTENTIAL STRUCTURAL ISSUES OBSERVED I PRIOR TO PROCEEDING W/INSTALLATION. 4-1 -MOUNT NUMBER FOR LEADING DOWNSLOPE 0 0 0 0 0-0 0-0 e --0 0 0- 000 0 0 0 000 000 ---- EDGE SHALL MATCH REQUIREMENTS LISTED ABOVE INSTALL PER TOPSPEEDTM INSTALLATION MANUAL. --0-e o 0 0- -0 o r-o---0-e- --e-a-' -CONTRACTOR MAY SUBSTITUTE SNAPNRACK 10'-10" DECKTRACK MOUNTS(SNR DETAIL SNR-DC-00453)WITH A MAX OVERHANG OF 6" 10-o a o-o o -o e o- 0 0 o I o o-e -o 0 0 o 0 0 0 0-0 ' 000 000 0 0 0 - 000 000 000 000 000 I �,�„ D2- -SCALE:1/8"=1'-0" AZIM::78 78° sunrun PITCH:30° _.f 3,-11„ 46.-4,,.......__.....__.._.._....__......_.._.__.__._._.._—...........__._._.. __,2.-6"F- I ONISTR Signed: #180120 ONL �, 03/17/2023 3'-10" oa�'�1`1H OF ��'yG PHONE o ees uvLEs srnuoIsH e�w,rAururorv.MA,0ve0-ra3+ 0 0 o o o e -0 0 0 � 0 0 -I 0 ao- 0 0-0 0 0 o e 0 0 -- ��' VINCENT x, .0 L 3'-7" $ MWUMVANEZAILm CUSTOMER RESIDENCE: . �. EMAD ABDEL WAHAB 0 0 0 -0 0 0 - 0 0 0 <r 0 0--—0 0-0 0 0-0 0 0-0 0-© 0 ---+ 9�!// Eo �e 464 HIGGINS CROWELL RD, 1' Ea C ) O 11 •.'/'oraniEHo�� YARMOUTH,MA,02673 - 0 0 0 0 0-0 0 0-0. -00-0--1 8'6„ TEL.(617)697-2910 APN:YARM-000074-000067 ' 0 0 0 -- 0 0 0 -0 0-0- —0-9--0-1 PROJECT NUMBER: 223R-464WAHA +--- 15'-0" — i--- - 23'-2" -14'-1"- { < DESIGNER: (415)5806920 ex3 ERI DANIEL-KALIO SHEET LAYOUT REV:Al 3/17/2023 PAGE PV-3.0 SEE SITE PLAN FOR NORTH ARROW Templa(e_ve n_d.0.87 120/240 VAC SINGLE PHASE SERVICE SOLAREDGE TECHNOLOGIES: SE3800H-USMN METER#: 3800 WATT INVERTER JUNCTION BOX PV MODULES ‹— O EVERSOURCE 2283469 OR EQUIVALENT UTILITY _ li) �— C) (14)AM SOLAR:TSM-390DE09C.07 GRID�— _ ✓� —/- JJ +. ES // OPTIMIZERS WIRED IN: /�-SUPPLY SIDE TAP I I (1)SERIES OF(14)OPTIMIZERS (N)100A PV LOAD LOAD RATED DC DISCONNECT ���y/ CENTER WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS " COMPLIANT S440 (I EXISTING 200A (N)LOCKABLE C� BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY ( SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE 6000 WATT INVERTER JUNCTION BOX PV MODULES METER �\ (4) �4) 3b Cb> OR EQUIVALENT op, TRINA SOLAR:TSM-390DE09C.07 EXISTING I 1. Q A X / (22)MODULES < PA EL — ,,�, O ✓` _ ^� �_ '�// OPTIMIZERS WIRED IN: FACILITY --- (1)SERIES OF(14)OPTIMIZERS LOADS 60A FUSES —� 1 I (1)SERIES OF(8)OPTIMIZERS `o�eoeNo SQUARE D 240V METER SOCKET 20A BREAKER(A) LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS 35A BREAKER(B) WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1a NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n r u n 1b NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2a 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 2b 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 #180120 38 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHWTHWN-2 (1)8 AWG THHN/THWN-2 805 MYLESSTANOISH BL.w,TAUNTON,U&OYr8e-n0I PHONE Pa.o 3b 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 CUSTOMER RESIDENCE AHAB 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 EMAD HIGGINS AGDEL CROWELL CROWELL RD, 5 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 YARMOUTH,MA,02673 W TEL.(617)697-2910 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: APN:YARM-000074-000067 TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V MAX INPUT VOLTAGE: 60 VDC 223R-464WAHA SHORT CIRCUIT CURRENT: 13.35 A MAX INPUT ISC: 14.5 ADC MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)5806920 ex3 ERI DANIEL-KALIO SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM CHARACTERISTICS-INVERTER 2 SYSTEM SIZE: 5460 W SYSTEM SIZE: 8580 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 3/17/2023 SYSTEM OPERATING CURRENT: 14.37 A SYSTEM OPERATING CURRENT: 22.58 A PAGE SYSTEM SHORT CIRCUIT CURRENT: 15 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PV-4,0 T.mMaIe_wraon 40.87 INVERTER 1 NOTES AND SPECIFICATIONS: WARNING PHOTOVOLTAIC DC DISCONNECT •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD MAXIMUM SYSTEM VOLTAGE: 480 VD IFREQUESTED BY THE C •SIGNSRE U AND LABELS SHALL ADEQUAALAHJ.TELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD LABEL LOCATION: WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN IM/ERTER(S).DC DISCONNECT(S). •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION PER CODE(S):NEC 2023,690.7(D) •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVERTER 2 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL OF APPUCABLE). PHOTOVOLTAIC DC DISCONNECT •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:680.13(B), MAXIMUM SYSTEM VOLTAGE 480 T I 705.2op>,706.15(C) NOTICE PV MBINER PANEL LABEL LOCATION:DN: DO NOT ADDrLOAOD LOADS THIS PANEL /WARNING P'R�CODE(S)NEC12023369053(S) DUAL POWER SUPPLY LABEL LOCATION: WARNING: PHOTOVOLTAIC LOAD CENTER PD SOURCES:UTILITY GRID [Onlyuse when applicable for PV lose center AND PV SOLAR ELECTRIC SOURCE SYSTEM POWER LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT. UTIUTY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. CAUTION . PER CODE(S):NEC 2023:705.30(C) PER CODE(S):NEC 2023:690.31(D)(2) AWARN• ING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM T DO NOT RELOCATE THIS ,TNT OVERCURRENT DEVICE LABEL LOCATION: AL LOCATION:ON: INSTALLED R COD ( ,NECF SHUT DOWN s u n r u n ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S),NC 2023:890.12(D)(2),IFC SOLAR PANELS ON ROOF OCPD(IF APPLICABLE). 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(B)(2) 4', A WA IN #180120 SOLAR PV SYSTEM EQUIPPED THIS EQUIPMENT FED BY 695MELBES STANDISH BLVD,.AD on Nr0N.MA,ozreo.r , PH MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN FAX RATING OF ALL OVERCURRENT CUSTOMER RESIDENCE: DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE EMAD ABDEL WAHAB SHALL NOT EXCEED AMPACITY OF MAIN PANEL(INT) 4- INVERTERS(EXT) 464 HIGGINS CR TH, 02 73 RD, BUSBAR AlaiL LABEL LOCATION: 3" TURN RAPID SHUTDOWN PV LOAD CENTER PV LOAD CENTER(IF APPUCABLE)AND SWITCH TO THE"OFF" TEL.(617)697-2910 ANY PANEL THAT UTILIZES'THE SUM POSITION TO SHUT DOWN PRODUCTION APN:YARM-000074-000067 OF CODES) RULE".0 PV SYSTEM AND REDUCE SERVICE ENTRANCE METER PROJECT NUMBER: PER CODE(S):NEC 223:705.12(8)(3) SHOCK HAZARD IN THE FUSED 223R-464WAHA ARRAY. Ell AC DISCONNECT DESIGNER: (415)580-6920 ex3 PV SYSTEM DISCONNECT MAXIMUM AC OPERATING CURRENT:41.00 AMPS 464 HIGGINS CROWELL RD, YARMOUTH, MA, 02673 ERIDANIEL-KALIO NOMINAL OPERATING AC VOLTAGE: 240 VAC SHEETLABEL LOCATION: S I G NAG E ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ' AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ARE CONNECTED. REV'.Al 3/17I2023 INTERCONNECTION. PER CODE(S):NEC 2023:690.12(D) PER CODE(S):NEC 2023:690.54, PAGE PV-5.0 rempare_ee on_.0 sr