Loading...
HomeMy WebLinkAbout137 Run Pond Rd plan003SECOND FLOOR PLAN INTERIOR DOORS SCHEDULE: D1 2'-6" X 8'-0" 02 3'-0" X 8'-0" 20 MIN FIRE RATED D3 2'-4" x 8'-0" 04 4,-0„ x 8, 0„ 3-0' X 8-0 FOR EXTERIOR DOORS AND WINDOWS SEE WINDOW SCHEDULE AND BUILDING ELEVATIONS LEGEND: PHOTO ELECTRIC HARD WIRED SMOKE DETECTOR WITH SECONDARY (STANDBY) POWER SUPPLIED FROM MONITORED BATTERIES FAN/LIGHT TO BE VENTED DIRECTLY TO OUTSIDE © CARBON MONOXIDE DETECTOR HEAT DETECTOR NOTES: 1. ALL EXTERIOR WALLS ARE 2"x6" @ 16" O.C. UNLESS NOTED OTHERWISE. 2. ALL INTERIOR WALLS ARE 2"x4" @ 16" O.C. UNLESS NOTED OTHERWISE. 3. INTERIOR WALLS BETWEEN GARAGE AND THE BUILDING ARE 2"x6" @ 16" O.C. 4. DIMENSIONS TO THE OUTSIDE WALLS ARE TO FACE OF STUDS OR EXTERIOR FACE OF THE FOUNDATION WALL. DATE I REVISION All legal rights including, but not limited to, copyright and design patent rights, in the designs, arrangements and plans shown on this document are the property of RAV&Assoc., Inc. They may not be used or reused in whole or in part, except in connection with this project, without the prio written consent of RAV&Assoc., Inc, Written dimensions on these drawings shall have precedence over scaled dimensions, Contractors shall verify and be responsible for all dimensions and conditions on this project, and RAV&Assoc., Inc. must be notified of any variation from the dimensions and conditions shown by these drawings, • , , • • /•; �k j 137 RUNPOND ROAD, SOUTH L L-1 UTR, MAS>�'AC'�-I USETT,S° 8c Assoc., Inc. 21 HIGHLAND AVENUE NEEDHAM, MASSACHUSETTS 02494 TELEPHONE: (781) 449-8200 FAX: (781) 449-8205 SCALE: 1 /4"=1 ' —0" APPROVED: R.A.V. DESIGNED BY: I.M. DRAWING No, DATE: 01 /05/2023 DRAWN BY: E.F. A— 2 CHECKED BY: R.A.V.