HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out
Acreage
Commercial: Residential:_____Street:
. Village: Floor Plan:
Bedrooms:
Owner: Installer:
Address: Phone:
Phone:
Builder: Engineer:
Address: Phone:
Phone:
1. Required#of copies received I N A YES NO
2. Date of soils exam and percolation test not older than 2 years '
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above hi•h •oint of road Fnd: Var.:
'' 5. Water line 10 ft from septic components Var..
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I i ---
9. Leaching minimum 100 ft from wetlands
10. LeachingVar.: IIIIIIIIMIIIIM
minimum 150 ft from drinking well/25 ft irrigation well Var.:
`''' `y' leaching minimum 10 ft from .ro.ert line Var.:
12. System meets all other setback requirements Var.:
13. Uses ad.ustment for maximum hioh groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewaae is under 10,000 Aid for .arcel - MN
21.No garbage disposal
22. S stem ade uately sized for its intended use
23.Minimum 6"stone or com.acted below tank and dbox _
24. Manhole covers within 6"of a ade, sump chamber cover to grade _
25. Ins.ection .ort on .lastic chambers/leach field1111.1111111111111
26. Electrical .ermit for 'urn. chamber/Se.arate meter for du.lexes
27.Pura. system-2"line,wee. hole,check valve, tee in dbox, .ump size
28. Septic tank/mum. chamber to be facto wate 'roofed1111111.1111111
_11111111111110
29. Vent .rovided if leachin below 3 feet,under driveway/parkin°
30. Buo anc calculations for tank/sums chamber 1111111
31. Engineer to ins.ect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature -��
33.H-20 loading is sub ect to vehicular traffic, : oundwater _IIIIIIIIIIIIIIII
34.T tl- V Aa.lr*11101TraaI.zaualac AMT.f 111k4,., -
1111.111111111111
35.Foundation footing min. 2 feet above ad'usted around water for new house
IIIIIIIIIIIII
36.Deed Restriction required max. #bedrooms: max. flow: ■
37. Check area lots for groundwater/Label oundwater in Assessor's Ma. gPd
1.
•
Plan reviewed by: