Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot /? 1 Zone of Contribution: In_ Out Acreage / Commercial: Residential: i/ Street: .3j C./r��t„v 4 rl Village: Floor Plan:�_s LA 5 -r, :1.... #Bedrooms: ����� I/ c' Installer: 1.7?.4(r. GO� r Owner: r,2A lfl 1dl 0 ri Address: :-97 /;I r-3 51 Phone: 47/3 09 y/- i.- Phone: {} Builder: Engineer: a L,' C9 LI, I1 y 6 L iT /E Co fie et Address: Phone: 55-- 3 t1 - G 5 `3 Phone: N/A YES NO 1. Required#of copies received _=- 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: i/ 5.Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 3,5 l s 9.Leaching minimum 100 ft from wetlands Var.: ✓ 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: v 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: t, 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L 15. System not in top or subsoil(A,B horizons)or 5' removal t, 16. Proposed contours are suitable v 17. System meets slope requirements-min. 1/8", 'A"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee ., 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal `. 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pu -chamberto'be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max.flow: gpd 37. Check area lots for groundwater/Label groundwater' e or's Map Plan reviewed by: / -p7 3 02`( 1 6/03/03 i I I