HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out_ Acreage
Commercial: Residential:
Street: -----
Village: Floor Plan: w'- #Bedrooms: `/
Owner: C Circe I( Installer: (4) &QS
Address: Sc,4-,.4 Phone: •
Phone: �'�' - " 3ba b 3
Builder: Engineer: (0G V+it /. a S L 0
Address: Phone:
Phone: `s�`S j !h
N/A YES NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years ' -3. 4-5 ft of naturally occurring pervious material,above water table ._ _ -
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: /-
5. Water line 10 ft from septic components Var.: ( 17-
6. Benchmark indicated and shown-NGVD if near wetlands
Septic tank minimum 10 ft from foundation, deck Var.: I v
8.Welling minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
T." `ank/leaching minimum 10 ft from property line Var.:
1 12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: v
15. System not in top or subsoil (A,B horizons)or 5' removal ✓/
16. Proposed contours are suitable I i/`
17. System meets slope requirements-min. 1/8", %"preferred N -
__18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee V
20. Sewage is under 10,000 pd for parcel
21.No garbage disposal
22. System adevately sized for its intended use - v
1/
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26. Electrical permit forpump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber • 1-
31.Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: ��' c `�-
•
z*
•
W �
'2
_ _ aY9
..,. 1(0 Js
•
.. -.. - ,
a i,:',