HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out_ Acreage Commercial: Residential: Street: ----- Village: Floor Plan: w'- #Bedrooms: `/ Owner: C Circe I( Installer: (4) &QS Address: Sc,4-,.4 Phone: • Phone: �'�' - " 3ba b 3 Builder: Engineer: (0G V+it /. a S L 0 Address: Phone: Phone: `s�`S j !h N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years ' -3. 4-5 ft of naturally occurring pervious material,above water table ._ _ - 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: /- 5. Water line 10 ft from septic components Var.: ( 17- 6. Benchmark indicated and shown-NGVD if near wetlands Septic tank minimum 10 ft from foundation, deck Var.: I v 8.Welling minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: T." `ank/leaching minimum 10 ft from property line Var.: 1 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: v 15. System not in top or subsoil (A,B horizons)or 5' removal ✓/ 16. Proposed contours are suitable I i/` 17. System meets slope requirements-min. 1/8", %"preferred N - __18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee V 20. Sewage is under 10,000 pd for parcel 21.No garbage disposal 22. System adevately sized for its intended use - v 1/ 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit forpump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber • 1- 31.Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: ��' c `�- • z* • W � '2 _ _ aY9 ..,. 1(0 Js • .. -.. - , a i,:',