HomeMy WebLinkAboutReview Checklist TOWN OF YARh1OUTH
P7cc9(-11- SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In_ Out_ Acreage
Commercial: Residential:_
Street: ii‘.5
_14 Village: 5. y Floor Plan: # Bedrooms:
Owner: SL,n d'�C 21Cd" s o -t ' L� Installer:)'a 1't� D /W6tApliohf/ e c
Address: �;j Tel C.,/. '; r-vN i Phone:
Phone:
Builder: Engineer: f3y �
Address: Phone: 2 - 7-7 v, co 1S
Phone:
N/A YES NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material,above water table i
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: ,
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: --_
�` 9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking welV25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.:
1 12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements- min. 1/8", ''/_"preferred
__18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal -
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6" of grade, pump chamber cover to grade _
25. Inspection port on plastic chambers/leach field
1 26. Electrical permit for pump chamber/Separate meter for duplexes ,
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for-tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house •
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/jabel/groundwater in Assessor's Map
Plan reviewed by: _ /1 o � / . _ 60101
. r
•J