Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARh1OUTH P7cc9(-11- SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In_ Out_ Acreage Commercial: Residential:_ Street: ii‘.5 _14 Village: 5. y Floor Plan: # Bedrooms: Owner: SL,n d'�C 21Cd" s o -t ' L� Installer:)'a 1't� D /W6tApliohf/ e c Address: �;j Tel C.,/. '; r-vN i Phone: Phone: Builder: Engineer: f3y � Address: Phone: 2 - 7-7 v, co 1S Phone: N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material,above water table i 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: , 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: --_ �` 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking welV25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 1 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements- min. 1/8", ''/_"preferred __18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal - 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6" of grade, pump chamber cover to grade _ 25. Inspection port on plastic chambers/leach field 1 26. Electrical permit for pump chamber/Separate meter for duplexes , 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for-tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature , 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house • 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/jabel/groundwater in Assessor's Map Plan reviewed by: _ /1 o � / . _ 60101 . r •J