Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 6 //S-e Zone of Contribution: In_ Out_ Acreage Commercial: Residential:_____Street: Village: Floor Plan: a Bedrooms: Owner: /f ,tiny (7cttt,f ki er Installer: Address: i-i c_Epi s(- -1l,,y Phone: Phone: _ 64 : 5 Builder: Engineer: ;,. Address: Phone: Phone: 1. Required#of copies received N.A YES NO 2. Date of soils exam and percolation test not older than 2 years ' - 3. 4-5 ft of naturally occurring pervious material, above water table -- 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.:5. Water line 10 ft from septic components Var.. 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I -- 9. Lea ching minimum 100 ft from wetlands Va I I t; r.: I 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ' 11.,Tank/leaching minimum 10 ft fromproperty line Var.: 1 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: MMII 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements- min. 1/8", V."preferred v 18. System meets breakout requirements PVC liner: Wall: ✓ 19. Specified tee sizes are proper, gas baffle on outlet tee I 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal IIIIIIMIIII _ 22. System adequately sized for its intended use I 23. Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field _IMIIIIIMIIII 26. Electrical permit for pump chamber/Separate meter for duplexes 11111111111111111 27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofedIIIIIIIIIIIIIIIII =__ 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for-tank/pump chamber 31. Engineer to ins.ect and certify soils: wall: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature commercial: 33.H-20 loading is subject to vehicular traffic, groundwater IIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 34.Title V Ap.lication and .ermit fee, installer signature 1.11.11111111111 35.Foundation footing min- 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: -_ 37. Check area lots for groundwater/Label • oundwater in Assessor's Ma. gPd I Plan reviewed by: I ' ( f -01,,1 ✓%