HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 59,$'± i - FINISH GRADE OVER D-BOX = 63,0't PROPOSED EXTENSION RISER WITH COVER OVER INLET & REMOVABLE WATER -TIGHT COVER OVER OUTLET TO WITHIN 6" OF F.G. RISER TO WITHIN 6" OF FINISHED GRADE FINISH GRADE __[ @ FND. EL.= 59.6'± F.G. OVER TANK EL. = 60.0' - 60.7' i 5" DIA. OUTLET(S) 4" SCHEDULE 40 PVC MIN SLOPE 1% PROPOSED 4" ; 5.6' MAX. t 22 NOTE C SEE SCH. 40 PVC 00' E � i �- 56. SEE NOTE 22 3 MIN. SLOPE 1'0 2 DROP MAXIrOUTLET ! PROVIDE WATERTIGHT 13" 4" PVC IN FOM4„PVCOUTITOS�P)34EPTIC TAN NTRACTOR TO PROVIDE LEACHING FACILITYECIFIED DROP BETWEENoc .ET AND OUTLET CONTRACTOR CONTRACTOR SHAL 6 TEE 56.3T MIN. 56.20' 2' SHALL VERIFY SIZE 48" VERIFY CONDITION OF AND CONDITION OF EXISTING TEES GAS BAFFLE CRUSHED STONE EXISTING SEPTIC AND REPLACE AS OVER MECHANICALLY j O TANK NECESSARY COMPACTED BASE 4.0' 5 OUTLET TO BEINSTALLED ONIA LEVEL SpTAB EX EXISTING 1,000 GALLON CONCRETE SEPTIC TANK NOT TO SCALE I I r II I GARAGE E GC--2 "415j1AN MAIN EX 2-BGC-1 2)LAB-'602± DW5.0 TOF 00 (4^�j 3) SWING -TIES & DIMS. SCALE: 1" = 20' SWING -TIES DESCRIPTION GC-1 GC-2 CORNER OF STONE (1) 18.5' 13.7' CORNER OF STONE (2) 42.4' 22.1' CORNER OF STONE (3) 46.6' 31.0' CORNER OF STONE (4) 26.7' 25.8' N U Q. °+i L0 rf1 d NOTES: i 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. I 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. �I 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE j FIELD PRIOR TO INSTALLING THE SYSTEM, CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. i 5. THE PURPOSE OF THIS PLAN IS FOR THE UPGRADE OF THE EXISTING SEPTIC SYSTEM FOR THE 4455 MAIN STREET DWELLING ONLY. EXISTING SYSTEM FOR THE 1 MAIN STREET DWELLING SHALL REMAIN IN TACT. BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL I 54.00' CROSS_ SECTION VIEW N--;Y :_. NOT TO SCALE ROUTE 6A (MAIN STREET) (STATE HIGHWAY - VARIABLE WIDTH) EDGE OF PAVEMENT 2% N850 56' Im N MAP 356 j� L LOT 3 18,098± S.F. (4455 Main St., `' f Barnstable) I j fe J 54 v MAP 356 LOT 2 MAP 112 LOT 26 53,433t S.F. (1 Main Street, Yarmouth) #1 MAIN ST. a � I' � � EXISTING j / f O 4 BEDROCM f-. DWELLING J� FINISH GRADE OVER CHAMBERS = 63,0' - 61.5' SLOPE @ 2% MIN. OVER SYSTEM TOP OF SAS = 57.00' BREAKOUT EL = 56.50' ­, PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE r - • . r - • -, , .: - _ �, 3i4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE i 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION 2" OF 1/8" TO 1/2" DOUBLE WASHED METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL STONE OR GEOTEXTILE FILTER FABRIC CODE AND ANY APPLICABLE LOCAL RULES. _ _- _ __ _ _. ____- _ 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE PLACE RISER ON ALL DESIGN ENGINEER. CHAMBERS w/ PIPED 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL INLETS TO WITHIN 6" SYSTEM UNLESS OTHERWISE NOTED. OF FINISHED GRADE 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 56.50' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A Sow 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 0 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. o O O oo i 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. 0 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 00 o I FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 4.0 4.83' 4'0 8. ELEVATIONS BASED ON APPROXIMATE MEAN SEA LEVEL (M.S.L.) DATUM. SEE BENCHMARK (n P') LOCATION AND ELEVATION SHOWN ON PLAN. GROUND WATER ELEV= "L5 t 12 83' I 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 2- 500 GALLON CHAMBERS *EL. of Dennis Pond 5' MIN.�(A��(RND vlEtfN THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TYPICAL CHAMBER PROFILE n , TO THE DESIGN ENGINEER. I'-" `-' ' ` -"-- 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING f{ C,� l 1 1 ,""' E I i ' . '. REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM j j\�^} �) S f ! PERC NO. N/A APPROPRIATE AUTHORITY. Y-1- INSPECTOR: Barry Lewis (BOH) 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED MAP 112 LOT 25-2 01'k- OOA r T r , GARAGE / i.i "14r5 P.141N ST. EXISTNG DWELLING / 61XV ��t 4 �A i 'v PROPOSED H-20 DISTRIBUTION BOX Benchmark � � I I SITE PLAN _- SCALE: 1" = 20' PROPOSED TWO (2) 500 GALLON H-20 LEACHING CHAMBERS w/STONE PROPOSED 4" SCH. 40 PVC VENT; EXACT LOCATION PER OWNER I -� UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR I �\� • 20 • ! EVALUATOR: Michael Pimentel, EIT, CSE ; TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. ' • C.S.E. APPROVAL DATE: Oct. 27, 1999 .. , 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. / • • ( DATE: January 4, 2024 .• f(. , 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE !/!Mk� TEST PIT #: 1 MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. • + :1 +•°� ELEV TOP = 61,50, REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, .... l •+• FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). it'll o ELEV WATER = < 51.00, 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN . `° Yam. PERC RATE _ < 2 min./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. 1 l^ ! 1( i DEPTH OF PERC = 42" - 60" ! 16• PROPOSED PROJECT IS LOCATED WITHIN; H i TEXTURAL CLASS: I ASSESSOR'S MAP 356 LOT 3 (TOWN OF BARNSTABLE) '� ASSESSORS MAP 112 LOT 26 (TOWN OF YARMOUTH) 50''\-1a OWNER OF RECORD: THE CAPE COD CORE, LLC L0006 US �. Ll'�Il B /en�tis p0� 4 25 Perc T 6 JNE-li��-;r ? C LOCUS PLAN SCALE: 1" = 1000' 12 ,.YiWY•3 61.00, ADDRESS: 50 SUN HILL ROAD WEST BARNSTABLE MA 02668 FEMA FLOOD ZONE X 58.00' COMMUNITY PANEL # 25001CO559J 17. DEED REFERENCE: BOOK 34678, PAGE 72 56.50' 18. PLAN REFERENCE: P.B. 553, PG. 21 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE APPROVALS ARE REQUESTED FROM 310 CMR 15.221(7): (1.) A 2.6' WAIVER (3.0' - 5.5') FOR THE MAXIMUM COVER OVER THE H-20 D-BOX. 5100, (2.) A 3.0' WAIVER (3.0' - 6.0') FOR THE MAXIMUM COVER OVER THE H-20 SAS. --_I No Mottling, Standing or Weeping Observed 50xO' EXISTING SPOT GRADE I 4455 MAIN STREET DWELLING - - - 50 - - - EXISTING CONTOUR RECEIVED NUMBER OF BEDROOMS (EXISTING) 2 r0� PROPOSED CONTOUR JAN 25 2024 NUMBER OF BEDROOMS (DESIGN) 3 MIN. PER TITLE 5 50 1 PROPOSED SPOT GRADE HEALTH DEPT. DESIGN FLOW 110 GAL/DAY/BEDROOM TOTAL DESIGN FLOW 220 GAL/DAY ! G?tS EXISTING GAS LINE DESIGN FLOW x 200 % = 440 GAUDAY ( - - :i ' I /'',Y -- - EXISTING OVERHEAD UTILITIES USE EXISTING 1,000 GALLON SEPTIC TANK - W -- IN - EXISTING WATER LINE L 1.- EXISTING LANDSCAPED AREA INSTALL 2 - 500 GAL. CHAMBERS W1 STONE r r TEST PIT LOCATION SIDEWALL CAPACITY - garmouth'ilcalt?' Department EXISTING 1,000 GALLON SEPTIC TANK (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.74 GPD/S.F.) = GAL/DAY (25.0' + 12.83') (2) (2') (0.74 GPD/ S.F.) =112.0 GAL/DAY owl •---- PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE Name Date4 BOTTOM CAPACITY PROPOSED H-20 DISTRIBUTION BOX (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAL/DAY PROPOSED 500 GALLON H-20 LEACHING CHAMBER (25.0' x 12.83') (0.74 GPD/S.F.) = 237.4 GAL/DAY I i TOTALS: TOTAL NUMBER OF CHAMBERS 2 TOTAL LEACHING AREA 472.2 SQ.FT. TOTAL LEACHING CAPACITY 349.4 GAL./DAY RESERVED FOR BOARD OF HEALTH USE REV.-- I- --DATE__. I BY _� APP'D. - I - _ DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE >" ur PREPARED FOR I f€'� L. �� ! ROBERT B. OUR CO. INC. ca CHURCH!', JR. - ' CI4 � No. scr,6 OCATED AT 4455 MAIN STREET, BARNSTABLE, MA 1 MAIN STREET, YARMOUTH, MA SCALE: 1 INCH = 20 FT. DATE: JANUARY 24, 2024 0 10 20 40 80 FEET PREPARED BY JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 50$.273.0377 I Drawn By: MCP I Designed By: MCP I Checked By: JLC JOB No. 7486