HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot ;3l 7s - Zone of Contribution: In Out Acreage
Commercial: Residential:
Street: W i,�i k Lv
Village: ve,v,,„,÷ Ad- Floor Plan: # Bedrooms:
Owner: 6,, mile, Installer: c7(;5 gDS
Address: Co wAn',s�lv & ki P' Phone: c k- 3 .... 6a 3
Phone: 7 /-cs 3 6-• 6 Sz/5
Builder: Engineer: Da ; CI 4
v ASov.
Address: Phone: ca g; 563. (6 r 7
Phone:
N/A YES NO
1. Required#of copies received i/
2. Date of soils exam and percolation test not older than 2 years ✓
3. 4-5 ft of naturally occurring pervious material,above water table i/
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,/
5. Water line 10 ft from septic components Var.: V
6. Benchmark indicated and shown-NGVD if near wetlands ✓
7. Septic tank minimum 10 ft from foundation,deck Var.: Li s" r,AIr.4-,.,f ✓
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ,/
9. Leaching minimum 100 ft from wetlands Var.: V
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11. Tank/leaching minimum 10 ft from property line Var.: v
12. System meets all other setback requirements Var.: V.
13. Uses adjustment for maximum high groundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 3'1-0 4/a .,/
15. System not in top or subsoil(A,B horizons)or 5' removal ,.---
16.Proposed contours are suitable 6/
17. System meets slope requirements-min. 1/8", 'A"preferred V
18. System meets breakout requirements PVC liner: Wall: v
19. Specified tee sizes are proper,gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use
23. Minimum 6"stone or compacted below tank and dbox v
24.Manhole covers within 6"of grade,pump chamber cover to grade v
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes .1/4/
27. Pump system -2"line,weep hole,check valve,tee in dbox,pump size V
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking 0,,,,4_., 1 : , .,; V
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V
33.H-20 loading is subject to vehicular traffic,groundwater ✓
34.Title V Application and permit fee,installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundw • ssor's Map
Plan reviewed by: j ,)' C13