Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot ;3l 7s - Zone of Contribution: In Out Acreage Commercial: Residential: Street: W i,�i k Lv Village: ve,v,,„,÷ Ad- Floor Plan: # Bedrooms: Owner: 6,, mile, Installer: c7(;5 gDS Address: Co wAn',s�lv & ki P' Phone: c k- 3 .... 6a 3 Phone: 7 /-cs 3 6-• 6 Sz/5 Builder: Engineer: Da ; CI 4 v ASov. Address: Phone: ca g; 563. (6 r 7 Phone: N/A YES NO 1. Required#of copies received i/ 2. Date of soils exam and percolation test not older than 2 years ✓ 3. 4-5 ft of naturally occurring pervious material,above water table i/ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,/ 5. Water line 10 ft from septic components Var.: V 6. Benchmark indicated and shown-NGVD if near wetlands ✓ 7. Septic tank minimum 10 ft from foundation,deck Var.: Li s" r,AIr.4-,.,f ✓ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ,/ 9. Leaching minimum 100 ft from wetlands Var.: V 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11. Tank/leaching minimum 10 ft from property line Var.: v 12. System meets all other setback requirements Var.: V. 13. Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 3'1-0 4/a .,/ 15. System not in top or subsoil(A,B horizons)or 5' removal ,.--- 16.Proposed contours are suitable 6/ 17. System meets slope requirements-min. 1/8", 'A"preferred V 18. System meets breakout requirements PVC liner: Wall: v 19. Specified tee sizes are proper,gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox v 24.Manhole covers within 6"of grade,pump chamber cover to grade v 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes .1/4/ 27. Pump system -2"line,weep hole,check valve,tee in dbox,pump size V 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking 0,,,,4_., 1 : , .,; V 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V 33.H-20 loading is subject to vehicular traffic,groundwater ✓ 34.Title V Application and permit fee,installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundw • ssor's Map Plan reviewed by: j ,)' C13