HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In ,---Out_ Acreage
) n ? Commercial: Residential: ✓
Street: 8-0 ,.L,1;c R..c'
Village: w y. Floor Plan: ✓ # Bedrooms:
Owner: id Lq ca,,r c1v 5.e r,i / 1.4, Installer: (2, 6, 0
Address: ca_t, av c j Phone: S b Sc- `/7 7- as--7 7
Phone:
Builder: Engineer: Z'A S LA"'✓4 jZL"
Address: Phone: 5 Zj' - jD�, 36 c v
Phone:
N/A YES NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table L/
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: v
5. Water line 10 ft from septic components Var.: ;,
6. Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation,deck Var.: ✓
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V
9. Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11. Tank/leaching minimum 10 ft from property line Var.: ,/
12. System meets all other setback requirements Var.: _ 7
13.Uses adjustment for maximum high groundwater Var.: .✓
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: /
15. System not in top or subsoil(A,B horizons)or 5' removal
16. Proposed contours are suitable V
17. System meets slope requirements-min. 1/8", 'A"preferred V
18. System meets breakout requirements PVC liner: Wall: X ✓
19. Specified tee sizes are proper,gas baffle on outlet tee ,/
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use i
23. Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade,pump chamber cover to grade ✓
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2" line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature /
33. H-20 loading is subject to vehicular traffic,groundwater
34. Title V Application and permit fee, installer si•nature
35. Foundation footing min. 2 feet above a 'usted ground water for new house
36. Deed Restriction required max. #bedrooms:nq max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 1 _Doi- 1 - 6/03/03