HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 20,4't PROPOSED EXTENSION RISER WITH COVER OVER INLET & ,--FINISHED GRADE OUTLET TO WITHIN 6" OF F.G. @ FOUNDATION = 19.0't 21" MIN. ACCESS COVER (TYP.) PROP. SCH. 40 PVC SEWER-N F.G. OVER TANK EL.= 18.3'f 9" MIN. 36" MAX. `PROP. SCH. 40 PVC SEWER 3„ 2" DROP MIN. I�� „ --------------- 3" DROP MAX. 3 9 7/ T1r1 3 J F__ 14" \_16.00' *18.00'f 1-INLET TEE I 1 16.25' 48" OUTLET TEE TEES TO BE CENTERED GAS BAFFLE 7.5' OFFSET TO FND DIRECTLY UNDER RISERS 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE C PROPOSED 1,500 GALLON CONCRETE SEPTIC TANK "CONTRACTOR TO REPLUMB & EXIT HOUSE LENGTH 10'-61 WIDTH 51-8" DEPTH 5'-8" FOUNDATION AT THIS ELEVATION. - , -,.� ,. r..- (Dimensions per -- ;... ACME/Shorey) CONFIRM TOP OF FOUNDATION EL. = 20.41 -" NOT TO SCALE PRIOR TO COMMENCING WORK. SWING -TIES DESCRIPTION HCA HC-2 DC TANK COVER IN (1) 10.6' 24.6' -- TANK COVER OUT (2) 16.4' 23.9' -- CORNER OF STONE (3) 23.0' 27.4' 62.7' CORNER OF STONE (4) 33.1' 32.5' 65.9' CORNER OF STONE (5) 38.6' 20.8' 136.7' CORNER OF STONE (6) 30.5' 11.4' 30.4' rn M M Z Z a J " -\_ CRUSHED STONE \ �..... , � x18.7 \, 0 MAP 58 LOT 80 x18.7 0-_ PROPOSED FIVE ( 5 ) LC-6 LEACHING CHAMBERS w/ STONE PROPOSED DISTRIBUTION BOX NOTES: 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE I PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT i DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF f HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. i 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY I ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. MAP 58 LOT 96 MAP 58 LOT 81 FINISH GRADE OVER D-BOX = ' 18.4 t G REMOVABLE WATER -TIGHT COVER OVER RISER TO WITHIN 6" OF FINISHED GRADE 5" DIA. OUTLET(S) 9" MIN. ( 36" MAX. L=11't PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS (TYP.) - SEPTIC TANK • 4" PVC OUT TO LEACHING FACILITY 12" 6" 15.87' MIN. \- 15.70' 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET 9 PIPES TO BE LAID LEVEL. I CROSS SECTION VIEW j NOT TO SCALE SITE PLAN SCALE: 1" = 10' FINISH GRADE OVER CHAMBERS = 18.0' - 18,9' SLOPE @ 2% MIN. OVER SYSTEM 4" SCHEDULE 40 PVC MIN SLOPE 1% 9„ MIN. TOP OF SAS = 16.33 15.50' 36" MAX. BREAKOUT EL = 16.00' ---�� F o 0 0 0 0 0 00 o 0 0 0 0 0 0 0 2.0:I! 6.0' (TYP) 2.0' ---_ _ - - 7 A AI 14.50' GROUND WATER ELEV.= 10.50' (mottling) 5 - LC-6 GALLONS CHAMBERS 5.0' MIN. REQ'D 4.0' PROP. (See Gen. Note #22) TYPICAL CHAMBER PROFILE 4-,, & � �, . 1 r l e o e J I \ 0 (P \ �� oao \ O e rn e� , I MAP 58 \\ ' I LOT 95 \ I 10,031t S.F. \ e I \ I I °O e 1 I PROPOSED 1,500 GALLON SEPTIC TANK MAP 58 LOT 94 NOT TO SCALE 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 2" OF 1/8" TO 1/2" DOUBLE WASHED STONE OR GEOTEXTILE FILTER FABRIC PLACE RISER ON ALL CHAMBERS w/ PIPED INLETS TO WITHIN 6" OF FINISHED GRADE tt.»r "g� s� 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE - - - - - - - DESIGN ENGINEER. 3. 4 SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN i ELEVATION = 16.00' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF j 0 -- - O THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. � o 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. _ 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. I o oo 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 0 lc(::) 0 ! FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH i LOCUS PLAN • SCALE: 1" = 1000' j NUMBER OF BEDROOMS (EXISTING) 3 j NUMBER OF BEDROOMS (DESIGN) 3 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 330 GAUDAY : DESIGN FLOW x 200 = 660 GAUDAY USE PROPOSED 1,500 GALLON SEPTIC TANK I AND DESIGN ENGINEER. 4.0' 8• ELEVATIONS BASED ON APPROXIMATE MEAN SEA LEVEL (MSL) DATUM. SEE BENCHMARK 3.0' j (TYP .0LOCATION AND ELEVATION SHOWN ON PLAN, 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 11.0' ` THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT j CHAMBERENDVIEWAND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM x _ € APPROPRIATE AUTHORITY. PERC NO. N/A 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED j 'T INSPECTOR: Barry Lewis (BOH) UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR \ EVALUATOR: _Michael _Pimentel, EIT, CSE ; TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. E C.S.E. APPROVAL DATE: Oct. 27, 1999 ! 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. / DATE: January 25, 2024 j 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE TEST PIT #: 1 ' MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, ELEV TOP = 18.00, 4 FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). ELEV WATER = 10.50, ; 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. PERC RATE _ < 2 min./inch r i 1 16. PROPOSED PROJECT IS LOCATED WITHIN: DEPTH OF PERC = 6" - 24" ' ASSESSOR'S MAP 58 LOT 95 iI TEXTURAL CLASS: I OWNS ANNE M AM I Perc 2' B 31 O� \pd C i 9001 INSTALL (5) LC-6 LEACHING CHAMBERS W/ STONE SIDEWALL CAPACITY (LENGTH + WIDTH) (2 SIDES) (1' HIGH) (0.74 GPD/S.F.) = GAL/DAY (34.0' + 11.0') (2) (1') (0.74 GPD/ S.F.) = 66.6 GAUDAY (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY (34.0' x 11.0') (0.74 GPD/S.F.) = 276.8 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 5 TOTAL LEACHING AREA 464.1 SQ.FT. TOTAL LEACHING CAPACITY 343.4 GAL./DAY 110" 120" Fill Loamy Sand 10Yr 5/6 Med. to Fine Sand 2.5Y 6/6 Standing c, 110"V UN OF RECORD. It-- MINGOLELLI, TRUSTEE ADDRESS: 178 KING PHILLIP STREET WEYMOUTH, MA 02190 18.OQ � 17.50' FEMA FLOOD ZONE X i COMMUNITYPANEL# 25001CO587J 1 16.00' 17. DEED REFERENCE: L.C.C. NO. 232323 ° 18. PLAN REFERENCE: L.C. PLAN NO. 33984-A 15.00 i } 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. { 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE, JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER, THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE j APPROVALS ARE REQUESTED FROM 310 CMR 15.211 & 15.212(1): 10.50' 0.) A 4.6' WAIVER (20.0' - 154) FOR THE SETBACK FROM THE SAS TO HOUSE FOUNDATION. (2.) A 2.5' WAIVER (10.0' - 7.5') FOR THE SETBACK FROM THE TANK TO HOUSE FOUNDATION. (3.) A 1.0' WAIVER (5.0' - 4.0') FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. I 8.83, a nn, Permit valid for REPAIR OF SEPTIC SYSTEM i ONLY, due to State and Local septic variances. Board of Health review and approval 'is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. 1 Yarmouth Ilcalt!h Department ; iZAP T., a Name Date x50.0' - - - 50 --- f� - 50 GAS 10001 C7 EXISTING SPOT GRADE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVER HEAD WIRES EXISTING WATER LINE RECEIVED EXISTING LANDSCAPED AREA FEB 0 9 2024 TEST PIT LOCATION HEALTH DEPT, PROPOSED 1,500 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX PROPOSED LC-6 LEACHING CHAMBER ? I REV. DATE BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE gym' CeA OF Mn4 s ` PREPARED FOR Ia JCHN L. i^,� ROBERT B. OUR CO., INC. i, CHUR✓HaIL JR. •� CIViL NO. 418065 { LOCATED AT Alk 31 HARDING LANE L� ? I ! WEST YARMOUTH, MA 02673 ' SCALE: 1 INCH = 10 FT. DATE: FEBRUARY 7, 2024 fps 0 5 10 20 40 FEET ,fir � CF PREPARED BY OWN L. :'� JC ENGINEERING INC. �a CHRs t!'LL JR, �No. 41307 2854 CRANBERRY HIGHWAY r - •� , _ s ! EAST WAREHAM, MA 02538 ..` At 508.273.0377 Drawn By: MCP Designed By: MCP I Checked By: JLC JOB No. 7529