Loading...
HomeMy WebLinkAboutSite Plan 10-18-22DISTANCE VARIES 154" TOTAL TANK LENGTH OUTSIDE WALL TO OUTSIDE WALL TANK WALL' a ' ' • GENERAL NOTES. THICKNESS T AT TOP I Q (3" TYP) O =w o INFLUENT INFLUENT F_ -� (SEE NOT 1) Y O INFLUENT 00 15 SAMPLING PIPE (2" DIA PVC PIPE) la- a SEE NOTE 6 WW TITLE 5 SEPTIC TANK p TANK WALL THICKNESS (NOT TO SCALE) AT BOTTOM 4 1/2" TYP SUE GED ENITRIJCATI N o RA I = C MBER C A BER o (DC) o J \ Z o F- -i o Y w Za 1. PROVIDE MINIMUM 2" DROP WHILE MEETING � a REGULATORY SLOPE REQUIREMENT FROM THE LL U SEPTIC TANK OUTLET PIPE INVERT TO THE INVERT OF - o OI­_ THE INFLUENT PIPE INTO THE NITROE TANK. 2. NITRIDE TANK TOP TO HAVE TWO-24", THREE -12" Q HOLES AND MULTIPLE 4" DIAMETER ACCESS HOLES 00 WITH RISERS AND COVERS FOR MAINTENANCE AND EFFLUENT SAMPLING. -� 3. FOR THE 24" HOLES; PROVIDE 24" DIA. ADS PIPE WITH COVER TO 12" BELOW GROUND SURFACE. BOLTED TO TANK TOP. TO TITLE 5 4. FOR THE 12" HOLES; PROVIDE THREE-12" HOLES WITH SOIL ADAPTER RINGS, RISERS AND COVERS TO 12" BELOW GROUND SURFACE. INSTALL 4" DIA. MONITORING ABSORPTION PIPE (1" BELOW GROUND SURFACE) WITH 6" PLASTIC SYSTEM ROUND BOX AND COVER TO BE FLUSH WITH GROUND ' (SAS) SURFACE. s 5. PROVIDE FOUR-6" DIAMETER PLASTIC ROUND BOXES AND COVERS (NITROE AND SEPTIC TANKS) TO BE ( ) s INSTALLED AT GROUND LEVEL. 6. PROVIDE INFLUENT SAMPLING PIPE (2" DIA.) 6" FROM SEE NOTES 2, 3 AND 4 EDGE OF SEPTIC TANK WALL WITH 6" PLASTIC ROUND W BOX AND COVER AT GROUND SURFACE SEE NOTE 6 I _ GROUND SURFACE (TYP) I 5 1/2" TANK TOP (TYP) ILI INFLUENT (SEE NOTE 1) a w 0 w LL 9 O TITLE 5 SEPTIC o w a TANK ¢ z o (NOT TO SCALE) o ° z DcLO u' ELEV. = 0" TANK BOTTOM THICKNESS 4" TANK WALL THICKNESS AT BOTTOM (4 1/2") TANK WALL THICKNESS AT TOP (3") ** ADDITIONAL DRAWINGS, DETAILS, AND SPECIFICATIONS CAN BE PROVIDED BY KleanTu LLC TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: JAY GARDINER DATE: 7/20/2022 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 1 0" 16' LS 1OYR 3/2 12" B LS 34" 1OYR 5/8 13.2' C PERC MS 1OYR 7/4 132" I I 5' NO GROUNDWATER ENCOUNTERED TOP VIE ' NOT TO SCALE 6" PLASTIC BOX AND COVER WITH 4" SEE NOTE 5 (TYP) MONITORING PIPE; SEE NOTE 5 (TYP) SEE NOTE 3 (TYP) SEE NOTE 5 (TYP) 12" ACCESS HOLE WITH COVER f SEE NOTE 3 (TYP) SEE NOTE 4 (TYP). I I i TO TITLE 5 SOIL ABSORPTION SYSTEM (SAS) 48" STATIC EFFLUENT WATER DEPTH -� 1 SUBMERGED DENITRIFICATION CHAMBER o WO LUQ w 1 = AERATION (DC) CD a a CHAMBER > > w I_ Z W Z (SAC) 10� Z w oLLJ _joLL Wv _j J U-)WvZ D EL. 10.Ot ACME TD6C Y- KI ea nTu LLC CRUSHED AGGREGATE OR APPROVED / MATERIAL (DEPTH TBD-6" MIN); ON LEVEL, ® PLAN AND PROFILE VIEW COMPACTED AND STABLE BASE NITROE WASTE -WATER TREATMENT SYSTEM (WWTS)D SIDE VIEW NOT TO SCALE T-AS2000-H 10 o� OPERATIONS AND MAINTENANCE AGREEMENT / G SHALL BE IN PLACE PRIOR TO ITS USE AND NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-m 6" LOAM & SEED DISTURBED AREAS 5. PIPE JOINTS TO BE MADE WATERTIGHT. (TYP.) 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) COSCH-40 PVC AT 2% MIN. ADJUSTING BLOCKS/H-20 RISER 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE FROM ROOF DRAINS/TRENCH DRAIN MORTAR ALL COMPONENTS (TYP.) STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. \ 4" MIN. PEASTONE °00000 AND MIRAFI 14ONS °o°o 0000000'0000 FABRIC OVER STONE 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY ...-.8000 46" x 38"sd °o°o°0000 BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. .00.000000 H-20 °OOO000Oo o°00000uo 100 GAL 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) o°o°o DRYWELL 0000 oo�000000 `� WIGGIN PRECAST o0000o AND VERIFYING THE LOCATION OF ALL UNDERGROUND &OVERHEAD UTILITIES PRIOR o OR EQUAL TO COMMENCEMENT OF WORK. o�BOS�o�o u °o° 00000 'oo°000°o e0000000°°°°°°°°°°°°°°°°°°°°°°°°°°°°°° o000o, 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. Z 3/4" - 1 1/2" DOUBLE WASHED STONE j 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND 2' MIN. AROUND PIT FILLED WITH CLEAN SAND. CV & 6" UNDER PIT 13. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. ADJ. G.W. EL. 2f DRAIN SECTION 14. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. NOT TO SCALE I 15. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 16. WETLAND FLAGGED BY BRAD HALL OF BLH ENVIRONMENTAL CONSULTING. / 17. BOTH PROPERTIES TO BE COMBINED INTO ONE BUILDING LOT. .b ry CO rK` Y / SHALL BE FOR THE LIFE OF THE SYSTEM PRESENCE OF THE I/A UNIT MUST BE RECORDED ON THE DEED TO THE PROPERTY. / INSTALLATION OF NITRIDE SYSTEM TO BE IN ACCORDANCE / y SYSTEM DESIGN: WITH PLANS AND SPECIFICATIONS OF MANUFACTURER // N� oo� EFFLUENT TESTING SHALL BE REQUIRED AS GARBAGE DISPOSER IS NOT ALLOWED PER TOWN OF YARMOUTH AND TITLE 5 EXISTING 5 BEDROOM DWELLING TO BE REMOVED CON O PROPOSED 4 BEDROOM DWELLING,p DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW / s N SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK AND A 2000 GAL. NitROE TANK LEACHING: SIDES: 2 (40 + 10) 2 (.74) = 148 GPD BOTTOM 40 x 10 (.74) = 296 GPD TOTAL: 600 S.F. 444 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) , WITH 2.25' STONE AT ENDS 5' BETWEEN UNITS AND 2.6' AT SIDES , MA APPROVED DATE BOARD OF HEALTH SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT I" SCALES ACCESS COVERS TO WITHIN 6" OF FIN. GRADE PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE \ TOF - 19.1 17.5' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 RISERS (TYP.) 2'O * 15.0' 1500 GAL H-10 14" 14.61' T1EE SEPTIC TANK TEE 14.36'4.30 NitROE TANK SEE DETAIL GAS BAFFLE .. ABOVE 4' UQ. LEVEL (ACME OR EQUAL) .. oo0 0 0 0 0 0 o O o 0 0 0 0 0 o c o• O o 0 0 0 0 0 0 0 0 0 0 0 0 o 0 a J 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 !..,OOOOOOOn000„O,,O,,OOOOOOOOOnO,.OnO� 00000Doc,000000000000000000000000000000000000 - - oco0�oo�0�0�0�0"000000000�0�0�0�0„0�0�00000. *THE INSTALLER SHALL VERIFY THE 6" CRUSHED STONE OR MECHANICAL LOCATIONS OF ALL UTILITIES AND ALL COMPACTION. (15.221 [2]) BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ( 2.5 % SLOPE MIN.) (2 X SLOPE) FOUNDATION 11 SEPTIC TANK 3' NitROE TANK - DCE #20-4 > 3 • rl � _ _ . I I �� � //� I ♦ � `� �/ ,• ' • ��n / /' ��MINOr"� ,,,rrM�'11 ..ram::..... � � �• j D _x x _x o ho/ x x % STAKED SIL / O FENCE WO K LI M IT LI �G � AND Ip "� AT ALL SYSTEM COMPONENTS SHALL BE ` MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE FILTER FABRIC OVER STONE 2% SLOPE REQUIRED OVER SYSTEM 17.0' ,`P" PATIO DEMOLISH Q� EXISTING G� DWELLING _ FFLR = 6.2 ECK/ PROPOSED h ''M✓ .__,UhFERTILI ED N / CAFE CO LAWN �� ii -_,_ W W- -\ -_ W X W x / REMiAOVE I 19's00 X DRIVE �� I / MAP 61 PARCELS 53+ S A �31,879 S.F. UPLAND II SHE. I A( C B ACOn 2S , �'� �<v 2 A X 4 / � o �� O BLOCKS OR 6" MIN. SUMP PVC MORTAR ALL PRECAST RISERS 12' MIN. INT. DIM. PIPES LE PIPES LE 1ST 2' COMPONENTS H-10 INV'S EL. HE�DS 5' 13.20' ' = BET. SIDES ' 14.03 ®®®® o°o°o°o°o°o° '-°�'0 0 0 0 0 0, �?,O,O= • WATERTEST D BOX FOR LEVELNESS ° ° o ° ° ° ° ° °°°°°°°° °°°°°°°° > o 0 0 0 ®®08 B�® ® B ®ARE ooUo�o °O°O°° oo°o°° o°°°°° 0 o ® ®®- �® ®®�®®®®®®®� ® ®®®® ,000000po °°Oo°O°° O°O°O°O° °°°°°°°° r o 0 0 0 13.95' 1 .78' ° ° o o >°�°0°.°0 °oo° >°O ®lg®8 °° ° ° o°o°o° °°°° °pO°O° ®®®®88®®® - ° ° ° o :°°°°O°o°o .°O°o°°°O °°°° 1120' �n°o°' o ° ° o NOTE: 2" MIN. WALL THICKNESS REQUIRED LH-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST 3/4"-1-1/2" DOUBLE WASHED STONE (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) OVERALL DIMENSIONS TO OUTSIDE OF STONE: 40' X 10' (2 X SLOPE) - 5' ( 2 X SLOPE) H-20 D' BOX 29' - FACILITY LEACHING 5.0' BOTTOM TH-1 NO GROUNDWATER FOUND LEGEN D X 99. 1 EXIST. SPOT ELEV. -[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE ZYY� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING EXIST NG SMA COAS AL BEA TO B MAI NT LOCUS MAP SCALE 1 "=2000't ASSESSORS MAP 61 PARCEL 53 & 54 (TO BE COMBINED) LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 12) AE (EL 11) & ZONE X AS SHOWN ON COMMUNITY PANEL #25001 CO591 J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 40,000 S.F. 31,879 S.F.f 31,879 S.F.t MIN. LOT FRONTAGE 150' 335' 335' MIN. FRONT SETBACK 30' 131' 30.2' MIN. SIDE SETBACK 20' 8.1' 21.6' MIN. REAR SETBACK 20' N/A N/A MAX. BUILDING COVERAGE 25% 9.0% 15.7% MAX. BUILDING HEIGHT 35' 28.2' RIVERFRONT MITIGATION CALCULATIONS: HARDSCAPE 0-100' 100-200' EXISTING: 4783 SF 1514 SF PROPOSED: 420 SF 4457 SF CHANGE: -4363 SF 2943 SF NET REDUCTION IN HARDSCAPE = 1420 SF ITLE 5 SITE PLAN OF #33 & 39 SETH LANE SOUTH YARMOUTH, MA PREPARED FOR JOSEPH & MEREDITH ZONA �kf�AkA OF &fq q DANIEL cy�Nm DANIELA o A. o OJALA " OJALA u' CIVIL q No.40980 o No.46502 410FFss�0 �,e G�STE��O��� �q✓✓OgUftVE�O� ASS/ONAL EaG DATE DANIEL A. OJALA, P.E., P.L.S. DATE: OCTOBER 18, 2022 Scale:1 20 30 40 50 FEET 0 10 off 508-362-4541 I fax 508-362-9880 downcape.com �OWNn cape engineering, iac. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 20- 413