Loading...
HomeMy WebLinkAboutRevised Plan 11.4.22f ..../ s L AAMPLINQ PIPE (,`01APVC: PIPE) FME NQTE 6 TITLE 5 SEPTI TANK (NOT TO SCALE DISTANCE VARIES 154" TOTAL TANK LENGTH OUTSIDE WALL TO OUTSIDE WALL TANK WALL a GENERAL NOTES: 1/ THICKNESS AT TOP (3 TYP) Q =o INFLUENT o � INFLUENT j;EE NOTE 1) O -� NZO aoFa-H ' J O 3 d �w 0 TANK WALL THICKNESS AT BOTTOM " TYP = SUE �RA GED ENITRI�N o D C ETI BR CD /CF A BER o (DC) o W W \ \ -i o _j -► ::E o w Z a 1. PROVIDE MINIMUM 2" DROP WHILE MEETING a REGULATORY SLOPE REQUIREMENT FROM THE U SEPTIC TANK OUTLET PIPE INVERT TO THE INVERT OF -[U- � THE INFLUENT PIPE INTO THE NITROE TANK. o 2. NITROE TANK TOP TO HAVE TWO-24", THREE -12" HOLES AND MULTIPLE 4" DIAMETER ACCESS HOLES =O WITH RISERS AND COVERS FOR MAINTENANCE AND EFFLUENT SAMPLING. -� 3. FOR THE 24" HOLES; PROVIDE 24" DIA. ADS PIPE WITH BE MENEM MENCOVER TO 12" BELOW GROUND SURFACE. BOLTED TO TANK TOP. TO TITLE 5 4. FOR THE 12" HOLES; PROVIDE THREE-12" HOLES WITH ADAPTER RINGS, RISERS AND COVERS TO 12" BELOW SOIL GROUND SURFACE. INSTALL 4" DIA. MONITORING ABSORPTION PIPE (1" BELOW GROUND SURFACE) WITH 6" PLASTIC SYSTEM ROUND BOX AND COVER TO BE FLUSH WITH GROUND ' (SAS) SURFACE. s 5. PROVIDE FOUR-6" DIAMETER PLASTIC ROUND BOXES AND COVERS (NITROE AND SEPTIC TANKS) TO BE INSTALLED AT GROUND LEVEL. 6. PROVIDE INFLUENT SAMPLING PIPE (2" DIA.) 6" FROM EDGE OF SEPTIC TANK WALL WITH 6" PLASTIC ROUND SEE NOTES 2, 3 AND 4 TOP VIEW BOX AND COVER AT GROUND SURFACE. NOT TO SCALE 6" PLASTIC BOX AND COVER WITH 4" SEE NOTE 5 (TYP) MONITORING PIPE; SEE NOTE 5 (TYP) SEE NOTE 6 SEE NOTE 3 (TYP) SEE NOTE 5 (TYP) 12" ACCESS HOLE WITH COVER GROUND SURFACE (TYP) SEE NOTE 3 (TYP) SEE NOTE 4 (TYP). TO TITLE 5 SOIL 5 1/2" TANK ABSORPTION SYSTEM TOP (TYP) (SAS) ..+ r INFLUENT (SEE NOTE 1) °� a EFFLUENT - 48" STATIC _ 0 W L 0 C U) h TITLE 5 SEPTIC o S TANK Q (NOT TO SCALE) o F (0 u ELEV. = 0" BI- TANK BOTTOM THICKNESS 4" TANK WALL THICKNESS AT BOTTOM (4 1/2") TANK WALL THICKNESS AT TOP (3") ** ADDITIONAL DRAWINGS, DETAILS, AND SPECIFICATIONS CAN BE PROVIDED BY KleanTu LLC TEST HOLE LOGS FNGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: JAY GARDINER DATE: 7/20/2022 PERC. RATE _ < 2 MIN/INCH GL�S I SOILS ELEV. 0,$ 4 16' A LS 12" 10YR 3/2 B LS 34" 10YR 5/8 13.2' PERC MS 1OYR 7/4 132" I I 5' NO GROUNDWATER ENCOUNTERED WATER DEPTH O _ -� SUBMERGED f- DENITRIFICATION CHAMBER ' 1 = AERATION (DC) o CHAMBER Dr �� (SAC) Ir Of D ElfLLJ D L�j� J 0 CRUSHED AGGREGATE OR APPROVED MATERIAL (DEPTH :D. ON COMPACTED AND STABLE BASE NITRIDE 0 WASTE -WATER TREATMENT SYSTEM (WWTS) SIDE VIEW NOT • SCALE I _m34000'fllU OPERATIONS AND MAINTENANCE AGREEMENT SHALL BE IN PLACE PRIOR TO ITS USE, AND SHALL BE FOR THE LIFE OF THE SYSTEM PRESENCE OF THE I A UNIT MUST BE RECORDED ON THE DEED TO THE PROPERTY. INSTALLATION OF NITROE SYSTEM TO BE IN ACCORDANCE SYSTEM DESIGN: WITH PLANS AND SPECIFICATIONS OF MANUFACTURER EFFLUENT TESTING SHALL BE REQUIRED AS GARBAGE DISPOSER IS NOT ALLOWED PER TOWN OF YARMOUTH AND TITLE 5 EXISTING 5 BEDROOM DWELLING TO BE REMOVED PROPOSED 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS 0 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK AND A 2000 GAL. NitROE TANK LEACHING: SIDES: 2 (40 + 10) 2 (.74) = 148 GPD BOTTOM 40 x 10 (.74) = 296 GPD TOTAL: 600 S.F. 444 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.25' STONE AT ENDS 5' BETWEEN UNITS AND 2.6' f AT SIDES / APPROVED PROVIDE MIN. 20" DIAM. WATERTIGHT A^^rC•e ^^Ai r2c Tn wrruw c" nr MLI nownr 14.30' 14.36' , MA BOARD OF HEALTH *THE INSTALLER SHALL VERIFY THE 6" CRUSHED STONE OR MECHANICAL LOCATIONS OF ALL UTILITIES AND ALL COMPACTION. (15.221 [2]) BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ( 2.5 % SLOPE MIN.) (2 X SLOPE) FOUNDATION 11 SEPTIC TANK 3' DCE #20-4 > 3 SYSTEM PROFILE (NOT TO SCALE) PRmmnF 61W 7n" nI011 WeTFRTIC:HT 12" MIN. INT. DIM. 13.95' NOTE: 2" MIN. WALL THICKNESS REQUIRED 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (2 X SLOPE) NitROE TANK 5' 24"H-20 CAST IRON GRATE, AREA DRAIN 3" SUMP BLOCK UP D-BOX STYLE DRAIN 24"I.D RISER TO GRADE, MORTAR ALL COMPONENTS 6 LOAM & SEED DISTURBED AREAS (TYP.) 4"OSCH-40 PVC AT 2X MIN. ADJUSTING BLOCKS/H-20 RISER FROM ROOF DRAINS/TRENCH DRAIN MORTAR ALL COMPONENTS (TYP.) ' o`o°°°°o \ °o°o°000° 4" MIN. PEASTONE °° °0 °o°°o°°o°o AND MIRAFI 14ONS 0 0 0 0 0000°0000 0000000°o oo FABRIC OVER STONE 000000000 �" X"� o0000o;o° • °0000000o H-20 °o°°o°°oo°o°°o ° o o ° °o°oo°o°o 100 GAL. o°o°o°g°o 00a o00o n DRYWELL o'o00000o °o°° '� WIGGIN PRECAST °o°°°°°°° °o°°o°°o°o°°o I OR EQUAL °o°°o°°o°°o°°o Z 3/4" - 1 1/2- f DOUBLE WASHED STONE / 2' MIN. AROUND PIT N & 6" UNDER PR ADJ. G.W. EL. 2f DRAIN KUM NOT TO SCALE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE FILTER FABRIC OVER STONE 2% SLOPE REQUIRED OVER SYSTEM BLOCKS OR 140 PVC MORTAR ALL PRECAST RISERS LEVEL 1ST 2' COMPONENTS H-10 INV'S EL. WATERTEST D'BOX FOR LEVELNESS . - -.-f 3/4"-1-1/2" DOUBLE WASHED STONE OVERALL DIMENSIONS TO OUTSIDE OF STONE: 40' X 10' ( 2 X SLOPE) H-20 D' BOX 29' FACILITY LEACHING (3) UNITS REQUIRED 5.0' BOTTOM TH-1 NO GROUNDWATER FOUND NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-m 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTIUTIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACIUTY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. 14. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. 15. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 16. WETLAND FLAGGED BY BRAD HALL OF BLH ENVIRONMENTAL CONSULTING 1/15/2021. 17. BOTH PROPERTIES TO BE COMBINED INTO ONE BUILDING LOT. In,\ LEGEN D 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRNNM LOCUS MAP SCALE 1 "=2000't ASSESSORS MAP 61 PARCEL 53 & 54 (TO BE COMBINED) LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 12) AE (EL 11) & ZONE X AS SHOWN ON COMMUNITY PANEL #25001 CO591 J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 40,000 S.F. 31,879 S.F.f 31,879 S.F.f MIN. LOT FRONTAGE 150' 335' 335' MIN. FRONT SETBACK 30' 131' 30.2' MIN. SIDE SETBACK 20' 8.1' 21.6' MIN. REAR SETBACK 20' N/A N/A MAX. BUILDING COVERAGE 25% 9.0% MAX. BUILDING HEIGHT 35' 28.2' RIVERFRONT MITIGATION CALCULATIONS: HARDSCAPE 0-100' 100-200' EXISTING: 4783 SF 1514 SF PROPOSED: 470 SF 4560 SF CHANGE: -4313 SF 3046 SF NET REDUCTION IN HARDSCAPE = 1267 SF PLANTING SCHEDULE SYMBOL PLANT NAME SIZE QUANT. BEARBERRY (12" O.C.) 3"POT 380 SF ARCTOSTAPHYLOS UW-URSI AMERICAN BEACH GRASS 018" O.C. ,.,,3 MLIF 650 SF AMMOPH/LA HREKIGII TA �I j EASTERN RED CEDAR A/N/PERUS 14RGINIANA 2.5" CAL. 2 LE 5 SITE PLAN OF #33 & 39 SETH LANE SOUTH YARMOUTH. MA PREPARED FOR JOSEPH & MEREDITH ZONA DATE: OCTOBER 18, 2022 REV.: NOVEMBER 4, 2022 (CONSERVATION COMMENTS) Scale:1 "= 20' -N OF Mgss9 DANIEL v 0 10 20 30 40 50 FEET s A. OJALA off 508-362-4541 No. 40980 I fax 508-362-9880 P �OFEss\o Q_' downcape.com 0 SUR'4 dowo cape eagi�eeriag, iac. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 DATE DANIEL A. OJALA, P.E., P.L.S. 20-413