HomeMy WebLinkAboutEngineer PlanBERC TOP OF FOUNDATION ELEV. - 100.00 (ASSUMED) rl. 1. 10 FT. MINIMUM 4' CAST IRON PIPE (OR EQUAL) MINIMUM PITCH .1 /4" PER FT. ELEV. ELEV. LIQUID OUTLET DEPTH TEE 4 FEET 14 INCHES 5 FEET 6 FEET 19 INCHES 24 INCHES 8 FEET 34 INCHES . I} -iCt4 TV 17 LEGEND: EXISTING SPOT ELEVATION x0.0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 0. FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE ra3 TOWN WATER -W-W- CATCH BASIN �O j GAS LINE G CESSPOOL CLEANOUT -�C.O. 20 FT. MINIMUM FROM CELLAR 10 FT. MINIMUM FROM SLAB OR CRAVII `_F•.a.L CONCRETE COVERS 4' SCHFOIJIf_ •IO PVC PIPE MIti. I'Itl.'Ii 1/lb" PER FT. " FLOW LINE10 r r _TMIN. 1 ELEV. 2 0" LEVEL BAFFLE ELEV. 6"I SUMP ELEV.. @ q CAS RIBUT10N ELEV. (TO BE PLACED ON FIRM BASES �0X 1 TO 8E WATER TESTED 1500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO 8E PLACED ON FIRM BASE) 3/4' TO 1 1/2' CLEAN -� r} / rv, r,, r,�.1,y,_ DOUBLE WASHED STONE l f REE OF FINES do SILT SEWAGE DISPOSAL SYS71 li PROFILE NOT TO SCALE GRA ND VIEW DRl VE ►-88.4 L �55. 4 • ■ 9.7` 97.2 7.8 98.3 +1 i- Ji DATE OF SC11 TC �1' I i SOIL TESI Dom! BY B- V+I'NESS10 BY CLEAN SAND G1=;,S�'EfNll✓r. �1;0 J � N()l 1 ELr:V.j_ C LOhtd ANO SEED PERCGLATICH f'..'•.TE _<•_.4 1.11N./IJICH AT ryZ INCHES 2" ''YER OF 1/8" TO 1/2' 1 WASHED STONE VENT NOT REQUIRED - �51 N c01 000000 00C10 ----. , 0 0 0 ° o ° 00000000000 ° ° 41TMI 'o° ° ° 000000013000 a 2'0o Er` to. y. ° ° ° O]OC3000 00CID ° ° ° j � �`, o�`_ � o° o° o o ELEV. c _.._., TH N ORYHELLS /N N j �X Z'LOx24'11 7RENCH'STONE FORMIJON Jt WELL SOIL ABSORPTION ZONE` INDEX SYSTEM (SAS), ADJUST USGS PROBABLE WATER TABLE ELEV. OBSERVED WATER TABLE ( / / ) ELEV. BOTTOM OF TEST HOLE ELEV. _ s_ DCR �v 2r RIM=96.5 --IN94W)=_95 2 ti 1_JNV (OUT)=94.8 - T, ~` L =44. 46'97.7 . 9 . " ' r r> 97.9 M 198.6 1 i 98. ! 98.7 I7 �.✓ .J��•; �.1 ri y• I0 F"_0v r 7.8 PORCH I 1 = y / �, GARAGE j 9B. / 97.5 99.1 96.6 6.3 LOT 5 LANO ur rT :tl.i a 1.3, 891. S. 95.5 96.2 HDPE DRAIN PIPE BA SS Rl VER IN -90.2 ►� � , � � ..1 � Lam. , ' .n h OF Mgss9c,� TANYA yes DAIGNEAULT No. 1095 N r o dI'sTt /c DEPTH HORIZ Cot C,R MOTT. OTHER L J7 I NO WATER ENCOUNTERED AT �� ELEV. DESIGN CALCULATIONS NUMBER OF BEDROOMS 3 D�✓''� 1 �`�- GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW 110 GAL/BR'/DAY X BR.) GAL./DAY REQUIRED SEPTIC TANK CAPACITY 1= GAL. ACTUAL SIZE OF SEPTIC TANK 1 GAL. SOIL CLASSIFICATION I __ DESIGN PERCOLATION RATE _<�� MIN./IN. EFFLUENT LOADING RATE 0,7_ GAL./DAY/S.F. LEACHING AREA _ - SQ. FT. LEACHING CAPACITY (AREA X RATE) 4.GAL./DAY RESERVE LEACHING CAPACITY 1A'""_ GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. B. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON ASSESSORS MAP i_ AS PARCEL !`_1 72M91EUMIED OCT 0 4 2005 ' HEALTH DEPT. APPROVED: BO RD OF HEALTH DATE AGENT Fql BA - ��p. HIGH \ / BASS �G' ' / RIVER PROPOSED SEPTIC DESIGN FOR PROJ: TADCO ENVIRONMENTAL CONSULTANTS 26 COMPASS LANE, DENNIS, MA 02638 (508) 385-2425 DATE 2 'Uc"" SCALE ,� _ 20' JOB NO. r -� REVISED LOCATION MAP REVISED SHEET 1 OF 1 G• \Sff\f'KU✓W-UU\awp1-scs.umY C2005 TADCO