BLDE-23-004676
-44) Commonwealth of Official Use Only 1L ,I Massachusetts Permit No. BLDE-23-004676 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/23/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 101 LAKEFIELD RD Owner or Tenant JOHNSON WILLIAM S Telephone No. Owner's Address JOHNSON PATRICIA A, 101 LAKEFIELD RD, SOUTH YARMOUTH, MA 02664-2962 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install of solar PV system (13 Panels 5.07 KW-DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- 13No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) 4c . I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 U9LnJs QLD)1-0) l Please email permitaa to eastmapermits@sunrun.com_ x. Commonwealth ofa�achuda( Official Use Only/ R _ �`�7-467� r _ 's_1 cc77 Permit No. �I— epartmenl'ol..tire Serviced it - Occupancy and Fee Checked o UI"-BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07) t (leave blank) BUILDIN APPA'TION FOR PERMIT TO PERFORM ELECTRICAL WORK All wor to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 02/20/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 101 Lakefield Rd Owner or Tenant William Johnson Telephone No. (774) 994-2108 Owner's Address 101 Lakefield Rd Yarmouth MA 02664 Is this permit in conjunction with a building permit? Yes V1 No (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps / Volts Overhead I‘.4 Undgrd g n No.of Meters 1 New Service Amps / Volts Overhead I I Undgrd I I No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar. 13 solar panels at 5.07 Kw DC. NO ESS. NO STRUCTURAL. Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners (FIRE ALARMS INo.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices Tot No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump I Number I Tons I KW No.of Self-Contained Totals: i Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal Connection ❑ Other No.of Dryers Heating Appliances KW Security Systems:* No.of Water No.of Devices or Equivalent No.of No.of Heaters KW Data Wiring: Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: $6672 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. / LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature 19 LIC.NO.:21136 A (If applicable, enter "exempt"in the license number line.) Address: 695 Myles Standish Blvd. Taunton, MA 02780 Tel.No.:But.Tel.No.:978 793-78817978 *Per M.G.L. c. 147,s.57-61,security work requires Department of Public Safety"S"License: Alt.Lie No. s7e OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $ I Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:5070W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), PV-1.0 COVER SHEET SE SERVICE ENTRANCE •MODULES:(13)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. MP MAIN PANEL SE3800H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL •MAIN PANEL REPLACEMENT:EXISTING 125 AMP MAIN SP SUB-PANEL PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE _ WITH NEW 200 AMP MAIN PANEL WITH 200 AMP MAIN GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. BREAKER. LC PV LOAD CENTER •SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •NEW 200A MAIN BREAKER DISCONNECT WITH 2O0A MAIN •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER ENCLOSURE TO BE INSTALLED •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PV PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). OAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). -*'C.OF ylss'e, or ROBERT A. t DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 4 LADE O DC DISCONNECT(S) C CIVIL •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. J No. 57978 H .2,Exp 6re02024,- CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. a •Eli+ •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). r ,a•... ABBREVIATIONS CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT ,,AMPED 02.21,2023 A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT - S u n r u n AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (E) EXISTING FLUSH ATTIC VENT VICINITY MAP eaS uvLEs srANDlsw aovD rAUNray MA.027e0-733l ESS ENERGY STORAGE SYSTEM PVC PIPE VENT PHONE 0 EXT EXTERIOR METAL PIPE VENT , INT INTERIOR CUSTOMER RESIDENCE: WILLIAM JOHNSON MSP MAIN SERVICE PANEL - T-VENT Whltes Path 101 LAKEFIELD RD,YARMOUTH, (N) NEW C/ MA,02664 NTS NOT TO SCALE - SATELLITE DISH P`lf K'PstN A TEL.(774)994-2108 OC ON CENTER FIRE SETBACKS APN:YARM-000078-000195 louse Rd PROJECT NUMBER. PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT Hbah*W1 223R-101 JOHN HARDSCAPE PV PHOTOVOLTAIC - DESIGNER: (415)580-6920 ei3 RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE AUXILIE UWIDUHAYE TL TRANSFORMERLESS SOLAR MODULES110 SCALE:NTS TYP TYPICAL ---r SHEET 101 Lakefield Rd, 1 a V VOLTS South Yarmouth,MA REV NAME DATE COMMENTS COVER SHEET o s W WATTS ! 02664,United States 9� � Baas RIYBI REV:A 2/21/2023 LAN LANDSCAPE SNR MOUNT PAGE POR PORTRAIT SNR MOUNT&SKIRT cA� South PV-1.0 - - - Templare_ve mon_4.0.8T SITEPLAN-SCALE=1/16"=1'-0" \(01I (E)DETACHED PL STRUCTURE • - PL -- _ a PL a ` r-------- \:°'' r-(151 PM O SE a. INV ° P I. GV`HOFy4s. • °a. t ROBERT A. t 4' f_ \ an LADEa No.57978 \ .,.- , ' _ Exp:6000024 0- STAMPED 02/21/2023 r„ sunrun (N)ARRAY AR-01 d #180120 BB5 MOLES BTANDSH BLW,TAUNTON,MA,027067331 (E)RESIDENCE '17O CUSTOMER RESIDENCE: WILLIAM JOHNSON 101 LAKEFIELD RD,YARMOUTH, MA,02664 TEL.(774)994-2108 APN:YARM-000078-000195 Pt- ARRAY TRUE MAG PV AREA PROJECT NUMBER: Pi- - PITCH AZIM AZIM (SQFT) 223R-101JOHN - -- AR-01 23° 149° 163° 269 DESIGNER: (415)580.8920 ex3 AUXILIE UWIDUHAYE SHEET SITE PLAN REV A 2/21/2023 PAGE PV-2.O 7 9435_,+r2on_4017 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 9'-2" 18" 6'-0" 2'-4" 3'-0" 1'-6" STAGGERED 140 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREW 5/16":2.5"MIN.EMBEDMENT D1-AR-01-SCALE:3/16"=1'-0" INSTALLERS SHALL NOTIFY ENGINEER OF ANY AZIM:149° POTENTIAL STRUCTURAL ISSUES OBSERVED PITCH:23° PRIOR TO PROCEEDING W/INSTALLATION. IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: "ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. SA OF 1,0 s 4'� 9c 40'8" • 5'-10" 2 ti LADE ROBERT A. � c�i CIVIL ti No. 57978 .q, Exp.6/30rz024 0 IT •.• !.: • STAMPED 02i21'202:3 T-3" ❑ ❑ C• ❑ 1 sun r u n 6'TYP - + — 0 v 0 #180120 3, •. BPS mvLes STANDISH e!vo,wm*em Mn ane,aa: • Aopea • CUSTOMER RESIDENCE: • WILLIAM JOHNSON 101 LAKEFIELD RD,YARMOUTH, 34'-10" 11'-8" < MA,02664 TEL.(774)994-2108 APN:YARM-000078-000195 PROJECT NUMBER: 223R-101 JOH N DESIGNER: (415)580-6920 ex3 AUXILIE UWIDUHAYE SHEET LAYOUT REV:A 2/21/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 Tempete_va n_a 0.87 ° J. 120/240 VAC SINGLE PHASE SERVICE M O METER#: EVERSOURCE 23727443 UTILITY GRID NEW 200A MAIN /i BREAKER I\ DISCONNECT 1 IMTH 2O0A MAIN NOTE:TOTAL PV BACKFEED-20A ENCLOSURE USED FOR INTERCONNECTION CALCULATIONS (1 NEW 200A MAIN BREAKER I i1 NEW 200A (N)MA SMART ` MAIN PANEL (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES: BLADE TYPE REVENUE SE3800H-USSN FACILITY "' — AC DISCONNECT LOADS ^ 0 METER © 3800 WATT INVERTER JUNCTION SOX OR EQUIVALENT PV MODULES \JTRINA SOLAR:TSM-390DE09C.07 ' ® ' 1 0 // (13)MODULES �• ' M , ---. ' , *71j/ OPTIMIZERS WIRED IN: `Y (1)SERIES OF(13)OPTIMIZERS FACILITY (I)20A SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT .Ir- PV BREAKER AT DU221RB 100A CONTINUOUS WTH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT S440 OF BUSBAR 120/24OVAC CONNECTS TO TOP 1.1.108• (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHWTHWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 BOB MYLES STANDISH BLVD,TAUNTON,MA,02780.7331 PHONE 0 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: P"° TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 80 VDC CUSTOMER RESIDENCE: MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC WILLIAM JOHNSON SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC 101 LAKEFIELD RD,YARMOUTH, MA,02664 SYSTEM CHARACTERISTICS-INVERTER 1 TEL.(774)994-2108 SYSTEM SIZE: 5070 W APN:YARM-000078-000195 SYSTEM OPEN CIRCUIT VOLTAGE: 13 V SYSTEM OPERATING VOLTAGE: 380 V PROJECT NUMBER: 223R-101 JOHN MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 13.34 A DESIGNER: (415)580-6920 ex3 SYSTEM SHORT CIRCUIT CURRENT: 15 A AUXILIE UWIDUHAYE SHEET ELECTRICAL REV:A 2/21/2023 PAGE PV-4.0 TemplAte_ve n_A 0.87 /\WARNING INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(8),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:690.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.1 3(B), WARNING: PHOTOVOLTAIC 705.20(7),),706 708.15(5(C) POWER SOURCE /!TWA RN I N G LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SOURCES:UTILITY GRID ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:690.31(D)(2) AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: CAUTION : ' UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2023:705.30(C) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT , ii CONNECTION FOR SOLAR PV SYSTEM SOLAR PANELS ON ROOF-1 (1/0 DO NOT RELOCATE THIS - _ OVERCURRENT DEVICE LABEL LOCATION: AJAL LOCATION:ON: INSTALLED WITHIN( :OF RAPIDNC 0 :890.DOWN $u n r u n ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:890.12(D)(2),IFC OCPD(IF APPLICABLE). 2018:1204.5.3 n PER CODE(S):NEC 2023:705.12(B)(2) MAIN PANEL AND A WARNING ' SOLAR PV SYSTEM EQUIPPED PV BREAKER s160l20 THIS EQUIPMENT FED BY DISCONNECT BIM MYLES STAND..BLVD,TAUN CN,MA 02 7 9 0.13 31 MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN (INT) I PHONEI RATING OF ALL OVERCURRENT L CUSTOMER RESIDENCE: DEVICES EXCLUDING MAINDEVI INVERTER (EXT) N4LLIAM JOHNSON SUPPLY DEVICES DEVICE 101 LAKEFIELD RD,YARMOUTH, SHALL NOT EXCEED AMPACITY OF LABEL LOCATION: BUSBAR 3" TURN RAPID SHUTDOWN SERVICE —PV PRODUCTION METER MA,02664 PV LOAD CENTER(IF APPLICABLE)AND SWRCH TO THE"OFF" ENTRANCE AC DISCONNECT TEL.(774)994-2108 ANY PANEL THAT UTILIZES"THE SUM POSITION TO SHUT DOWN APN:YARM-000078-000195 OF BREAKERS RULE". PV SYSTEM AND REDUCEal PROJECT NUMBER: PER CODE(S):NEC 2023:705.12(B)(3) NUM SHOCK HAZARD IN THE OHN PV SYSTEM DISCONNECT ARRAY. MAXIMUM AC OPERATING CURRENT 16.0 AMPS DESIGNER: (415)580.8920 ez3 NOMINAL OPERATING AC VOLTAGE: 240 VAC 101 LAKEFIELD RD, YARMOUTH, MA, 02664 AUXILIE UWIDUHAYE SHEET LABEL LOCATION: LABEL LOCATION: SIGNAGE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):NEC 2023:690.54,CEC 2022:690.54 ARE CONNECTED. REV:A 2/21/2023 PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.0 TemAate_ve 0 4.0.87