Loading...
HomeMy WebLinkAboutBLDE-23-004677 Commonwealth of official use only Massachusetts Permit No. BLDE-23-004677 .4.' k:41: BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/23/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 256 LONG POND DR Owner or Tenant BOULETTE CHRISTINE C Telephone No. Owner's Address BOULETTE SHANE M, 256 LONG POND DRIVE, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes ❑ No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (28 Panels 10.92 KW-DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tons Tota No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Eauivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring: y g No.of Devices or Equivalent • OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. +A,/ r CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) x V �/� I certify,under the pains and penalties of perjury,that the information on this application is true and complete. — _ �! FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Cc4NC ) Please email permit to eastmapermits@sunrun.com K ,'C E t: iy CommonwealthOfficial Use Only o ao�ac uaetta * y- cc�� Permit No. e...7.3 —4 1:7 7 pal= .De artmment o f ire�arviceo E FEBF l — -- �9y. OARD OF FIRE PREVENTION REGULATIONS [Rev.O 1p/07] and Fee Checked } 3UiLDING DEP 'r` =N7 ) (leave blank) I By.---------APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 02/21/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)256 Long Pond Dr Owner or Tenant Christine Boulette Telephone No. (774)212-1713 Owner's Address 256 Long Pond Dr Yarmouth MA 02664 Is this permit in conjunction with a building permit? Yes V No n (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 200 Amps / Volts Overhead N I Undgrd No.of Meters 1 New Service Amps / Volts Overhead _ Undgrd Ti No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar.28 solar panels at 10.92 Kw DC. NO ESS. NO STRUCTURAL. Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Detection and No.of Switches No.of Gas Burners Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: $14,371.00 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al lLt Licensee: Nathan Ashe Signature LIC.NO.:21136 A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978 793-7881 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one) ❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE.10920W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SE SERVICE ENTRANCE •MODULES.(28)TRINA SOLAR.TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 PV-3.0 LAYOUT •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). OAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 4���tNOF MgsS'�y o ROBERT A. • DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. LADE O DC DISCONNECT(S) S NDCI57978 ,;, •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. Esp 6/302024,4R CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. �D``r • ; •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). ..(, ' ABBREVIATIONS T 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE STAMPED 02/20/2023 A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY su ru AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 IEI EXISTING FLUSH ATTIC VENT VICINITY MAP ESS ENERGY STORAGE SYSTEM PVC PIPE VENT PH MVLE55rANDISH eI.w.rAUNfCN.raA bt]a613N DA'Tn15 FAX EXT EXTERIOR METAL PIPE VENT NT NTERIOR CUSTOMER RESIDENCE: IMSP MAIN SERVICE PANEL CHRISTINE ROULETTE T-VENT 256 LONG POND DR, IN) NEW SATELLITE DISH �� YARMOUTH,MA,02664 NTS NOT TO SCALE Ydff710Uth South Dennis TEL.(774)212-1713 OC ON CENTER FIRE SETBACKS ' . APN:YARM-000059-000105 PRE-FAB PRE-FABRICATED PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT I ' HARDSCAPE . West I- 223R-256BOUL PV PHOTOVOLTAIC "• - _ —PL— PROPERTY LINE DESIGNER' (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE ,---SOLAR MODULES ENOCK KWIZERA TL TRANSFORMERLESS SCALE:NTS Ix ,,,,, TYP TYPICAL SHEET 256 Long Pond D►, REV NAME DATE COMMENTS COVER SHEET V VOLTS " 5outh)Yarnwuth;FAA" Dennis POI W WATTS11:1, Ills U. 02664,United States t • REV:A 2/20/2023 LAN LANDSCAPE ' TOPSPEED _.� • • _ PAGE PV-1.0 4:». � POR PORTRAIT MOUNT t u'#-.1, ',"s' _., t s,. remparo ve a 0.87 c� i 23----00/1677 SITE PLAN-SCALE=3/64"=1'0" 1'►:1 rMPW ''''' '-\ a 0 .... :...'. ' \ (E)RESIDENCE 4 ra • 040113 ,., .4. , g 5 CIVIL 0 STAMPED 02/20I202 3 %•o. sunrun • .p. #180120 8G8 MYLES BINiOMM BLVD,,TAUN70N,MA 027804331 / PHONE 0 (N)ARRAY AR-01-- FAX CUSTOMER RESIDENCE: p.. CHRISTINE BOULETTE / 256 LONG POND DR, YARMOUTH,MA,02664 1 T EL.(774)212-1713 \.7 d" APN:YARM-000059-000105 PROJECT NUMBER: 223R-256BOUL DESIGNER: (415)580-8920 ex3 ARRAY TRUE PV AREA ENOCK KWIZERA PITCH AZIM (SQFT) SHEET AR-01 22° 146° 579.4 SITE PLAN REV:A 2/20/2023 PAGE PV-2.0 7.mplate_v n_40.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Edge Overhang Overhang SNOW LOAD:30 PSF Detail WIND SPEED: AR-01 COMP SHINGLE- 1-Story 2X6 TRUSS 16'-1" 16" TOPSPEED,SEE DETAIL SNR-DC-30004 3 1'-5" 0'-10" 141 MPH 3-SEC GUST. TOPSPEED S.S.LAG SCREW D1-AR-0R-01-SCALE:1/8"=1'-0" (4)#14 X 2.25"SS SEALING D A WASHER WOOD SCREWS FULLY PITCH: 6° PENETRATING THROUGH WOOD DECK 56'-1° ' ��p�,'lH OF R4ys, 2'-3"/—• 11'-7" • 15'-0" 29' •-}1'-6" INSTALLERS SHALL NOTIFY ENGINEER OF ANY o' ROLADE A. \ POTENTIAL STRUCTURAL ISSUES OBSERVED 3 ADL � CIVIL �, PRIOR TO PROCEEDING W/INSTALLATION. No. 57978 i q e sreorzo2a 2'9" MOUNT NUMBER FOR LEADING DOWNSLOPE �i� ` EDGE SHALL MATCH REQUIREMENTS LISTED ABINS AL INSTALLATIONPERN TOPSPEEDTM 0 20°23 INSTALLATION MANUAL. STAMPED 02/20/2023 T1 -CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK MOUNTS(SNR DETAIL 14'I 7" ` SNR-DC-00453)WITH A MAX OVERHANG OF 6• s u n r u n J 9,r, #180120 q o o --8-0- -.1 �O,i !B5 MYLES STANDISH BLVD,TAUNTON,LIAR 02780,331 4- Foo 0 1 11'-T' 13-ll'J 23'-2" , 18'-11" / CUSTOMER RESIDENCE: CHRISTINE BOULETTE 256 LONG POND DR, 38'-8" • YARMOUTH,MA,02664 TEL.(774)212-1713 APN:YARM-000059-000105 PROJECT NUMBER: 223R-256BOUL DESIGNER: (415)580-6920 ex3 ENOCK KWIZERA SHEET LAYOUT REV.A 2/20/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 Templete_verslo°40.67 0 120/240 VAC SINGLE PHASE SERVICE METER#: NOTE:TOTAL PV BACKFEED=40A K O EVERSOURCE 2389857 USED FOR INTERCONNECTION UTILITY CALCULATIONS GRID I SUPPLY SIDE TAP c (I EXISTING 200A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: 1 DISCONNECT REVENUE SE7600H-USSN METER 7600 WATT INVERTER /� JUNCTIONRO SOX T PV MODULES i� A A `L J `1 J TRINA SOLAR:TSM-390DE09C.07 �\ EXISTING z /, (28)MODULES 200A MAIN • ,�,oe I O a—w� �— �_ ) *V., OPTIMIZERS WIRED IN: FACILITY — PANEL (1)SERIES OF(14)OPTIMIZERS 40A FUSES I a I (1)SERIES OF(14)OPTIMIZERS LOADS SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (UNE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 8e8 MYLES STANDISH BLVD,TAUNTON,MV,02 7 8 0.73 31 PHONED FAX 0 CUSTOMER RESIDENCE: CHRISTINE BOULETTE 256 LONG POND DR, YARMOUTH,MA,02664 MODULE CHARACTERISTICS TEL. 774)212-1713 S440 OPTIMIZER CHARACTERISTICS: APN:(YARM o00059 000105 TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 223R-256BOUL SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 ENOCK KWIZERA SYSTEM SIZE: 10920 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 27.3 A REV:A 2/20/2023 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 iempare_ve on J.0.87 AWA R N I N G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE ELECTRICAL SHOCK HAZARD fr PHOTOVOLTAIC DC DISCON - 110,21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR -"- " IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 'VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT X PER CODE(S):NEC 2023:690.53,CEC 2022:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B),CEC 2022:690.13(B) AWARNING DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC POWER SOURCE __— SYSTEM i LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, CAUTION . SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:705.12(C),CEC PER CODE(S):NEC 2023:890.31(D)(2),CEC 2022: 2022:705.12(C) 690.31(D)(2) ■ AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS FOR SOLAR PV SYSTEM / \ I� OVERCURRENT DEVICE ) SOLAR PANELS ,�� ADJACENT TO ON: LABEL LOCATION: ON ROOF S u n run ADJACENT TO PV BREAKER AND ESS INSTALLED WITHIN 3'OF RAPID SHUT DOWN J • SWITCH PER CODE(S):NEC 2023:690.58(C)(2), --- - - OCPD(IF APPLICABLE). CEC 2022:690.56(C)(2),IFC 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(B)(3)2), I CEC 2022:705.12(6)(3)(2) 4^ Y A WARNING SOLAR PV SYSTEM EQUIPPED MAIN PANEL(INT) #180120 THIS EQUIPMENT FED BY 595 MYLES STANDISH DLVD,TAUNTON,MA.0ne0a001 MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN /\ PHONEa FAX RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE v." CHRISTINE ROULETTE SHALL NOT EXCEED AMPACITY OF 256 LONG POND DR, BUSBAR YARMOUTH,MA,02664 LABEL LOCATION: 3" TURN RAPID SHUTDOWN PV LOAD CENTER(IF APPLICABLE)AND SWITCH TO THE"OFF" ry• •u SERVICE ENTRANCE TEL.(774)212-1713 ANY PANEL THAT UTIUZES"THE SUM I POSITION TO SHUT DOWN APN:YARM-000059-000105 OF BREAKERS RULE". PV SYSTEM AND REDUCE FUSED AC DISCONNECT PER CODE(S):NEC 2023:705.12 PROJECT NUMBER: (B)(3)(3),CEC 2022:705,12(B)(3)(3) I SHOCK HAZARD IN THE INVERTER (EXT)— PV PRODUCTION 223R-256BOUL ARRAY. MI I METER PV SYSTEM DISCONNECT DESIGNER: (415)580-6920 ex3 MAXIM UMACOPFRATING CURRENT:32.00AMPS 256 LONG POND DR, YARMOUTH, MA, 02664 ENOCKKWIZERA NOMINAL OPERATING AC VOLTAGE: 240 VAC -- SHEET LABEL LOCATION: PER CODE(S):NEC 2023:705.10,710.10,CEC 2022:705.10,710.10 SIGNAGE LABEL LOCATION: ON ORR NO MORE THAT 1 M(3 FT)FROM THE SERVICE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. REV:A 2/20/2023 PER CODE(S):NEC 2023:690.54. PER CODE(S):NEC 2023:690.56(C),CEC 2022:690.56(C) PAGE PV-5.0 Tamp•%vrdon_4.0.87