HomeMy WebLinkAboutBLDE-23-004677 Commonwealth of official use only
Massachusetts Permit No. BLDE-23-004677
.4.' k:41:
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/23/2023
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 256 LONG POND DR
Owner or Tenant BOULETTE CHRISTINE C Telephone No.
Owner's Address BOULETTE SHANE M, 256 LONG POND DRIVE, SOUTH YARMOUTH, MA 02664
Is this permit in conjunction with a building permit? Yes ❑ No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (28 Panels 10.92 KW-DC)(NO ESS)
Completion of the following table may be waived by the Inspector of Wires.
No.of Total
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Tons Tota No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Eauivalent
No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring:
y g No.of Devices or Equivalent •
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office. +A,/ r
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) x V �/�
I certify,under the pains and penalties of perjury,that the information on this application is true and complete. — _ �!
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
Cc4NC )
Please email permit to eastmapermits@sunrun.com
K ,'C E t: iy CommonwealthOfficial Use Only
o ao�ac uaetta
* y- cc�� Permit No. e...7.3 —4 1:7 7
pal= .De artmment o f ire�arviceo
E
FEBF l — -- �9y. OARD OF FIRE PREVENTION REGULATIONS [Rev.O 1p/07] and Fee Checked
}
3UiLDING DEP 'r` =N7 ) (leave blank)
I By.---------APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 02/21/2023
City or Town of: Yarmouth To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)256 Long Pond Dr
Owner or Tenant Christine Boulette Telephone No. (774)212-1713
Owner's Address 256 Long Pond Dr Yarmouth MA 02664
Is this permit in conjunction with a building permit? Yes V No n (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service 200 Amps / Volts Overhead N I Undgrd No.of Meters 1
New Service Amps / Volts Overhead _ Undgrd Ti No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Installation of a interconnected, roof mounted, photovoltaic solar.28 solar panels at 10.92 Kw DC. NO ESS. NO STRUCTURAL.
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Detection and
No.of Switches No.of Gas Burners Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired, or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $14,371.00 (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al
lLt
Licensee: Nathan Ashe Signature LIC.NO.:21136 A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519
Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978 793-7881
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one) ❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
Please email permit to eastmapermits@sunrun.com
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE# DESCRIPTION •SYSTEM SIZE.10920W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),
SE SERVICE ENTRANCE •MODULES.(28)TRINA SOLAR.TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION
PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS.
PV-2.0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023.
MP MAIN PANEL •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004
PV-3.0 LAYOUT •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023.
PV-4.0 ELECTRICAL SP SUB-PANEL
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM DEDICATED PV METER
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
OAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 4���tNOF MgsS'�y
o ROBERT A. •
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
LADE
O DC DISCONNECT(S) S NDCI57978 ,;,
•13.35 AMPS MODULE SHORT CIRCUIT CURRENT. Esp 6/302024,4R
CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. �D``r • ;
•PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). ..(, '
ABBREVIATIONS T 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE STAMPED 02/20/2023
A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY su ru
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT
#180120
IEI EXISTING FLUSH ATTIC VENT
VICINITY MAP
ESS ENERGY STORAGE SYSTEM PVC PIPE VENT PH MVLE55rANDISH eI.w.rAUNfCN.raA bt]a613N
DA'Tn15 FAX
EXT EXTERIOR METAL PIPE VENT
NT NTERIOR CUSTOMER RESIDENCE:
IMSP MAIN SERVICE PANEL CHRISTINE ROULETTE
T-VENT 256 LONG POND DR,
IN) NEW SATELLITE DISH �� YARMOUTH,MA,02664
NTS NOT TO SCALE Ydff710Uth
South Dennis TEL.(774)212-1713
OC ON CENTER FIRE SETBACKS ' . APN:YARM-000059-000105
PRE-FAB PRE-FABRICATED
PROJECT NUMBER:
PSF POUNDS PER SQUARE FOOT I ' HARDSCAPE . West I- 223R-256BOUL
PV PHOTOVOLTAIC "• - _
—PL— PROPERTY LINE DESIGNER' (415)580-6920 ex3
RSD RAPID SHUTDOWN DEVICE ,---SOLAR MODULES
ENOCK KWIZERA
TL TRANSFORMERLESS SCALE:NTS Ix ,,,,,
TYP TYPICAL SHEET
256 Long Pond D►, REV NAME DATE COMMENTS COVER SHEET
V VOLTS " 5outh)Yarnwuth;FAA" Dennis POI
W WATTS11:1, Ills U. 02664,United States t • REV:A 2/20/2023
LAN LANDSCAPE '
TOPSPEED _.� • • _ PAGE PV-1.0
4:».
�
POR PORTRAIT MOUNT t u'#-.1, ',"s' _., t s,.
remparo ve a 0.87
c� i 23----00/1677
SITE PLAN-SCALE=3/64"=1'0"
1'►:1
rMPW ''''' '-\
a
0
.... :...'. ' \
(E)RESIDENCE
4 ra • 040113
,.,
.4.
, g 5 CIVIL
0
STAMPED 02/20I202 3
%•o.
sunrun
•
.p. #180120
8G8 MYLES BINiOMM BLVD,,TAUN70N,MA 027804331
/ PHONE 0
(N)ARRAY AR-01-- FAX
CUSTOMER RESIDENCE:
p.. CHRISTINE BOULETTE
/ 256 LONG POND DR,
YARMOUTH,MA,02664
1
T EL.(774)212-1713
\.7 d" APN:YARM-000059-000105
PROJECT NUMBER:
223R-256BOUL
DESIGNER: (415)580-8920 ex3
ARRAY TRUE PV AREA ENOCK KWIZERA
PITCH AZIM (SQFT) SHEET
AR-01 22° 146° 579.4 SITE PLAN
REV:A 2/20/2023
PAGE PV-2.0
7.mplate_v n_40.87
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Max OC Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF
Name Type Height Type Span Spacing Edge Overhang Overhang SNOW LOAD:30 PSF
Detail
WIND SPEED:
AR-01 COMP SHINGLE- 1-Story 2X6 TRUSS 16'-1" 16" TOPSPEED,SEE DETAIL SNR-DC-30004 3 1'-5" 0'-10" 141 MPH 3-SEC GUST.
TOPSPEED S.S.LAG SCREW
D1-AR-0R-01-SCALE:1/8"=1'-0" (4)#14 X 2.25"SS SEALING
D A WASHER WOOD SCREWS FULLY
PITCH: 6° PENETRATING THROUGH WOOD
DECK
56'-1° ' ��p�,'lH OF R4ys,
2'-3"/—• 11'-7" • 15'-0" 29' •-}1'-6" INSTALLERS SHALL NOTIFY ENGINEER OF ANY o' ROLADE A. \
POTENTIAL STRUCTURAL ISSUES OBSERVED 3 ADL
� CIVIL �,
PRIOR TO PROCEEDING W/INSTALLATION. No. 57978
i q e sreorzo2a
2'9" MOUNT NUMBER FOR LEADING DOWNSLOPE �i�
` EDGE SHALL MATCH REQUIREMENTS LISTED
ABINS AL INSTALLATIONPERN TOPSPEEDTM 0 20°23
INSTALLATION MANUAL. STAMPED 02/20/2023
T1 -CONTRACTOR MAY SUBSTITUTE SNAPNRACK
DECKTRACK MOUNTS(SNR DETAIL
14'I 7" ` SNR-DC-00453)WITH A MAX OVERHANG OF 6• s u n r u n
J 9,r,
#180120
q o o --8-0-
-.1 �O,i !B5 MYLES STANDISH BLVD,TAUNTON,LIAR 02780,331
4- Foo
0
1
11'-T' 13-ll'J 23'-2" , 18'-11" / CUSTOMER RESIDENCE:
CHRISTINE BOULETTE
256 LONG POND DR,
38'-8" • YARMOUTH,MA,02664
TEL.(774)212-1713
APN:YARM-000059-000105
PROJECT NUMBER:
223R-256BOUL
DESIGNER: (415)580-6920 ex3
ENOCK KWIZERA
SHEET
LAYOUT
REV.A 2/20/2023
SEE SITE PLAN FOR NORTH ARROW PAGE
PV-3.0
Templete_verslo°40.67
0
120/240 VAC
SINGLE PHASE
SERVICE
METER#: NOTE:TOTAL PV BACKFEED=40A
K O EVERSOURCE 2389857 USED FOR INTERCONNECTION
UTILITY CALCULATIONS
GRID I
SUPPLY SIDE TAP
c
(I EXISTING 200A (N)LOCKABLE
BLADE TYPE (N)MA SMART
MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES:
1 DISCONNECT REVENUE SE7600H-USSN
METER 7600 WATT INVERTER /� JUNCTIONRO SOX T PV MODULES
i� A A `L J `1 J TRINA SOLAR:TSM-390DE09C.07
�\ EXISTING z /, (28)MODULES
200A MAIN • ,�,oe I O a—w� �— �_ ) *V., OPTIMIZERS WIRED IN:
FACILITY — PANEL (1)SERIES OF(14)OPTIMIZERS
40A FUSES I a I (1)SERIES OF(14)OPTIMIZERS
LOADS
SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT
D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440
120/240VAC CONNECTS TO TOP LUGS-
(UNE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
8e8 MYLES STANDISH BLVD,TAUNTON,MV,02 7 8 0.73 31
PHONED
FAX 0
CUSTOMER RESIDENCE:
CHRISTINE BOULETTE
256 LONG POND DR,
YARMOUTH,MA,02664
MODULE CHARACTERISTICS TEL. 774)212-1713
S440 OPTIMIZER CHARACTERISTICS: APN:(YARM o00059 000105
TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC
OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 223R-256BOUL
SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC
DESIGNER: (415)580-6920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1 ENOCK KWIZERA
SYSTEM SIZE: 10920 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 14 V
ELECTRICAL
SYSTEM OPERATING VOLTAGE: 400 V
MAX ALLOWABLE DC VOLTAGE: 480 V
SYSTEM OPERATING CURRENT: 27.3 A REV:A 2/20/2023
SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0
iempare_ve on J.0.87
AWA R N I N G INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE
ELECTRICAL SHOCK HAZARD fr PHOTOVOLTAIC DC DISCON - 110,21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
-"- " IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 'VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS,COLORS AND SYMBOLS.
TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
X PER CODE(S):NEC 2023:690.53,CEC 2022:690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2023:690.13(B),CEC
2022:690.13(B)
AWARNING
DUAL POWER SUPPLY
SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC
AND PV SOLAR ELECTRIC POWER SOURCE __—
SYSTEM
i LABEL LOCATION:
LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, CAUTION .
SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S):NEC 2023:705.12(C),CEC PER CODE(S):NEC 2023:890.31(D)(2),CEC 2022:
2022:705.12(C) 690.31(D)(2) ■
AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS FOR SOLAR PV SYSTEM / \ I�
OVERCURRENT DEVICE ) SOLAR PANELS ,��
ADJACENT TO ON: LABEL LOCATION: ON ROOF S u n run
ADJACENT TO PV BREAKER AND ESS INSTALLED WITHIN 3'OF RAPID SHUT DOWN J •
SWITCH PER CODE(S):NEC 2023:690.58(C)(2), --- - -
OCPD(IF APPLICABLE). CEC 2022:690.56(C)(2),IFC 2018:1204.5.3
PER CODE(S):NEC 2023:705.12(B)(3)2), I
CEC 2022:705.12(6)(3)(2) 4^ Y
A WARNING SOLAR PV SYSTEM EQUIPPED MAIN PANEL(INT) #180120
THIS EQUIPMENT FED BY 595 MYLES STANDISH DLVD,TAUNTON,MA.0ne0a001
MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN
/\ PHONEa
FAX
RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE:
SUPPLY OVERCURRENT DEVICE v." CHRISTINE ROULETTE
SHALL NOT EXCEED AMPACITY OF 256 LONG POND DR,
BUSBAR YARMOUTH,MA,02664
LABEL LOCATION: 3" TURN RAPID SHUTDOWN
PV LOAD CENTER(IF APPLICABLE)AND SWITCH TO THE"OFF" ry• •u SERVICE ENTRANCE TEL.(774)212-1713
ANY PANEL THAT UTIUZES"THE SUM I POSITION TO SHUT DOWN APN:YARM-000059-000105
OF BREAKERS RULE". PV SYSTEM AND REDUCE
FUSED AC DISCONNECT
PER CODE(S):NEC 2023:705.12 PROJECT NUMBER:
(B)(3)(3),CEC 2022:705,12(B)(3)(3) I SHOCK HAZARD IN THE INVERTER (EXT)— PV PRODUCTION 223R-256BOUL
ARRAY. MI I METER
PV SYSTEM DISCONNECT DESIGNER: (415)580-6920 ex3
MAXIM UMACOPFRATING CURRENT:32.00AMPS 256 LONG POND DR, YARMOUTH, MA, 02664 ENOCKKWIZERA
NOMINAL OPERATING AC VOLTAGE: 240 VAC -- SHEET
LABEL LOCATION:
PER CODE(S):NEC 2023:705.10,710.10,CEC 2022:705.10,710.10 SIGNAGE
LABEL LOCATION: ON ORR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
INTERCONNECTION. ARE CONNECTED. REV:A 2/20/2023
PER CODE(S):NEC 2023:690.54. PER CODE(S):NEC 2023:690.56(C),CEC 2022:690.56(C)
PAGE PV-5.0
Tamp•%vrdon_4.0.87