HomeMy WebLinkAboutBLDE-23-006072 Commonwealth of Official Use Only
Massachusetts
Permit No. BLDE-23-006072
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/4/2023
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 7 PAYSON PATH
Owner or Tenant FONTES DAVID E Telephone No.
Owner's Address FONTES STACEY L, 7 PAYSON PATH,WEST YARMOUTH, MA 02673
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(11 Panels 4.125 KW)(NO ESS)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alertine Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) e. .e ,
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe •
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
PP/ -9
I
Please email permit to eastmapermits@sunrun.com
gl, Commonwealth o�///a�eachu�el Official Use Only
* .� Permit No. 1��-3_G t 2 .
1 „_ , y 1= J leparlmenl o� ire Serviced
{ Occupancy and Fee Checked
i 1:. -: BOARD OF FIRE PREVENTION REGULATIONS j
!+ Q Rev. 1/07 (leave blank)
LI i z APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
LU 1 All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CM R 12.00
m L ASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 05/02/2023
co
City or Town of: Yarmouth To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)7 Payson Path
Owner or Tenant David Fontes Telephone No. (774)268-1112
Owner's Address 7 Payson Path Yarmouth MA 02673
Is this permit in conjunction with a building permit? Yes V No n (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service 100 Amps / Volts Overhead
E Undgrd® No.of Meters 1
New Service Amps / Volts Overhead n Undgrd n No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Installation of a interconnected, roof mounted, photovoltaic solar. 11 solar panels at 4.125 KwDC. NO ESS.
.•N„ Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units _
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Tonsl No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection
No.of Dryers Heating Appliances hN Security Systems:*
No.of Devices or Equivalent
No.of Water No.of No.of
KW
Heaters Data Wiring:
Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $5428 (When required by municipal policy.)
Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al
Licensee: Nathan Ashe Signature LIC.NO.:21136 A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519
Address: 695 Myles Standish Blvd. Taunton. MA 02780 Alt.Tel.No.:978 793-7881
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. I PERMIT FEE: $
Please email permit to eastmapermits@sunrun.com
•
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE IF DESCRIPTIONItin •SYSTEM SIZE:4125W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH
PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES:(11)VIKRAM SOLAR:VSMDHT.60.375.05 ED.CMR 780(2015 IRC/IBC/IEBC),MUNICIPAL CODE,AND ALL MANUFACTURERS'
• •INVERTERS:(1)SOLAREDGE LISTINGS AND INSTALLATION INSTRUCTIONS.
PV-2.0 SITE PLAN TECHNOLOGIES:SE3800H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023.
MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON
PV-3.0 LAYOUT COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. •
PV-4.0 ELECTRICAL
O. SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
IAC AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
O DC DISCONNECT(S)
•12.82 AMPS MODULE SHORT CIRCUIT CURRENT.
CB IQ COMBINER BOX •20.03 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)].
ABBREVIATIONS •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)
-1 INTERIOR EQUIPMENT (2).CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
A AMPERE
L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY• S U n i.U
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT
(E) EXISTING FLUSH ATTIC VENT VICINITY MAP685#180120
ESS ENERGY STORAGE SYSTEM PVC PIPE VENT a55TANDISHBLVD.TAUNfoN.NA,03TB0.]3)1
it, FAX 0
EXT EXTERIOR METAL PIPE VENT
k „...., .
CUSTOMER RESIDENCE:
INT \ INTERIOR DAVID FONTES
T-VENT
MSP MAIN SERVICE PANEL D 6 0 -,*,-' `� ;," ,','- ' 7 PAYSON PATH,YARMOUTH,
NI NEW SATELLITE DISH ry MA,02673
NTS NOT TO SCALE
ON CENTER TEL(774)268-1112
OC
- FIRE SETBACKS C APN:VARM-000086-000127
PREFAB PRE-FABRICATED
�, PROJECT NUMBER:
• PSF POUNDS PER SQUARE FOOT HARDSCAPE AI 223R-007FONT PV PHOTOVOLTAIC Bayberry Hllis
RSD RAPID SHUTDOWN DEVICE —PL- PROPERTY LINE GOIf Cows!, DESIGNER: (415)580-0920 eX3
--- SOLAR MODULES DAVID CLARK
TL TRANSFORMERLESS SCALE:NTS
7 Payson Path,West SHEET
TYPLAN TYPIC O., O Hills Yarmouth,MA 02673, REV NAME DATE COMMENTS COVER SHEET
V VOLTS ---
urse United States
W WATTS
REV:A 4/29/2023
LAN LANDSCAPE - _11 - O O
SNR MOUNT PAGE
POR PORTRAIT • SNR MOUNT&SKIRT PV-1.0
TemPate_w on 1.0.87
""E
C 1..."2( - C m 6 c'e7Z
•
SITE PLAN-SCALE=1/16"-1'
-------n
_ PL-� PL
�� P<
PL
tV
\CI
I11111
ll
Q
• Z
:4
_.-_._... (N)ARRAY AR-01
su n r u n
(E)RESIDENCE
swi AMP #180120
SE AC BBS MYLES STANDISH BLVD TAUNTON NA 02780.7.
PHONONED
FAX
1 CUSTOMER RESIDENCE:
11
PM INV DAVID FONTES
7 PAYSON PATH,YARMOUTH,
Ft
L______ PL MA,02673
PL TEL.(774)268-1112
PL �- •(N)ARRAY AR-02 APN:YARM-000086-000127
PROJECT NUMBER:
223R-007FONT
DESIGNER: (415)580-6920 ex3
DAVID CLARK
ARRAY TRUE MAG PV AREA SHEET
PITCH AZIM AZIM (SQFT) SITE PLAN
AR-01 30° 83° 97° 139.7
REV:A 4/29/2023
AR-02 30° 173° 187° 79.8
PAGE PV-2.O
Tsmp.n_a o,,4 0.87
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration
Span Spacing OC Spacing Overhang OC Spacing Overhang
AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-4" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 2'-0" STAGGERED 0°'`. OF MgSS,9
COMP,SEE DETAIL SNR-DC-00436 �4 cs
AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-4" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED Z HUMPHREY K (Pc,
SEE DETAIL SNR-DC-00436 f 1
KARIUKI
D1-AR-01-SCALE:3/16"=1'-0" �U SNO
AZJM:83' ii . ,
PITCH:30° 1.....__f-- 13'_4" ---.--_ ,• 11,_8„ y __.__._ __24' ---------k ;. ,�' TE
{ S/ONAL
I
3.-3" j
1
•
,o!-0„ Digitally signed
- - by Humphrey K
10'-6° �_ Kariuki
II
- -- - - = - Date:
•
•
I5" 2023.04.30
I 9"-.,' 04:00:25 -04'00'
D2 -SCALE:3/16"=1'-0" s u n r u n
A2JM:M:173173° —11'-2" 11'-8" 1'-3"
PITCH:30°
2'12"
e05 MYLES STANEASM BLVD.TAUNTON.MA.BPS0.73l1
ONES
6'-11"
CUSTOMER RESIDENCE:
DAVID FONTES
MIN 7 PAYSON PATH,YARMOUTH,
--------- MA,02673
TEL.(774)268-1112
APN:YARM-000086-000127
PROJECT NUMBER:
223R-007FONT
SEE SITE PLAN FOR NORTH ARROW
DESIGNER: (415)580-6920 ex3
DESIGN CRITERIA STRUCTURAL NOTES *IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY DAVID CLARK
ROOF PLANE EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE
MAX DISTRIBUTED LOAD:3 PSF
INSTALLERS SHALL NOTIFY ENGINEER OF ANY ADDED AND OVERHANG REDUCED WITHIN THE 12"BOUNDARY REGION ONLY SHEET
SNOW LOAD:30 PSF POTENTIAL STRUCTURAL ISSUES OBSERVED AS FOLLOWS: LAYOUT
WIND SPEED: PRIOR TO PROCEEDING W/INSTALLATION. **ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED
140 MPH 3-SEC GUST. BY 50%.
S.S.LAG SCREW REV:A 4/29/2023
5/16":2.5"MIN.EMBEDMENT **ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE
ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0
Tempate_verson_I 0 87
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
< O EVERSOURCE 2285359
UTILITY
GRID I NOTE:TOTAL PV BACKFEED=20A
-SUPPLY SIDE TAP USED FOR INTERCONNECTION
CALCULATIONS
(1 EXISTING 100A (N)LOCKABLEBLADE TYPE (N)MA SMART
MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES:
DISCONNECT REVENUE SE3800H-USMN
METER 3800 WATT INVERTER JUNCTION BOX PV MODULES
I;\ (� �4) OR EQUIVALENT COVIKRAM SOLAR:VSMDHT.60.375.05
EXISTING \�Jl _ / (11)MODULES
/ 125A MAIN
tiPANEL .----....,=,.. �_ O �— s _ �,i
,J '4// OPTIMIZERS WIRED IN:
\
FACILITY 20A FUSES I I (1)SERIES OF(11)OPTIMIZERS
LOADS ,1-aAoB�o SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT e
D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440
120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHWTHWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
605 MYLES STANCISH BLVO,TAUNTON,I.02760-7131
PHONED
F.0
CUSTOMER RESIDENCE:
DAVID FONTES
7 PAYSON PATH,YARMOUTH,
MA,02673
MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL.(774)268-1112
VIKRAM SOLAR:VSMOHT.60.375.05: 375 W MIN INPUT VOLTAGE B VDC APN:YARM-000086-000127
OPEN CIRCUIT VOLTAGE: 41.1 V MAX INPUT VOLTAGE 60 VDC PROJECT NUMBER:
MAX POWER VOLTAGE 34.9 V MAX INPUT ISC: 14.5 ADC 223R-007FONT
SHORT CIRCUIT CURRENT: 12.82 A MAX OUTPUT CURRENT: 15 ADC
DESIGNER: (415)580 6920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1 DAVID CLARK
SYSTEM SIZE: 4125 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE: 480 V
REV:A 4/29/2023
SYSTEM OPERATING CURRENT: 10.86 A
SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0
Tempate_w a 4O.67
/\WARNING* INVERTER I NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE
PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
ELECTRICAL SHOCK HAZARD_ IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSMON INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2023:600.7(D) INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S).AC/DC DISCONNECT(S). SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL OF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2023:690.13(B),
705.20(7),706.15(C)
Aw IN,
DUAL POWER SUPPLY
SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC
AND PV SOLAR ELECTRIC POWER SOURCE
l SYSTEM
LABEL LOCATION:
LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, CAUTION :SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S):NEC 2023:705.30(C) PER CODE(S):NEC 2023:690.31(D)(2)WARNING 1 RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS 7
OVERCURRENT DEVICE
i LABEL LOCATION:
LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN
ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(0)(2),IFC s u n r u n
OCPD(IF APPLICABLE). 2018 1204.5.3
PER CODE(S):NEC 2023:705.12(B)(2)
"& + ...-., Nr.4. SOLAR PV SYSTEM EQUIPPED .� #16012D
THIS EQUIPMENT FED BY % -- 695 MYLES STANDISH BLVD,TAUNTON.MA.MAW.
MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN NUMMI FAX 0
PHONE
RATING OF ALL OVERCURRENT ,
DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE:
SUPPLY OVERCURRENT DEVICE SOLAR PANELS ON ROOF DAVID FONTES
SHALL NOT EXCEED AMPACITY OF I _ 7 PAYSON PATH,YARMOUTH,
BUSBAR i3„ INVERTER MA,02673
LABEL LOCATION: TURN RAPID SHUTDOWN MAIN PANEL (INT)
PV LOAD CENTER OF APPUCABLE)AND SWITCH TO THE"OFF" SOLAR
AA.PAW.. (EXT) TEL.(774)268-1112
ANY PANEL THAT UTIUZES"THE SUM POSITION TO SHUT DOWN
SERVICE ENTRANCE API:YARN-000086-000127
OF BREAKERS RULE". PV SYSTEM AND REDUCE
PER CODE(S):NEC 2023:705.12(B)(3) SHOCK HAZARD IN THE —FUSED AC DISCONNECT PROJECT NUMBER:
ARRAY. MI
— PRODUCTION METER 223R-007FONT
DESIGNER: (415)580-6920 ex3
PV SYSTEM DISCONNECT
MAXIMUM AC OPERATING CURRENT:16.00 AMPS
7 PAYSON PATH, YARMOUTH, MA, 02673 DAVID CLARK
NOMINAL OPERATING AC VOLTAGE: 240 VAC LABEL LOCATION: - - - - SHEET
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) SIG NAG E
LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ARE CONNECTED.
REV:A 4/29/2023
INTERCONNECTION. PER CODE(S):NEC 2023:690.12(D) PAGE
PER CODE(S):NEC 2023:690.54
PV-5.0
Template ve n_40 e7