Loading...
HomeMy WebLinkAboutRevised plan with mitigation 2-28-24OUTSIDEFEMA ZONEFEMAZONE X (0.2%) RC FOUND IP FOUND EP1 14.50 1000 EP1 14.42 1001 EP1 14.39 1002 EP1 14.61 1003 EP1 14.69 1004 EP1 14.37 1005 EP1 13.74 1006 EP1 14.05 1007 14.2 EP1 14.47 1009 UP LAWN 14.60 1016 LAWN 14.70 1017 LAWN 14.66 1018 LAWN 14.56 1019 LAWN 14.41 1020 14.4 LAWN 14.21 1022 LAWN 14.16 1023 LAWN 14.18 1024 LAWN 14.26 1025 LAWN 14.30 1026 LAWN 14.33 1027 14.4 LAWN 14.46 1029 LAWN 14.55 1030 LAWN 14.58 1031 EG1 14.35 1032 14.4 14.3 EG1 14.10 1035 EG1 14.21 1036 EG1 14.28 1037 EG2 15.42 1038 EG2 14.53 1039 EG2 14.29 1040 EG2 14.11 1041 LAWN 14.29 1042 LAWN 14.36 1043 LAWN 14.29 1044 LAWN 14.53 1045 CL 6.8 STEPW1 14.37 1051 CL 6.8 STEPW1 15.27 1052THRESHOLD EL.=15.35 WALKS1 14.28 1054 14.4 14.5 WALKS1 14.55 1057 WALKS1 14.41 1058 WALKS1 14.37 1059 14.4 WALKS1 14.36 1061 14.1 WALKS2 14.59 1063 WALKS2 14.64 1064 WALKS2 14.65 1065 WALKS2 14.63 1066 CL 1.8FT WALKS2 14.61 1067 CL 1.8FT WALKS2 14.61 1068 CL 1.8FT WALKS2 14.61 1069CL 1.8FT WALKS2 14.63 1070 CL 1.8FT WALKS2 14.60 1071CL 1.8FT WALKS2 14.61 1072 CL 1.8FT WALKS2 14.57 1073 CL 1.8FT WALKS2 14.55 1074 CL 1.8FT WALKS2 14.56 1075 CL 1.8FT WALKS2 14.57 1076 CL 1.8FT WALKS2 14.63 1077 PADW1 14.94 1078 1079 14.98 PADW1 THRESHOLD EL.=15.31 1081 14.52 LAWN LAWN 14.35 1082LAWN 14.22 1083LAWN 14.24 1084LAWN 14.25 1085 CONC. COVER D=2.5 13.33 1086 CONC. COVER D=2.5 13.09 1087 BLD COR 21.51 1090 BLD COR 21.66 1091 ROOF OVER 21.84 1092 ROOF OVER 21.79 1093 RL RIDGE HT. 27.43 1094 ECLR4 11.41 1098 ECLR4 9.89 1099 ECLR4 11.68 1100 ECLR4 12.26 1101 LAWN 13.78 1103 LAWN 13.78 1104 DECK 14.65 1105 DECK 14.68 1106 BULKHEAD 13.86 1107 14.0 LAWN 13.15 1109 LAWN 13.93 1110 LAWN 14.80 1111 PATIOS1 14.58 1112 PATIOS1 14.60 1113PATIOS1 14.61 1114 PATIOS1 14.61 1115 PATIOS1 14.58 1116 PATIOS1 14.57 1117 ICV 14.48 1118 FENCE 13.05 1119 FENCE 13.96 1120 FENCE 17.33 1121 BLD COR 20.54 1124 BLD COR 20.84 1125 BLD COR 21.87 1126 BVW-2 BVW-3 BVW-4 BVW-5 xxxxxx xx xx xxC O A S T A L B A N KF E M A Z O N E A E ( E L . 1 1 ' )FZFZFZFZFZFZFZFZFZFZ FZ FZFZFZFZFZFZ FZ F Z FZF Z FZ FZ FZFZFZOHWOHWOHWOHWOHWOHWOHWOHWOHWOHWOHW OHW OHW OHW OHW OHW OHW FZ FZ F Z F Z F Z F Z FZFZFZFZFZFZ46810121414 1210 8 6 4 FEMA ZONE XX (0 .2%) C B C B CBCBCBCBCBCB5 0 ' B U F F E R 5 0 ' BUFFER50' BUFFER50' BUFFER50' BUFFER50' BUFFER50' BUFFER50' BUFFER100' BUFFER100' BUFFER100' BUFFER100' BUFFER100' BUFFER100' BUFFER100' BUFFER100' BUFFER50' 50' PARCEL ID 20-80 (ON TOWN WATER) PARCEL ID 20-83 (ON TOWN WATER) PARCEL ID 28-58.1.1 #26 DWELLING FIN. FL. EL. = 15.3 L A W N L A W N M U L C H M U L C H STONE STEPPER (TYP)DECKWOOD STOOP P L A N T SP L A N T S AC ELEC. METER BULKHEAD P L A N T S WOOD STOOP GLENWOOD STREET(40' WIDE - PUBLIC)EDGE OF PAVEMENTEDGE OF PAVEMENT14EDGE OF LAWNPAVER PATIO STOCKADE FENCE STOCKADE FENCE N 47° 50' 33" W97.59' S 47° 50' 33" E 93.15'S 42° 09' 27" W75.00'N 46° 18' 35" E25.07'N 45° 09' 25" E50.07'GAS METER 9.2'27.9'38.0'28.7' 34.5' G G G G G G G W W W W W WSS SS S S 10.0'10.0' 20.5' 10.6' PROPOSED LEACH FIELD PROPOSED 1,500 GALLON SEPTIC TANK PROPOSED 3 BEDROOM DWELLING F.F.= 15.5 PROPOSED D-BOX RINSE STATION PROPOSED DECK PROPOSED BULKHEAD LIMIT OF FULL BASEMENTWATERLINE TO BE RELOCATED OR SLEEVED WITHIN 10' OF SEPTIC SYSTEM APPROX. LOCATION OF EXISTING LEACH PITS (PER OWNER)10.0'10.0' RESERVE AREALIMIT OF SLABTP1 TP2 TP3 TP4 APPROXIMATE LOCATION OF GAS LINE TO BE RELOCATED AS REQUIRED 30.5' 38.1' (PROPOSED DECK TO CB) 73.9' (PRO P O S E D D E C K T O B V W ) 47.7' (EXISTING H O U S E T O C B ) 85.6' (E X I S T I N G H O U S E T O B V W ) 84.1' (PROPOS E D H O U S E T O B V W ) 50.0' (PROPOSED HOUSE TO CB) 20 . 5 ' ADDITIONAL DRIVEWAY AREA TO CONNECT GARAGE ENTRANCE TO EXISTING GRAVEL DRIVE EXISTING GRAVEL DRIVEWAY EXISTING STONE STEP WALK TO BE RELOCATED WWWWWWEDGE OF LAWN G G G G G PARCEL ID 20-82.1 7,140 S.F. 128.1' S.A . S . T O B V W BENCHMARK TOP ROD AND CAP ELEVATION = 15.10' NAVD88APPROX BVW / VEGETATEDWETLAND LIMITSPROPOSED SEDIMENTATION CONTORLS PROPOSED SEDIMENTATION CONTORLS F E M A Z O N E X ( 0 . 2 % ) 18" POSTS ALONG PROPERTY LINE SPACED AT 10' TO DEMARCATE PROPERTY LINE PROPOSED ROOF DRYWELL ANDDDD D D D D D LANDSCAPE CUTTINGS AND DEBRIS TO BE REMOVED AREA TO BE ALLOWED TO REVEGETATE NATURALLY OVER TIME 846 S.F. MITIGATION 5' WIDE FOUNDATION PLANTING 166 S.F. MITIGATION 5' WIDE FOUNDATION PLANTING 182 S.F. MITIGATION DD D D 2' WIDE DRIP STRIP WITH UNDERDRAIN, TIE TO DRYWELL NOT TO SCALELOCUS MAP N N NAD 8310 SCALE: 1" = 10' 0 20 30 40 SEPTIC SYSTEM NOTES 1.ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.00), AND THE LOCAL BOARD OF HEALTH. 2.THERE SHALL BE NO CHANGES MADE IN THIS PLAN WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER AND LOCAL BOARD OF HEALTH. 3.ALL ERRORS, OMISSIONS, AND CHANGE OF CONDITIONS AT THE SITE SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PERFORMING THE RELATED WORK. 4.ALL DISTURBED AREAS ARE TO BE LOAMED, SEEDED AND MAINTAINED TO PREVENT EROSION. 5.FOR PROPER PERFORMANCE, SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND WHEN THE TOTAL DEPTH OF SCUM AND SOLIDS EXCEEDS 1/3 THE LIQUID DEPTH OF THE TANK, THE TANK SHOULD BE PUMPED. 6.THIS SYSTEM HAS BEEN DESIGNED FROM DATA REVIEWED AND ACKNOWLEDGED BY THE MASS. D.E.P. AND THE LOCAL BOARD OF HEALTH; AND CONFORMS WITH THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE 5. NO GUARANTEE OF PERFORMANCE IS EXPRESSED OR IMPLIED. 7.TEST HOLE INFORMATION SHOWN HEREON IS LIMITED TO SOIL CONDITIONS FOUND AT THAT PARTICULAR TEST HOLE LOCATIONS AND IS NOT CONSIDERED AN IMPLIED OR EXPRESSED WARRANTY OF SOIL CONDITIONS BEYOND LIMITS OF SUCH TEST HOLES. 8.ALL ORGANIC AND UNSUITABLE MATERIAL MUST BE REMOVED FROM THE AREA DIRECTLY UNDER AND 5 FEET BEYOND THE PROPOSED LEACHING FACILITY. THIS AREA MUST BE BACKFILLED TO THE ELEVATIONS INDICATED ON THESE PLANS WITH SELECT ON-SITE OR IMPORTED SOIL MATERIAL, CONSISTING OF CLEAN GRANULAR SAND OR OTHER GRANULAR MATERIAL, FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS SHALL NOT BE USED. THE FILL MATERIAL SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 - 310 CMR SECTION 15.255 (3) AND SHALL HAVE PERCOLATION RATE OF BETWEEN TWO AND FIVE MINUTES PER INCH, BEFORE AND AFTER PLACEMENT. 9.ALL STONE MUST BE DOUBLE WASHED AND FREE FROM FINES AND ANY ORGANIC MATERIAL AND MUST HAVE LESS THAN 0.2 PERCENT MATERIAL FINER THAN A NUMBER 200 SIEVE. 10.THE DESIGNER HAS NOT BEEN RETAINED BY THE CLIENT TO CONSTRUCT OR SUPERVISE THE CONSTRUCTION OF THE SYSTEM. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ARRANGEMENTS FOR INSPECTION OF INSTALLATION OF THE SYSTEM WITH THE LOCAL BOARD OF HEALTH. 11.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL OF ALL SYSTEM COMPONENTS. 12.TIGHT JOINT PIPING MATERIAL TO CONSIST OF POLYVINYL CHLORIDE (P.V.C.) SCHEDULE 40, UNLESS OTHERWISE NOTED. 13.THE CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER FOR CONSTRUCTION INSPECTION AFTER EXCAVATION FOR THE LEACHING BED (PRIOR TO THE PLACEMENT OF STONE) AND ALSO AFTER PLACEMENT OF PIPE & STONE PRIOR TO BACKFILLING. 14.DESIGN ENGINEER SHALL CERTIFY CONSTRUCTION OF SYSTEM AND MATERIALS INSTALLED. THE CONTRACTOR SHALL PROVIDE A SIEVE ANALYSIS OF THE FILL MATERIAL REQUIRED. AN AS-BUILT PLAN SHALL BE SUBMITTED TO THE LOCAL BOARD OF HEALTH UPON COMPLETION. 15.NO RUBBER TIRE CONSTRUCTION MACHINERY SHALL DRIVE OVER THE PROPOSED SEPTIC BED EXCAVATION DURING CONSTRUCTION. 16.DIG-SAFE AND ALL OTHER NECESSARY AUTHORITIES SHALL BE NOTIFIED FOR THE PROPER LOCATION OF EXISTING UTILITIES PRIOR TO ANY EXCAVATION. 17.WATER SERVICE LINE SHALL BE LOCATED AND MARKED PRIOR TO ANY EXCAVATING AND 10' MIN. SETBACK DISTANCE FROM SAID SERVICE TO THE SEPTIC SYSTEM SHALL BE MAINTAINED. 18.ALL WATER LINES WITHIN 10' OF SEPTIC SYSTEM COMPONENTS SHALL BE SLEEVED WITHIN 4" PVC SCHEDULE 40 PIPE. LOCUS SOIL EVALUATOR'S LOG PERCOLATION RATE = < 2 MINUTES / INCH IN C1 LAYERS DEPTH TO GROUNDWATER = NONE ENCOUNTERED PERC TEST PERFORMED #3 - DEPTH 36" - 54" 24 GALLONS IN 6:00 ADJUSTED HIGH GROUNDWATER = ESTIMATED AT ELEVATION 45 FEET (NAVD88) OBSERVATIONS BY: GLEN HARRINGTON, R.S.. WITNESSED BY: BARRY LEWIS DATE TESTED: AUGUST 31, 2023 Depth from surface in inches Soil Horizon Soil Texture (USDA) Soil Color (Munsel) Soil Mottles and Depth Other Relative Factors DEEP OBSERVATION HOLE TP#1 AND TP#2, ELEVATION 14.4 0 - 3"A LOAMY SAND 10YR 4/1 3" - 48"Bw LOAMY SAND 10 YR 5/6 48" - 126"C1 M/C SAND 2.5 Y 6/4 10% GRAVEL NO GW DEEP OBSERVATION HOLE TP#3 AND TP#4, ELEVATION 14.5 0 - 4"A SANDY LOAM 10 YR /1 4" - 47"B SANDY LOAM 5 YR 6/4 47" - 120"C1 M/C SAND 2.5 Y 6/4 10% GRAVEL NO GW DESIGN DATA 1.TYPE OF ESTABLISHMENT: 3-BEDROOM SINGLE FAMILY RESIDENCE 2.SEWAGE SYSTEM DESIGN FLOW: 110 GALLONS PER BEDROOM = 110 x 3 = 330 GPD 3.NOTE: THIS SEPTIC SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER 4.SEPTIC TANK CAPACITY REQUIRED, MINIMUM OF 200% OF DESIGN FLOW OR 1,500 GAL. = 200% x 330 GALLON = 660 GALLON (USE 1,500 GALLON TANK) 5.DESIGN PERCOLATION RATE: ASSIGNED LESS THAN 5 MINUTES PER INCH 6.SOIL ABSORPTION SYSTEM TYPE: CHAMBER SYSTEM 7.LEACHING AREA REQUIRED: MINIMUM 330 GPD / (0.74 GPD/S.F., CLASS I SOIL) = 445 S.F. 8.LEACHING SYSTEM PROPOSED: 29.00' LONG x 10.83' WIDE x 2' HIGH SYSTEM BOTTOM AREA PROPOSED = 10.83' x 29.00' = 314 S.F. SIDE AREA PROPOSED = 2 x (10.83' + 29.00') x 2' = 159 S.F. TOTAL AREA PROPOSED = 314 S.F. + 159 S.F. = 473 S.F. 9.LEACHING SYSTEM CAPACITY PROPOSED = 473 S.F. x 0.74 GPD/S.F. = 350 GPD 11 9 8 10 12 76 5 13 414 16 3 2 1 S=0.02 L=16' S=0.01 L=17'S=0.02 L=VARIES PRECAST 500-GALLON CHAMBERS USE (2) 500-GALLON CHAMBERS WITH DOUBLE WASHED CRUSHED STONE 48" AT ENDS AND BETWEEN, 36" AT SIDES EFFECTIVE DIMENSIONS: HEIGHT = 2.0', LENGTH = 29.0', WIDTH = 10.83'4.50'4.75'34"OVERALLHEIGHTH-20 D-BOX WITH SPEED LEVELERS 24"EFFECTIVESIDEWALLBACK FILL WITH 9" MIN. 36" MAX. CLEAN MATERIAL PROPOSED 4" PVC OUTLET "T" AND SEWER PIPE. CONTRACTOR SHALL CONFIRM EXISTING INVERT ELEVATION PRIOR TO INSTALLATION OF SYSTEM CONTRACTOR SHALL CONTACT ENGINEER TO ASSESS EXISTING SOIL MATERIAL PRIOR TO INSTALLATION OF LEACHING SYSTEM. UNSUITABLE MATERIAL ENCOUNTERED DURING INSTALLATION SHALL BE REMOVED - REFER TO SEPTIC SYSTEM NOTE 9 PROPOSED SEPTIC TANK 1,500 GALLON, H-20 LOADING 6" MIN. COMPACTED CRUSHED STONE BASE FILTER FABRICS=2% MINIMUM GAS BAFFLE SCH. 40 PVC TEES10"14"H-20 RISER AND COVER TO BE SET TO WITHIN 6" OF FINISHED GRADE COVER TO SERVE AS INSPECTION PORT SEWAGE SYSTEM PROFILE & DETAILS NOT TO SCALE NOTES: 1.FURNISH RISERS TO SET COVERS WITHIN 6 INCHES OF FINISH GRADE. 2.H-20 SEPTIC TANK, CHAMBERS AND H-20 DISTRIBUTION BOX (D-BOX), AND SCHEDULE 40 PVC PIPE THROUGHOUT. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A TRENCH PERMIT FROM THE LOCAL MUNICIPALITY IN WHICH THE WORK IS BEING PERFORMED. PREPARED FOR: PREPARED BY: DRAWING TITLE: PROJECT: ASSESSORS INFORMATION: SUMMERFIELD PARK 800 FALMOUTH ROAD SUITE 301C MASHPEE, MA 02649 508.477.7272 PHONE 508.477.9072 FAX www.CapeEng.com SHEET NO.: OF DATE: DRAWN BY:CHECKED BY: 1 1 WEST YARMOUTH, MASSACHUSETTS BRIDGEWATER, MA 02324 1121 VERNON STREET ERIK MOORE MD MC DECEMBER 12, 2023 (INCREASE IN FLOW) MAP 20 PARCEL 82.1 DESCRIPTIONDATE CHKBY 2/16/24 ADD DRYWELLS, MITIGATION AND PL DEMARKATION MD NOTICE THIS PLAN MAY NOT BE ADDED TO, DELETED FROM, OR ALTERED IN ANY WAY BY ANYONE OTHER THAN CAPE & ISLANDS ENGINEERING, INC. UNLESS AND UNTIL SUCH TIME AS AN ORIGINAL (RED) STAMP APPEARS ON THIS PLAN NO PERSON OR PERSONS, MUNICIPAL OR PUBLIC OFFICIAL MAY RELY UPON THE INFORMATION CONTAINED HEREIN; AND THIS PLAN REMAINS THE PROPERTY OF CAPE AND ISLANDS ENGINEERING, INC. COPYRIGHT (C) BY CAPE & ISLANDS ENGINEERING, INC. ALL RIGHTS RESERVED 26 GLENWOOD STREET GENERAL NOTES LOCATIONS ARE BASED ON AN "ON THE GROUND" INSTRUMENT SURVEY AND ELEVATIONS BASED ON THE NAVD 1988 DATUM. COORDINATE SYSTEM USED IS THE MA-MAINLAND COORDINATE SYSTEM, DATUM: NAD 83, UNITS: U.S. SURVEY FEET. THE FINISHED FLOOR ELEVATION (FIN. FL. EL.) SHOWN HEREON IS BASED ON AN ASSUMED 1" LOWER THAN THE SURVEYED THRESHOLD ELEVATION. AN INTERIOR INSPECTION OF BUILDINGS WAS NOT PERFORMED. ZONING DISTRICT: R25 PROPERTY IS LOCATED WITHIN AN AREA HAVING A ZONE DESIGNATION OF ANNUAL CHANCE FLOOD ZONE 0.2% AND MINIMAL FLOOD HAZARD ZONE X BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), ON FLOOD INSURANCE RATE MAP NO. 25001C0569J, WITH A MAP EFFECTIVE DATE OF JULY 16, 2014. THIS LOT IS NOT WITHIN THE WINDBORNE DEBRIS REGION (ONE MILE FROM SHORELINE) AS SHOWN ON THE FALMOUTH HIGH WIND DISTRICT MAP. THIS LOT IS NOT LOCATED WITHIN A DEP APPROVED ZONE II WELLHEAD PROTECTION AREA. THE LIMITS OF BORDERING VEGETATED WETLANDS / VEGETATED WETLANDS WERE SURVEYED IN THE FIELD BY CAPE & ISLANDS ENGINEERING AND ARE SHOWN ON THE ATTACHED PLAN AS THE APPROXIMATE WETLAND LIMITS. THIS LOT IS NOT MAPPED WITHIN A MESA NATURAL HERITAGE AND ENDANGERED SPECIES AREA. WIND EXPOSURE CATEGORY: ZONE C LOT COVERAGE: LOT AREA = 7,140 S.F EXISTING LOT COVERAGE BY STRUCTURES (HOUSE AND DECKS)= 801 S.F. (11.2%) PROPOSED LOT COVERAGE BY STRUCTURES (HOUSE AND DECKS):= 1,392 S.F. (19.5%) DEED REFERENCE: BOOK 35707 PAGE 255 PLAN REFERENCE:BOOK 26 PAGE 103 OWNER: ERIK H. AND REBECCA C. MOORE 1121 VERNON STREET BRIDGEWATER, MA 02324 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL DWELLING FIRST 2' SHALL BE SET LEVEL H-20 RISER AND COVER TO BE SET TO WITHIN 6" OF FINISHED GRADE COVER TO SERVE AS INSPECTION PORT BOTTOM OF TEST HOLE SCHEDULE OF ELEVATIONS 1 FIRST FLOOR =15.5 2 TOP OF FOUNDATION =14.5 +/- 3 PIPE INV. AT FOUNDATION =12.00 4 INV. OF PIPE AT SEPTIC TANK INLET =11.68 5 INV. OF PIPE AT SEPTIC TANK OUTLET =11.43 6 INV. OF PIPE AT D-BOX INLET =11.09 7 INV. OF PIPE AT D-BOX OUTLET =10.92 8 INV. OF PIPE AT LEACHING FIELD INLET =10.75 9 BOTTOM OF LEACHING FIELD =8.75 10 TOP OF STONE 11.58 11 FINISHED GRADE OVER LEACHING FACILITY =14.4 - 14.3 12 FINISHED GRADE OVER D-BOX =14.4 13 FINISHED GRADE OVER SEPTIC TANK =14.4 14 FINISHED GRADE AT FOUNDATION =14.4 SITE AND SEPTIC PLAN OHW HYDRANT WATER SHUTOFF CATCH BASIN SQUARE UTILITY POLE GUY POLE GUY WIRE LIGHT POLE SIGN CONIFEROUS TREE DECIDUOUS TREE TREE LINE OVERHEAD WIRES STONE WALL POST & RAIL FENCE STOCKADE FENCE x x x PICKET ROW xx xx CHAIN LINK FENCE LEGEND IRON PIPE FOUND CONCRETE BOUND IP CB TREE STUMP STONE BOUNDSB RC ROD CAP SHRUB CONIFEROUS SHRUB AREA OF STRUCTURE INCLUDED IN EXISTING LOT COVERAGE CONSERVATION NOTES PRIOR TO ANY WORK COMMENCING, THE DEP FILE NUMBER SHALL BE POSTED ON A SIGN ON THE STREET SIDE OF THE LOT AND MAINTAINED IN A VISIBLE CONDITION THROUGHOUT THE PROJECT. THE LIMIT OF WORK WILL BE INSTALLED PRIOR TO ANY WORK, EXCAVATION, CONSTRUCTION OR CLEARING OF VEGETATION, IN ORDER TO PREVENT DAMAGE TO THE INTERESTS OF THE ACT AND BYLAW. THE LIMIT OF WORK WILL CONSIST OF A ROW OF STAKED SEDIMENT STOP OR COMPOST ROLL WITH SILTATION FENCE BACKING. THE SEDIMENT STOP ROLL WILL BE REPLACED AS NECESSARY TO BE MAINTAINED IN GOOD CONDITION THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. NO FILL WILL BE ALLOWED TO BE PLACED AGAINST THE LIMIT OF WORK AT ANY TIME. UPON COMPLETION OF ALL CONSTRUCTION AND STABILIZATION OF THE SITE, SEDIMENT STOP ROLL WILL BE REMOVED AND PROPERLY DISPOSED OF. PRIOR TO ANY WORK COMMENCING, ADVANCE WRITTEN NOTIFICATION WILL BE PROVIDED TO THE LOCAL CONSERVATION COMMISSION. NO DEBRIS, EQUIPMENT OR MATERIALS WILL BE STORED, EVEN TEMPORARILY, OUTSIDE THE DESIGNATED LIMIT OF WORK AREA WITH THE EXCEPTION OF EQUIPMENT AND MATERIALS RELATED TO THE PLANTINGS FOR THE REQUIRED MITIGATION. THE CONSTRUCTION SITE WILL BE CLEANED DAILY TO REMOVE ANY LOOSE DEBRIS. ALL DISTURBED AREAS WITHIN THE LIMIT OF WORK REQUIRING RESTORATION WILL STABILIZED TO PREVENT EROSION. STABILIZATION WILL BE DONE IMMEDIATELY FOLLOWING COMPLETION OF CONSTRUCTION. WORK AREA LIES COMPLETELY WITHIN PREVIOUSLY DISTURBED BUFFER ZONE AREAS. IF APPLICABLE, FERTILIZER APPLICATION AND LAWN MAINTENANCE TO BE PERFORMED IN ACCORDANCE WITH LOCAL REGULATION NITROGEN LOADING/LAWN STANDARDS. MITIGATION PLANTING NOTES PROPOSED MITIGATION PLANTINGS TO BE 2 GALLON CONTAINERS OR LARGER, STAGGERED IN FORMATION AND PLANTED 3 FEET ON CENTER OR AS NECESSARY TO ADEQUATELY RE-VEGETATE AREA. PROPOSED PLANTINGS INCLUDE: BAYBERRY (Myrica pensylvanica) AND/OR INKBERRY (Ilex glabra compacta) - 25% OF MITIGATION AREA. ARROWWOOD (Viburnum dentatum), BLACK CHOKEBERRY (Aronia melanocarpa), AND/OR MAPLELEAF VIBURNUM (Viburnum acerfolium) - 25% OF MITIGATION AREA. BLACK HUCKLEBERRY (Gaylussacia baccatta), CAROLINA ROSE (Rosa Carolina) AND/OR SWEET PEPPERBUSH (Clethra alnifolia) - 50% OF MITIGATION AREA THE APPLICANT OR APPLICANT'S REPRESENTATIVE SHALL HAVE AN ONSITE MEETING WITH CONSERVATION AGENT PRIOR TO INSTALLING PLANTS TO REVIEW LOCATION OF SPECIFIC PLANT SPECIES. ANY CHANGES IN PLANT SPECIES SHALL BE APPROVED BY CONSERVATION AGENT PRIOR TO INSTALLATION. AFTER PLANTING, THE MITIGATION AREAS SHALL BE SEEDED BY HAND WITH NEW ENGLAND WETLAND PLANTS NATIVE WARM SEASON GRASS MIX FOR EROSION CONTROL IN ACCORDANCE WITH THE MANUFACTURE'S DIRECTIONS. THE MIX SHALL BE APPROVED BY THE CONSERVATION AGENT PRIOR TO BROADCASTING. PLANTINGS SHALL BE MAINTAINED IN GOOD HEALTH. PLANTINGS SHALL BE INSTALLED PRIOR TO CONSTRUCTION COMPLETION . OWNER SHALL NOTIFY CONSERVATION AGENT FOR FINAL INSPECTION WITHIN 30 DAYS AFTER PLANTINGS HAVE BEEN INSTALLED. MITIGATION PLANTING NOTES EXISTING DEVELOPMENT IN THE 35-50 FT BUFFER 23 S.F. PROPOSED DEVELOPMENT IN THE 35-50 FT BUFFER 218 S.F. NET INCREASE 35-50 BUFFER 195 S.F. MITIGATION REQUIRED 3:1 585 S.F. EXISTING DEVELOPMENT IN THE 50 - 100 FT BUFFER 932 S.F. PROPOSED DEVELOPMENT IN THE 50 - 100 FT BUFFER 1,237 S.F. NET INCREASE 50 - 100 FT BUFFER +305 S.F. MITIGATION REQUIRED 2:1 610 S.F. TOTAL MITIGATION REQUIRED 1,195 S.F. TOTAL MITIGATION PROPOSED 1,195 S.F. RNDS PRO FLOW-WELL PLAN VIEW 2'6'2'4" PVC INLET 3/4"-1-1/2" DOUBLE WASHED STONE ROOF LEADER OVERFLOW PIPE FINISH GRADE, VARIES SPLASH PLATE 8" MIN. LOAM COVER PIPE, S= 1.0% 4" HDPE DRAIN 2'2' INLET SECTION VIEW DRY WELL DETAIL -NOT TO SCALE- NOTES: A SYSTEM OF GUTTERS, DOWNSPOUTS AND DRY WELLS SHALL BE USED TO RECHARGE STORMWATER RUNOFF. PICTURES OF DRY WELL SHOULD BE TAKEN DURING INSTALLATION AND SUPPLIED TO CONSERVATION COMMISSION AS PART OF THE CERTIFICATE OF COMPLIANCE REQUEST. 6" MINIMUM BEDDING STONE