HomeMy WebLinkAboutEngineer Plans - 2024SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT TOP FOUND. EL 27.2' ACCESS COVER AT FIN. GRADE ACCESS COVER TO WITHIN 6" OF FIN. GRADE MINIMUM 1' OF COVER MINIMUM .75' OF COVER ' OVER POLY TANK OVER PRECAST 1 4"DSCH40 PVC 427.3' .• 16.1 " 1.34' ( ) PIPES LEVEL 1ST 2' **EXISTING 1,500 23.87' GALLON POLYETHYLENE SEPTIC TANK GAS (H-10) BAFFLE o°o°o°o°o°o WATERTEST D'BOX 23.57', .-' °Oo�ono°o'o° FOR LEVELNESS 23.77' 23.6' 6" CRUSHED STONE 021MEC]}ANICALL/ r.: • COMPACTION. ( NOTE: 2 MIN. WALL DEPTH OF FLOW = 4' THICKNESS REQUIRED REQUIRED TEE SIZES: INLET DEPTH = 10 MIN. BELOW FLOW LINE OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE NOTE: STANDARD TEES ARE TO BE USED. DO NOT USE MANUFACTURER'S TEES THAT COME WITH THE TANK (_t_% SLOPE) (1 % SLOPE) FOUNDATION EXIST. SEPTIC TANK 10' D' BOX 5' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS SEPTIC TANK SIZE AT 1500 GALLONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE I (� N I F) CONDITIONS IF NOT SUITABLE 99 - EXISTING CONTOUR X 99. 1 EXIST. SPOT ELEV. -[991--- PROPOSED CONTOUR 198•4] PROPOSED SPOT EL. TH1 TEST HOLE 21. SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 11 /21 / 18 PERC. RATE _ < 2 MIN/INCH CLASS i SOILS 4 ELEV. 0" 1 27.3' A LS 12" 1OYR 3/6 B LS 30" 1 OYR 5/6 24 8' PERC C FS 1OYR 7/4 126" 116.8' NO GROUNDWATER ENCOUNTERED DCE #24-028 a BENCHMARK: CORNER BULKHEAD = 27.1' NAVD88 MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW INSPECTION PORT GRADE 2% SLOPE FILTER FABRIC TOP 23.9' IC26.9 / FINISHED GRADE- 4" LOAM &SEED CLEAN FILL 4" PERFORATED PVC 3' O.C. S=0.005 0 0 3/4"-1-1/2." DOUBLE WASHED 0 8" STONE LEACHING FIELD 0 LEVEL BOTTOM 0 30.0, LEACHING FACILITY 22.9' 6.1' NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. --- 4. DESIGN LOADING FOR ALL PROPOSED UNITS TO BE AASHTO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 6. 6. MIN. MI WITH 310 CMR 15.000 (TITLE 5.) -BELOW I 22,4' 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 16.8' BOTTOM TH-1 10. CONTRACTOR SHALL BE RESPONSIBLE FOR NO GROUNDWATER FOUND CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1 "=2000'f WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 106 PARCEL 40 BE REMOVED BENEATH AND 5' AROUND THE (ARIANCE REQUESTED: PROPOSED LEACHING FACILITY, LOCUS IS WITHIN FEMA FLOOD ZONE X 1NDER MAX. FEASIBLE COMPLIANCE 15.405: 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (AREA OF MINIMAL FLOOD HAZARD) AS 1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 13.5') AND CONTAMINATED SOIL 5' AROUND AND BENEATH SHOWN ON COMMUNITY PANEL #25001CO578J THE EXISTING LEACHING FIELD SHALL BE REMOVED. DATED 7/16/2014 PROVID 6' DF 0 MIL LINER AT 5' ,Q6 SAS IN EA SREELIN - SHOWN. T AT ELFO . 23.9',12•60 BOTTOM A EL 19.9 201 2 OOD P��E a CO C. �2 ����� DRI E 0 PATIO Scale: 1 • • 20 30 40 50 VIZE a i EXISTING DWELLING TOF=27.2 ,w , ROAD TIE LOT SIZE \ X 11,731 SFf 15.1g ..a 0 w `o w N N REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3). SYSTEM DESIGN; GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1500 GAL. SEPTIC TANK LEACHING; 330 GPD (.74) = 446 SF REQUIRED 15'X30'=450SFOK 450 SF X .74 = 333 GPD OK 2ND FLOOR USE A 15' X 30' PIPE AND STONE LEACHING FIELD C� MA APPROVED DATE BOARD OF HEALTH DINING ROOM Yarmouth thDepartment DO !� BED RBATHOOM KITCHEN AfNFAG ®i�`ED ROOM -n%v GARAGE ..,,le Date LIVING IL OOM DINING R ROOM 1 ST FLOOR TITLE 5 SITE PLAN OF `irm SN OF r'o DANIEL �GswJ DANIELA. ctiGs oA. OJA � OJALA pc; 0 CIVIL s No.409800 No.46502 ✓�, �� �IE� �S.�NgL Ea, �.`Ya BED ROOM FLOOR PLAN NOT TO SCALE OF hf1j'- R.q� -: Ceti, ` �� t)F MA,S\ v Rio I CJALA rro` DiANIEL CIVIL A. 'd IN,- 46502 `� OJALA 0. 40,980 o� S J R`� 7 DATE DANIEL A. OJALA, P.E., P.L.S. #85 FREEMAN ROAD YARMOUTH PORT, MA PREPARED FOR CC CONSTRUCTION DATE: FEBRUARY 12, 2024 off 508-362-4541 fax 508-362-9880 downcape.com eeel-ill g ke. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 24-028 CC CONSTRUCTION