Loading...
24-A020 16 Church StreetRELIEVED TOWN OF YARMOUTH FEB 2�24 1146 ROUTE 28, SOUTH YARMOUTH. MA 02664-4451 Telephone (508) 3W2231 Ext. 1292—Fax (508) 398-0836 of x Ohl iu'OLD _ING'S HIGHWAY HISTORIC DISTRICT COMMITTEE APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application PLEASE SUBMIT 4 COPIGS OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL. INFORMATION. Check All Categories That Apply: Indicate type of Building: _... Commercial X Residential 1) Exterior Building Construction: New Building Addition _Alterations Reroof Garage Shed Solar Panels X Other: 2) Exterior Painting' Siding Shutters Doors Trim Other: 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole Pool Other: Please type or print legibly: Address of proposed work, 16 Church St, Yarmouth Port, MA 02675 _ MaplLot # 7 Owner(s): Peter Barnes Phone A (248) 310-0213 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 16 Church St, Yarmouth Port, MA 02675 Year built: 1940 Email: peter@brayfarmllc.com Agenticontractor Tristan Souza of Venture Home Solar Preferred notification method: Phone X Email Mailing Address: 231 Weaver St Unit E Fall River, MA 02720 Phone #: 508-808-3704 Email permittingma@venturesolar.com Preferred notification method: Description of Proposed Work: qo -,%IN pWVcls av) 51 a=0- 2Mn rYir.I�Yao s Signed (Owner or agent) 7� Phone X Email Date: 2/2/2024 Ownerlconlractorlagent is aware that a permit is required from the Building Department (Check other departments, also.) > If application is approved, approval Is subject to a 1U-day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later ➢ All new construction will be subject to Inspection by OKH OKH-approved plans MUST be available on -site for framing 8 final inspections Rcvd Date: �"► Amount 11-- CasIVCK #: fD Rcvd by: 4�)� 45 Days: Date Signed: Approved Approved with Modifications Denied Reason for Denial. Signed. '- Aoa0 APPLICATION #: TOWN OF YARMOUTH 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398-2231 Ext. 1292 Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 45-DAY TIMEFRAME WAIVER Application #: q, Av;�a Project Address: 16 Church St, Yarmouth Port, MA 02675 Application Received Date: 45 Day Decision Deadline: 2✓'! �,_ Me, the undersigned owner, contractor, or agent, do hereby waive the 45-day timeframe for a determination on our application for a Certificate of Appropriateness/Demolition/Exemption by the Old King's Highway Historic District Committee for the following project: C S a✓192,Y,4b &I 516+ Kew- Date: 2/2/2024 ECFIVED FEB 0 8 2024 I M1l1YlVV I r, Signed: Owner Owner Contractor/AgepW e2q --/vb GENERAL SPECIFICATION SHEET Project Address: 16 Church St, Yarmouth Port, MA 02675 FOUNDATION: Material: Exposure (Not to exceed 18"): CHIMNEY: Material/Color: GUTTERS: Material/Color: ROOF: Material: Asphalt Pitch (7/12 min) 9112 Height to Ridge: Color: Tan SIDING: Material/Style: Front: Sides/Rear: COLOR CHIPS Color: Front: Sides/Rear: TRIM: All windows & doors to be trimmed with: 1x 4 1x5 (Circle one.) Material: Color: DOORS: Qty: Material: Color: Style/Size (if not listed/shown on elevations): STORM DOORS: Qty: Material: GARAGE DOORS: Qty: MatT Style: WINDOWS: lslde:: Front: Left: Manufacturer/Series: Grilles (Required): Pattern (616, 2/1, etc.) _ Snap -In: Between Glass: Color: Color: Right: Rear: Color: Material: _ Grille Type: True Divided Lite: Permanently Applied: Exterior Interior STORM WINDOWS: Qty: Material: Color: SHUTTERS: Mad: Style: Paneled Louvered Color: SKYLIGHTS: Qty: Fixed Vented Size Color: FEB 0 8 2024 0ANIVIOU I r, OLD KING'S HIGHWAY DECK: Size: Decking MatT Color: Railing MatT Style: Color: WALLSIFENCES* (Max S' height): Height: MatT Style: Color: (Show running footage & location on plot plan.) *Finished side of fence must face out from fenced in area. UTILITY METERSIHVAC UNITS: Location: LIGHTS: Qty: Style: Location(s): Screening: Color: LIGHT POSTS: Qty: Material: Color: Location(s): 16 Church St, Yarmouth Port, MA 02675 Additional information: Install 17.00 kw Hanwha 425 solar panels on roof. 40 total panels. No battery. No structural. Panels may be partially visible but will not significantly impact public way. 2-General APPLICATION #: TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE ABUTTERS' LIST Applicant's (Owner) Name: Peter Barnes Property Address/Location: 16 Church St, Yarmouth Port, MA 02675 Hearing Date: Notices must be sent to the applicant and abutters (including owners of land on any public or private street or way) whose property directly abuts or is across the street from the applicant. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website: www.varmouth.ma.us Map Number Lot Number Applicant Information Abutter Information: RECRVED FEB 0 8 2024 r HHIVIUO l r, MIS 153C,1 i92t -73 15360 -7 D 53 (0 -71 15 3 (aL 5151 Application* 941 AD X 1221 73► r 1 ROBINSON DOUGLAS C ROBINSON MARY C 4 CHURCH ST, YARMOUTH PORT, MA 02675 1221 721 r 1 LEVINE HAROLD C/O BARNES PETER A 16 CHURCH ST YARMOUTH PORT, MA 02675 1221 711 1 1 MELLOR MARCIA 24 CHURCH ST YARMOUTH PORT, MA 02675-1101 1221 701 1 1 MELLOR MARCIA 24 CHURCH ST YARMOUTH PORT, MA 02675-1101 1221 661 1 1 GRADER ABRAHAM S GRADER MICHAL H 17 CHURCH ST, YARMOUTH PORT, MA 02675 Please use this signature to certify this list of properties directly abutting and across the street from the parcel located at: 16 Church St., Yarmouth Port, MA 02675 Assessors Map 122, Lqt 72 Andy LWchado, Director of Assessing February 23, 2024 RECEIVED FEB 2 3 2024 �Amvi V V ! n v (. J1 r1�r � O -t ,7o_A6>0 u� n a fV � '� •e Y � v y se f r f• RF -VI o r r} g 2024 I �Hf-1IVlUillh _ �D JNG' H1 HWAY 2 d N N d CV a Mo 3 H �k g ETT yx, i' €3 }� N 05 °' t, a •� °' Noun 4 oj ga °C) {.� X u 3 0 = St 0 Gh'�� , 'h w , ❑ 0 0 9 RECFIVFt-., FEB G 8 2024 (Ahiviuu i r, i .1 W FtOV%t of Huse 3 Y EIT 1 *4C\ 0 NaM09 94-Ab;to g 7 aC c fA 'C m a 3 FF U 8 E FI VE D `P 0 8 2024 fAmivjuV I fi 4SETT c. NW1P1 E- �c qq'A;�o S v� z P Q 0 J z 0 a 0 N Q1 0 0 v N C a _ a E E 3 � Ln � a c u N � N � Ln L U N m @ o �- a � u O o � m w c a o z N °1 nj o E - F rn E c m w w E Q- 0 E Q r M d c „ ul N mr E Ea d .E � mE co^ Ev E v ^M c�i a N,n 0 x �O coE V c o c°n D t= �p a y 00 M p E 70 00 r: n o-' n .� - o cn E m ,o s. v o V rn ,o � 'n a N 0 v° ° g � U m c o W 0 0 0 LL 3LL cooLL U� uv Rl OLD KlNG'S HI li{1riEi - � .! i• ,�'� '} ] � �, i,E :i L� i IH��� :fi '$il fi , r '=:I �iit �IN fiEl.=f., 11 j j fit «A i WAY J _ 1 z Y W� W1 W 1 ZZ w �_,� §10_INV A I f� Sd<?Y a L RA m 0a SETT _ ` o glut g ��1TR09 ` RF— 09VIED 8 2024 ...I- )loin r) O •W 0 LL �WM"15 it �Fzmb .1 xa � a C=RH 9 fli t oZO�i mMSE-20' RWN T-1EIr HI or� r- � g $ t c 0= .. r Alf Nofi10� RECEIMD FEB 4 R 2924 MI LO ul N�rno� N N OM M N N N `u V A 7 C E 0 Z eo G = N U 3 V S r EB 0 � 2024 AP' ?4-ACPD s 44 w f�4 f�4 r4 F4 r4 t E 3 G 3 �940IZ- ao5;F N L C a NM� NM� z a � I I .A tI e C lip E .,, � 4 Q QJ O � N Z 4 wa zm 0 0 0 ,n Q{; I Z � Lf) OR Z Li1 DECEIVE FEB Q S 2024 YAAlvfUU'I r, OLD KING'S HIGHWAY z � J m f •��de F yU u 08C j � J — a J�Z f z 5� mta L yy8 — Z L ,9L4,Al—) E-CEIE FEB () 8 2024 'f Aty,vriUu i n m m O O - N - - O O O O O O O o S d 0 0 0 a a4 04 m oc [G1 f1 [G] a m Y V Y a m Y Yg mY V 9 � _U _U ,� (O a J ti A m R P O 71 p mQpa �aa�g v_ma o w o 8 q{Gs� 3 L a u a $ w Z w z w C C c W ww� W w W U fCa- G C LL O w W a is n m >_. W m 7 m N N R IL oD N 1D O Y V N Z LL O O O O O O O O O O O O O CD LL g Op a C a V t n. • in c c LL "' oo c CC m Q O C Ja w en �e g q c a a v m 2 v 99 4 N t&~ p c c c QQ m p V Q N o m x Z A V x t Q u a L ... V} a_ u V T m c = E v c m L° w w a# w E Z j m tl1CD 2 ur N io N m P a° g y U p G m G G U o v m 4! t! 1! m $ U. LL s 3 � I u A0 ,140?-D 9EMOVED FER 0 8 2024 rr 1� It1r, .� �.....�ir a rir•__.Gll m v 44 _ �.�, 96. L m $ o ; to a�IAg a 00 `' °I k � � � � �■ . L ` . �� •� � e � a CL\ AP scrr f � I l i 0 8 t RO , O -4 F. FEB 0 8 2024 r F11 SrJltlU I r4 1 OLD KINGSV To d "1 Ai ii VL1 :I V � Ij PET :. FEB 8 2024 'rARVIOUT h OLD KINGS HIGHWAY 2 0 m F I foh pF op Nil Al Fi ' V. - - '!i-il• of * , 1 '• r 1 �T f�� 5i f .� rs\ ;S,"' ? pia`••," .eY'i,' I e �~ ��tF'}:l,;Hy. 4 4} 4,ti � • i" .�# n � 'fir. ri � . �nK . 1. V* I rll�' it � v � 1'4 s ��.�� '. fir+ �•,. +1 1,� 3: a%' �.� ?� fix• �` 3'F4{ }' ` - �k * } , 'I fs 1 -i AI w .A. 4 # � rt '/`'. ��� r.`�, �: {�* T l�C•/ 1*al �'*fV• � •. r ,fir �y .w� ya Ak �,.. wd Af T. • ? fir;r. ' '! °I' +] .' - k. or 1 b e y r� r S !•i ref. L �`•}"''T `t .III+F�+�� •yi�rs: JS IW 01, IX AA or JL At �� isr 'rNF �,�� x ` r � � •r 'j � � ,y' i. � �lJ f•' � * # 14 ;� t . _ � ".. �✓w Ia' - ., , `', file ► • 1f �q , DocuSign Envelope ID. 87072771-72294F22-AE4D-486D8AA20AF Dmusqn.d by. Aurora Shade Recr#,,,A0DD,A,.24..t, V baMA S Customer Peter Barnes Address 16 ChurCh 5t YarrnoUln Port MA 02675 Annual irradiance FINAL DESIGN Designer Vpul Pradhan Coordinates (41 707052, -70 2426381 DEB I'D 8 2r'4 `e� E-I11 E 0 Organization I FEB 0 8 2024 venture Solar LLC (At iivi�)u f t-, Date OLD KINGS HIGHWAY kWhlm2/Year 2,450 or more 2,100 1,750 1.400 1.050 700 350 0 -� 2 .January 2024 Summary A►ray Panty Carmt Azirnwh (dog.) Pitch (d".) Annual TOF (`k) Annual Solar Accra (%) Amual TSRF (4 } 1 18 72 37 70 85 60 12 252 37 85 82 70 3 5 162 37 99 69 69 1 5 72 23 76 81 61 WerpMad average by panel count - - - 81.7 64 Peter Barnes ENPHASE DATA SHEET IQ8M and IQ8A Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the micro'nverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included O-DCC-2 adapter cable with plug-n-play MC4 connectors_ IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an Industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. ® 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, I08 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01- EN-US-2022-03-17 FEB 0 8 2024 YARMOU-I i-. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two -wire cabling High productivity and reliability • Produce power even when the grid is down' • More than one million cumulative hours of testing • Class II double -insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support" • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21(UL 1741-SA) requirements • Only when installed with IQ System Controller 2, meets UL 1741. •' 108M and IQSA supports split phase. 240V installations only. IQ8M and IQ8A Microinverters INPUT DATA r ,: Commonly used module pairings' W 260 - 460 295 - 500 Module compatibility 60-oelf/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -call MPPT voltage range V 33 - 45 36 - 45 Operating range V 25 - 58 Min/max start voltage V 30 / 58 Max input DC voltage V 60 Max DC current2 [module Isc) A 15 Overvoftage class DC port it DC port backfeed current mA O PV array configuration OUTPUT i 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 330 386 Max continuous output power VA 325 349 Nominal (L-L) voltage/range' V 240 / 211- 264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 AC short circuit fault current over �I1^. "HS. #yR�+ Fr!_ j Y� 1 r_L 2 , 3 cycles Arms Max units per 20 A (L-L) branch clrcult4 Total harmonic distortion <596 Overvoltageclass AC port III ' OLD KING 5 1 iI6.'.`0'vAY AC port backfeed current MA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85leading - 0.85 lagging Peak efficiency % 97.6 97.6 CEC weighted efficiency % 97 97.5 Night-time power consumption mW 60 Ambient temperature range -400C to +60°C (-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions (WxWxD) 212 mm MY) x 175 mm (6.9") x 30.2 mm (1.2") Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - no fans Approved for wet locations yes Pollution degree PD3 Enclosure Class II double -Insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), UL 52109 1, UL1741AEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Certifications This product Is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014. NEC 2017, and NEC 2020 section 69012 and C22.1-2016 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when Installed according to manufacturer's Instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://Ilnk.enphase.com/module-compatibility (2) Maximum continuous Input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch In your area. 108MA-DS-0003-01-EN-US-2022-03-17 ;X4_10;V 01/25/2024 Peter Barnes 16 Church Street Yarmouth Port, Massachusetts 02675 Re: Solar Panel Installation Dear Mr./Ms. Barnes, At your request, Patrick Bussett of Venture Solar LLC (MA license #56934), has carefully reviewed the existing roof framing and the proposed connection of the solar panels to the roof for the building referenced above. The following building codes were used in conjunction with the 9th Edition of the Massachusetts State Building Code — 780 CMR to generate pertinent design criteria: ASCE 7-10 — Minimum Design Loads for Buildings and Other Structures International Building Code 2015 Edition (IBC) National Design Specification for Wood Construction 2015 Edition (NDS) Design Criteria: Design Gravity Load: Snow/Live Load = 30 Ibs/ftz, Dead Load = 12 psf Design Wind Load: Vuh = 140 mph; Exposure B, Risk Category II "Wind loads exceed seismic loads and therefore govern the design Field observations identified the following conditions: The new solar panels will impose an additional dead load of approximately 3 psf. Roofs A, B & C consists of asphalt shingles over plywood sheathing supported by 240 rafters at 16" o.c. The rafters are sloped at a 36' pitch and have a maximum projected horizontal span of 17'-0"±. Roof D consists of asphalt shingles over plywood sheathing supported by 2x6 rafters at 24" o.c. The rafters are sloped at a 38' pitch and have a maximum projected horizontal span of 16'-0"± with an intermediate knee wall support. The framing is assumed to be Douglas -Fir #2 graded or better. The calculations determined that the existing framing has adequate capacity to support the PV panels as shown in our PV panel layout plan with no structural upgrades required. I therefore certify that this installation complies with the applicable codes and is acceptable for approval. Please feel free to contact me if you have any questions or concerns. Best, I oo_ Patrick Bussett, PE Email: patrick.bussett@venturesolar.com FFB -9 8 2924 / -`,)h?v 0 �i L W IMP H IA 7 C N r� W V D cl 0 �c a J J 3 CL �J 0 0 s 0 c- ro V) (1) S v L FD u m w a a w a? FEB 0 8 2024 Hrtiwuu I r-t i 94_A);O laws LA 0 s 0 0 IM N 0 u Ln 0 0 = a� - L I u CD � 0 i DocuSign Envelope ID; 87072771-7229-4F22-AE4D-4486D8AA20AF _4ont re solar Letter of Authorization / Property Owner Authorization Form I, Peter Barnes, am the owner of the property located at address: 16 Church St, Yarmouth Port, Massachusetts 02675 hereby authorize Venture Home Solar, LLC dba Venture Solar Power of Attorney to handle dealings associated with the successful interconnection and application for obtaining local building and other permits from the Authority Having jurisdiction as required for a Solar Photovoltaic System located on my Property. I further authorize you to release my account information for the prior twelve (12) months, including electrical usage and demand history. Venture Solar agrees to keep this information confidential and use it only for the purposes of designing, installing, and interconnecting my photovoltaic system, obtaining incentives on my behalf, and establishing interconnection agreements, proper metering, and approvals. Print Name: Peter Barnes UocuSigned by: i Owner Signature: 1pthr b"W's Ct Enono,A6e64z4. Date: 1/19/2024 Print Name: Peter Barnes OocuSigned by Utility Bill Owner Signature: Fpdv t ouAls :'vA-0D1A6B6424 Date: 1/19/2024 1=EB e S 2024 DocuSlgn Envelope ID: 87072771-7229-4F22-AE4D-4486D8AA20AF Fenture solar Venture Solar Damage Liability Addendum for PV Installations Customer: Peter Barnes Installation Address: 16 Church St, Yarmouth Port, Massachusetts 02675 Venture is liable to pay for damage to your real property caused by our negligence during your installation. We shall not be liable for damage to the system's installation area due to old, deteriorated, or improperly installed roofing, sub -roofing, roof coverings, supports, siding, exterior paint or covering, or other non -visible installations. In the event that you suspect there may be damage to your property caused by our installation please contact us immediately at 347-305-7999 or email supportftventuresolar.c om to schedule an on site inspection of the damage. Venture may elect to hire a sub -contractor to repair the damage. After we conduct our inspection of the alleged damage, we will contact you with a plan to correct the damage. If you elect to use a contractor other than Venture to repair the damage without written consent from Venture, we reserve the right to not reimburse you for the damages. Our total liability shall be limited to the amounts due payable to Venture under your agreement. Except as set forth in this addendum, you agree there are no oral or written representations or inducements, expressed or implied, any way conditioning this addendum, and we expressly disclaim their existence. By signing this addendum, you acknowledge that you have read and understand this agreement or have had a competent legal representative explain its terms, and hereby accept this addendum in its entirety. You further acknowledge receiving a complete copy of this agreement. Loocu8lpnedhy: CEIE 1/19/2024 P CIERODDIABB8424 FEB' 0 8 2024 Signature Date 9 LK/jUJa support@venturesolar.com 347.305.7999 DocuSign Envelope ID: 87072771-7229-4F22-AE4D-4486D8AA20AF ik, re solar Venture Solar System Removal Addendum for Residential PV Installations Customer: Peter Barnes Installation Address: 16 Church St, Yarmouth Port, Massachusetts 02675 If you elect to have your solar energy system removed and re -installed in the future there will be a charge of $325 per panel to remove, store, and re -install the PV system. If you elect to have the system removed, but not re -installed there will be a charge of $220 per panel. This pricing is valid for 120 months from the date of signature. Venture guarantees the penetrations related to the solar PV system and the area 6" around them for 10-years, but takes no responsibility for the roof or it's integrity otherwise. Except as set forth in this addendum, you agree there are no oral or written representations or inducements, expressed or implied, any way conditioning this addendum, and we expressly disclaim their existence. By signing this addendum, you acknowledge that you have read and understand this agreement or have had a competent legal representative explain its terms, and hereby accept this addendum in its entirety. You further acknowledge receiving a complete copy of this agreement. IPOocuSlpnad by: ��'t.v' 15"VO-S CI EAODWABBU24 Signature 1/19/2024 Date In the event that you suspect there may be an issue with your roof, please contact us immediately at 800-203-4158 or email support@venturesolar.com to schedule an on site inspection. s F[-B 0 8 2024 , V ,'JIi- - , support@venturesolar.corn 347.305.7999 DocuSign Envelope ID: 87072771-7229-4F22-AE4D-4486D8AA20AF ven 1 1 +re solar Venture Solar Customer Agreement Addendum for Electrical Work Name: Peter Barnes Address: 16 Church St, Yarmouth Port, Massachusetts 02675 This electrical addendum ('Addendum") is in connection to and made a part of the Solar Electric Installations Agreement ("Agreement") between Venture Horne Solar LLC {"Venture") and Peter Barnes ('Owner') to take place at 16 Church St, Yarmouth Port, Massachusetts 02675 ('Site'}. Venture and Owner may individually be referenced herein as a'Party' or collectively as the 'Parties'. The Parties agree as follows: 1. In addition to the electrical work stated in the Agreement, Venture shall complete additional electrical work as follows: TF Tap Box p 2. Venture offers a 10-year workmanship warranty. Q 8 44 3. The total cost of the electrical work is $1,135.00 4. Venture will remove all debris and garbage from the site. -OLD (1�If1JVIU0 i i hCl�[G.S f�ilCtiyW�� S. Venture will make its best efforts to complete the work within 24 to 48 hours of the scheduled date but is not liable for any delays due to permitting, policy change, weather, or force majeure events. While performing the Additional Work, Venture may discover certain undisclosed or unidentified Issues. Any costs related to those items are specifically excluded from this proposal. Owner and Venture shall execute a change order addressing those items. 6. Owner to supply all electricity at the Site and represents that the existing electrical system at the Site is in full compliance with the current National Electrical Code. 7. Venture shall furnish all tools, equipment, supplies, superintendence, transportation, and other construction accessories, services and facilities necessary for Venture to perform the Additional Work. Venture shall furnish all material, supplies and equipment specified to be incorporated into and form a permanent part of the Additional Work. Venture will provide and perform all necessary labor in connection with the Additional Work in a professional and skillful manner. 8. If the project is not substantially complete within 180 days of the execution of this document, the Owner may cancel with no penalty. g. Customer Payment of $0 due on the day the Additional Work begins. 10. In the event Venture determines that any of the Additional Work outlined in this Addendum is not necessary, Venture may elect not to proceed with those portions of the Additional Work. Venture will inform the Owner of the Additional Work that isn't going to be completed and reimburse Owner for any out of pockets costs incurred. Venture Home Solar, LLC -Dmuftmd by: �ttt,lr jrJat VOIS Owner LLLLL c,EA0oDIAOB8424 94, A%?V DocuSi&n Envelope ID: 87072771-7229-4F22-AE4D-4486D8AA20AF tur,- sear Our Cancellation Policy, Explained While we never like to see anyone go, we understand that things can happen to change circumstances and we want to be as transparent and clear as possible about the policy around cancellations. The following form attached is the only acceptable method of cancellation agree that if I cancel outside of the cancellation window associated on the next page that I will be liable to pay the charges associated and I cannot refuse to pay. If I refuse to pay, Venture's legal team will pursue legal action. ,DS Initial P15 I agree that the only acceptable method of cancellation is to send the cancellation form to canceirequest@venturesolar.com DS Initial rb 1 agree that I cannot cancel verbally with any team member under any circumstances. If attempt to cancel verbally with any team member it will be considered null and void Lp S Initial I agree that if I am canceling based upon a competitor providing a lower price, I am willing to allow Venture an opportunity to price match the previous offer. Venture has a price match guarantee and will pay $500 toward another company if we cannot match the other quote apples to apples. DS Initial If you are outside of 7 days, I agree that I need to speak with a member of cancellations team in order to process the cancellation Initial PCti r yP�'p"`L: LT 2n:4 r �lr .ri 1lil r OLD KINGS HIGHWAY DocuSign Envelope ID: 87072771-7229-4F22-AE4D-4486D8AA20AF Fentu re solar Venture Solar Customer Cancellation Addendum This addendum is in relation to the solar photovoltaic installation agreement ('Agreement') between Venture Home Solar, LLC ('Venture') and Peter Barnes ('Owner') to take place at 16 Church St, Yarmouth Port, Massachusetts 02675 ('Site`). Venture and Owner may individually be referenced herein as a 'Party' or collectively as the'Parties'. TRANSACTION DATE: YOU MAY CANCEL THIS TRANSACTION WITHOUT ANY PENALTY OR OBLIGATION, WITHIN SEVEN (7) BUSINESS DAYS FROM THE ABOVE DATE. TO CANCEL THIS TRANSACTION, FOLLOW THE INSTRUCTIONS IN THE SECTION BELOW. The following cost schedule is enforceable if the Owner chooses to cancel their project: Cancellation Timeline • Within seven (7) days of signature • Between eight (8) and thirty (30) days of signature • Outside of thirty (30) days of signature • Within two (2) days of scheduled installation Fee;,- n. $1,275.00 �8 0 8 2024 $2,675.00 • ri1�IJ1tiJ�J i $4,750.00 oz Kl G'S Hl ' k AY Your signature below indicates your agreement to the timeline and fee schedule in the event you choose to cancel your project post signature. Docu ftnW br. p!.iv 15AVVI)IS Signature 1/19/2024 Date In the event that you wish to cancel, please sign below and email a copy to cancelrequest@venturesolar.com. The cancellation fee will be based on the date above and the date that the copy is received via email. I, Peter Barnes, wish to cancel my solar installation with Venture Home Solar, LLC and agree to pay the fee associated based on the time passed from entering the installation agreement. Signature support@venturesolar.com Date 347.305.7999 Ln r- kD N O LU N V Ln LA 2 t t= LIWUM ... s L C CU cu c E CD Ch rA -I Ln LU m0 a ai A O v A G1 c a o � p 4-J C C a, E CL_0 • _B 0 S 2024 4 .� V r (V C ri it NJ ifs 4 N V L 0 4-J v c � � a� 0 0 0 V) }' u :S L a � j a C N N W mC to 4 � a4 C •C a � uIIe O -0 L� V fo L1 m LO v N L cr i � L m C O ' L L 4- Qj a a1 � r m 94Jt&`" DocuSign Envelope ID: 87072771-7229-4F22-AE4D-4486D$AA20AF @ 0 HomeWorks min Energy Venture Solar & HomeWorks Energy Partnership Venture has partnered with a local Mass Save Energy Efficiency contractor to maximize savings available to our customers who are choosing to switch to solar. As a part of this partnership, you are eligible to have a free home energy audit that will include no cost energy efficiency upgrades. During the energy assessment we will determine which upgrades you are eligible for. The assessment is a short, painless process that we can help you schedule online. This is an option available to you at no cost, and is in no way required for your solar project. Most of our customers find this to be a valuable service if they have not already had a home energy assessment. After your assessment, you will receive a report. You will be eligible for no cost air sealing, and have options for weatherization measures with a nominal co -pay if you elect to have those measures installed. You can begin scheduling your home energy assessment here: https://www.homeworksenergy.com/corporate/venture-solar FEB 0 s 21124 Hruviuu i ri 1_0 KIN 'S HIGHWAY O�p DocuSign Envelope ID: 87072771-7229-4F22-AE4D-4486D8AA20AF venture� solar FEB �09 8 2024 Referral Program S IJ' QI.D KING'S HIGHWAY In our tier based system, you earn more for referring more people. Starting with $500 per referral, you move up tiers to make up to $1,000 per referral. ❑ Yes, enroll me ❑ 1 don't want to help my friends / family ❑ I don't have friends Referral l: Referral Z: Referral 3: Referral 4: Referral 5: ..:IEAaDuiA686424 Bronze Tier: 1-3 referrals $500 each Silver Tier: 4-5 referrals $750 each Gold Tier: 6+ referrals $1,000 each DocuSign Envelope ID: 87072771-72294F22-AE4D-4486D8AA20AF venture Sotar SCHEDULE E Energy Usage and Billing Assumptions Customer: Peter Barnes Installation Address: 16 Church St, Yarmouth Port, Massachusetts 02675 FEB 0 s 2" (A- wev, . Our goal at Venture Solar is to provide the best customer experience possible by delivering the highest quality installation and service. We also strive to set proper expectations about your solar energy system's expected performance and its effect on your future energy usage. Venture Solar uses the historical energy usage information made available by the customer to calculate the annual energy kilowatt-hour (kWh) needs and to design the most efficient System possible to reduce the energy needs from your utility provider within the bounds of any local rules and regulations. There may be adjustments to the estimated energy needs based on input from the customer such as, but not limited to, purchasing an electric vehicle, upgrading appliances, or a change to the number of people living in the home. Customer acknowledges that Venture determines historical and future energy needs to the best of its ability based on the information provided but makes no promises or guarantees related to how much energy the customer will use in the future. Estimated remaining energy needs from your utility provider are an estimate based on the energy usage in kWh displayed on your proposal. If your energy usage increases or decreases, it may affect the percentage of energy in kWh that is provided by your System and resulting utility bills. Customer acknowledges that utility rates fluctuate and will likely increase over time. If utility rates increase, the resulting remaining energy in kWh that the customer needs beyond what the System produces may cost more than originally presented in your proposal. For any avoidance of doubt, if the cost of power with your utility company increased by $0.05 per kWh and you needed 1,000 kWh annually beyond what your system energy system produced, you would pay approximately $50 more per year than expected at the time your proposal was calculated assuming no other changes in your utility billing structure or plan. Venture Solar includes an assumption of utility rate increases when we calculate your lifetime savings. Names) Peter Barnes •.._ .C'1MDD1AGB5424 Signature 1/19/2024 Date Sherman, Lisa From: Mary Robinson <marycrobinson@yahoo.com> Sent: Sunday, March 3, 2024 10:31 PM To: Old Kings Highway Subject: Solar Panels Yarmouth Port North of 6A Attention!: This email originates outside of the organization. Do not open attachments or click links unle:. you are sure this email is from a known sender and you know the content is safe. Call the sender to verify if unsure. Otherwise delete this email. Dear Historic Committee, I was shocked to receive the request for variance to add 40 solar panels to a roof that abutts my property in the historic district of Yarmouth Port! My property will be impacted by the glare and this addition detracts from the historical quality of the neighborhood. This addition will also set precedent for future modern additions and solar panels. Recent research has shown that degrading solar panels leach lead and cadium into the atmosphere posing an environmental debate. As the committee that protects the historic architecture of this lovely area I hope you will decline this request. Douglas and Mary Robinson 4 Church Street Yarmouth Port MAR a 2024 iH!twiUUIr 9L& 1 v " Sherman, Lisa From: Robinson <marycrobinson@yahoo.com> Sent: Monday, March 4, 2024 8.00 AM To: Old Kings Highway Subject: Do Solar Panels Kill Birds? Uncovering the Surprising Truth - Anker US Attention!: This email originates outside of the organization. Do not open attachments or click links unless you are sure this email is from a known sender and you know the content is safe. Call the sender to verify if unsure. Otherwise delete this email. Dear Kings Highway Committee, Here is a concerning article on the negative effects of solar panels on water fowl. In addition to historical concerns the « sides » of the 16 Church Street property to be fitted face 6A and are also visible from Church Street. https://www.anker-com/blogs/solar/do-solar-panels-ki11-birds Thank You Mary Robinson 4 Church Street Yarmouth Port Sent from my Whone MAR OLD KING'S HIGHWAY qt'�-At�?b Do solar panels kill birds? Do solar panels kill birds? Solar panels, both in residential and in solar power plants, do not kill birds outright. However, it has been observed that some birds are somehow attracted to the shininess of solar panels, which can resemble moving water when seen from above. Aquatic bird species, in particular, may mistake the panels for bodies of water and attempt to dive into the "water," resulting in injury or death. Despite this issue, it's worth noting that solar panel -related bird deaths are often exaggerated. In residential areas that are not close to large water bodies, this problem is less likely to occur. Researchers are currently using Al technology to track and monitor bird species that are prone to diving into solar panels, with the aim of preventing such incidents. Importantly, even the National Audubon Society, a nonprofit organization committed to bird and bird habitat conservation, supports solar power, indicating that the benefits of this renewable energy source outweigh the potential risks to birds. How do solar panels kill birds? Here we go again with the million -dollar question of "how do solar panels kill birds". Let's dig in? Solar panels can potentially kill birds through a phenomenon known as the "lake effect." Migrating waterfowl and shorebirds may perceive the reflective surfaces of photovoltaic (PV) panels as bodies of water and collide with the structures as they attempt to land on the panels. However, it is important to note that the effect of solar panels on bird mortality rates is relatively low compared to other causes, such as collisions with buildings, vehicles, and power lines or predation by domestic cats. Utility -scale solar energy facilities, particularly concentrated solar power (CSP) towers, can also pose a threat to birds. CSP towers use mirrors to concentrate sunlight onto a central tower, generating intense heat. Birds attracted to the light beam or the mirrors may be killed by the extreme heat generated by these facilities. However, the overall impact of solar energy on bird populations is still considered to be much lower than that of fossil fuel industrial facilities: -power plants, which can cause bird mortality through collisions, electrocution, and poisoning. What to do to prevent killing birds when installing solar panels? To prevent bird deaths when installing solar panels, consider the following steps: 1. Choose the Right Location for Your PV Solar Panels Select a site that is not in a known bird migration path or near a nesting area. Avoid installing solar panels near wetlands, rivers, or other bodies of water, as these are often critical habitats for birds. Also, consider placing your solar panels on rooftops or other existing structures to minimize the impact on the surrounding environment. 2. Avoid Using Reflective or Mirrored Panels Reflective or mirrored solar panels can confuse birds, causing them to collide with the panels. Instead, opt for solar panels with a matte or non -reflective surface, like the Anker 625 Solar Panel, which has a lower risk of causing bird collisions. $60 OFF Anker SOLIX 10OW Foldable Solar Panel $239.00$299.00 Code: WSTDBDMPELCOPY High Conversion Efficiency: The solar panel converts up to 23% of sunlight into solar energy, charging your solar generators even on cloudy days. Smart Sunlight Alignment: Equipped with Anker's proprietary Suncast technology, adjust the solar panel properly to capture direct sunlight for maximum charge. Made for PowerHouse: Anker 625 Solar Panel is compatible with PowerHouse 521, 535, and 757 (sold separately), making it an ideal all - in -one power solution for road trips, camping trips, RVs, and more. The lightweight solar panel features a USB-C and a USB-A output port to charge 2 devices at the same time. Highly Durable: The solar panel is scratch and weather -resistant to last as long as your adventures do. What You Get: Anker 625 Solar Panel (100W), solar charging cable, XT-60 To DC7909 connector, welcome guide, our 18-month warranty, and friendly customer service. Learn More Buy Now But wait, there's more! Boost your daily activities with the high -conversion efficiency capability of the Anker 625 Solar Panel, converting up to 23% of sunlight into solar electrical energy. Featuring our Suncast technology for smart sunlight alignment, it's compatible with PowerHouse 521, 535, and 757 (sold separately). Ideal not only for home use but also for road trips, camping, and RVs. The lightweight panel offers USB-C and USB-A output ports for dual device charging. It's scratch and weather - resistant, so you can ensure that it can withstand the test of time. 3. Install Anti -Perching Devices Birds may perch on solar panels or the structures supporting them, increasing the risk of collisions or entrapment. Installing anti -perching devices, such as bird spikes or sloping covers, can help discourage birds from landing on your solar panels. 4. Maintain a Safe Distance Between Panels 2-Uq " Leaving enough space between solar panels can help prevent birds from becoming trapped between them. Ensure that the gaps between panels are either too small for birds to enter or large enough for them to escape easily. 5. Use Bird -Safe Netting or Mesh If you need to install solar panels close together, consider using bird -safe netting or mesh to cover the gaps between them. This can help prevent birds from becoming trapped while still allowing sunlight to reach the panels. 6. Install. Visual Deterrents Visual deterrents, such as bird -scaring tape or predator decoys, can help discourage birds from approaching your solar panels. Be sure to change the location of these deterrents regularly to maintain their effectiveness and prevent solar panels killing birds. Conclusion To wrap up, while solar panels have been associated with bird fatalities, the overall impact is minimal compared to other human -induced threats. By taking responsible steps in solar panel installation and maintenance, we can utilize the power of the sun while preserving our avian friends' safety. Embracing solar energy as a sustainable, clean power source is essential in the fight against climate change, and with continued research and advancements in technology, we can strike the perfect balance between harvesting renewable energy and protecting bird populations. So, let's soar towards a brighter, greener future, hand in wing with our avian allies! Here are some commonly asked queries about "Do solar panels kill birds". Do solar panels attract birds? Solar panels do not inherently attract birds, as they do not emit any signals or produce food sources that would entice them. However, some birds may find the flat surfaces of solar panels suitable for nesting or perching, especially if the panels are installed near trees or other natural habitats. Is the disposal of solar panels bad for the envi ronment? The disposal of solar panels can be harmful to the environment if not done correctly. Solar panels contain materials like cadmium, lead, and some other heavy metals that can be toxic if released into the environment. Proper recycling and disposal methods are essential to minimize the environmental impact and ensure that valuable materials are recovered and reused. Can birds damage solar panels? While it is relatively rare, birds can potentially cause damage to solar panels. They may peck at the wiring or scratch the surface of the panels, which can result in reduced efficiency or even malfunction. Additionally, bird droppings can accumulate on the panels, reducing their ability to absorb sunlight and produce electricity. Regular maintenance and cleaning can help prevent and mitigate any potential damage caused by birds. Featured Articles I;Q,Ab?O