Loading...
HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 20.9'± PROPOSED EXTENSION RISER WITH COVER OVER INLET & FINISH GRADE OUTLET TO WITHIN 6" OF F.G. @ FND. EL.= 19.8'± F.G. OVER TANK EL. = 19.5'# . w. PROPOSED 4" v'R -- - - SCH. 40 PVC _...v.._..,'...o-.- SEWER PIPE 3 DROP MAX - - 6�, 3" ,,�� none MIN 3„ 9„ M1N. SLO E 1 FRACTOR SHALL =Y CONDITION OF \ OUTLET TEE PING TEES GAS BAFFLE REPLACE AS :SSARY ° 3 SWING -TIES & DIMS. SCALE: 1" = 20' SWING -TIES DESCRIPTION HCA HC-2 DC CORNER OF STONE (1) 20.4' 68.6' 24.3' CORNER OF STONE (2) 32.1' 79.4' 35.0' CORNER OF STONE (3) 42.6 73.5' 34.4' CORNER OF STONE (4) 34.6 61.7' 23.6' f NOTES: i 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT 1 DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. v 3. ENTIRE PROPERTY IS LOCATED WITHIN A MASS DEP ZONE il. 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. �RETE SEPTIC TANK FINISH GRADE OVER D-BOX = 18.1'± I REMOVABLE WATER -TIGHT COVER OVER ' RISER TO WITHIN 6" OF FINISHED GRADE i 5" DIA. OUTLETS) ! I 9" MIN. 36" MAX. I L=401t PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS (TYP.) ( SEPTIC TANK • 4" PVC OUT TO LEACHING FACILITY , j 12" 6" 14.80' MIN. \-14.63' 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE ' 5 OUTLET DISTRIBUTION BOX ! TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL CROSS SECTION VIEW NOT TO SCALE FINISH GRADE OVER CHAMBERS = 18.2' - 17.0' 3/4" TO 1-1/2" DOUBLE WASHED SLOPE @ 2 /o MIN. OVER SYSTEM STONE TO CROWN OF PIPE - 4" SCHEDULE 40 PVC MIN SLOPE 1% 2" OF 1/8" TO 1/2" DOUBLE WASHED I STONE OR GEOTEXT LE FILTER FABRIC T L E iTOP OF SAS = 15.50' PLACE RISER ON ALL 9" MIN. F 14.5Q' 36" PJ4AX. BREAKOUT EL = 15.00' -� j CHAMBERS TO WITHIN 6- INLETS OF F.G. - i 1 d �,45.36 .00 \ 660, EX. TREE TODE y �� Of \ RE!"'O `ED (TYP IN RED) G� o (� �^ f,EY. O . r= ` .'IEEE �. l Ij PROPOSED TWO 2 500 17 / = / { u •�� _ GALLON H-20 LEACHING 12" CHAMBERS w/ STONE A3.5' 8.5' (TYP) 12.50' GROUND WATER ELEV= Mai (TYP.) 11 83' 2 - 500 GALLON H-20 CHAMBERS \-5' MIN. CHAMBER END VIEW TYPICAL CHAMBER PROFILE , e ! .� . A T� � 3 4 \ :,� 18 s3 5 1 II `"t 3 r'�\�' „ � .,. CZ ��C7..,..t,, 1 �-..`` �`. `"'/ � / 7" �✓ R,.a..i"` ,61 j PROPOSED H-20 (p i' % DISTRIBUTION BOX yftg4 t a 2-BEDROC".i ( \ = DID' ELL1NG rn 0 \ MAP 45 TGi -2c.° -�__ MAP 45 m M \ LOT 7 ( LOT 79 18,797t S.F. , \ ij a, N .� 0 0 1 20- :106 bo U-) ` p x t "'As GAS v- S Benchmark 18' S0^E __-'' �_! ;- v_ Nail in 12" Tree o -,.ti i ) 86'S4 Elev. = 20.00' 6 Approx. M.S.L. _. MAP 45 ' LOT 8 SITE PLAN SCALE: 1" = 20' rn C� N m Q NOT TO SCALE d / b �}} t •/•t 1� {, ��"�� ,/` / r.l'- I i i _ a; r I i s, 41 1 ... I 4 , .. . --�- r' / PERC NO. N/A , ..; INSPECTOR: Barry Lewis (BOH) EVALUATOR: Michael Pimentel, EIT, CSE :/ •• 9' v u•/���,f� `'t�%;�f`�� C.S.E. APPROVAL DATE: Oct. 27, 1999 �, "�%• i • $ • • • f jr .. DATE: January 23, 2024 • ' "" l' -,c }-'-t I TEST PIT #: 1 4 / j f • { $�A ,� �' ELEV TOP = 17.50 `/' /) i ELEV WATER = < 6.50' .!' f-l� PERC RATE _ < 2 min./inch • = ,� " DEPTH OF PER 30 - 48 �F/`J�� �► ,�,j�//�`��,/ TEXTURAL CLASS: " , z' -A LOCUS PLAN SCALE: 1" =1009 NUMBER OF BEDROOMS (EXISTING) 2 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 220 GAUDAY DESIGN FLOW x 200 % = 440 GALIDAY USE EXISTING 1,000 GALLON SEPTIC TANK 1 R 1 B 3 Perc 4 r l� (Y :.• ax INSTALL 2 - 500 GAL. CHAMBERS w/ STONE SIDEWALL CAPACITY (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.74 GPD/S.F.) = GAUDAY (24.0' + 11.83') (2) (T) (0.74 GPD/ S.F.) =106.1 GAUDAY BOTTOM CAPACITY (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY (24.9 x 11.83') (0.74 GPD/S.F.) = 210.1 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 2 TOTAL LEACHING AREA 427.3 SQ.FT. TOTAL LEACHING CAPACITY 316.2 GAL/DAY RESERVED FOR BOARD OF HEALTH USE L0i Fill Loamy Sand 10Yr 5/6 Med. to Coarse Sand I 2.5Y 6/6 No T- 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. t � 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. i 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN i ELEVATION=15.00' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 8. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK LOCATION AND ELEVATION SHOWN ON PLAN. 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 110. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. 16. PROPOSED PROJECT IS LOCATED WITHIN: ASSESSOR'S MAP 45 LOT 7 OWNER OF RECORD: YVETTE GRANT WHILBY CHRISTOPHER WHILBY 17.50' 1 ADDRESS: 168 COMPASS CIRCLE 16.50' 15.00' 13.50' 132' ' 6.50' i No Mottling, Standing or Weeping Observed CENTERVILLE, MA 02632 FEMA FLOOD ZONE X COMMUNITY PANEL# 25001CO567J 17. DEED REFERENCE: BOOK 32220, PAGE 212 18. PLAN REFERENCE: P.B. 264, PG. 94 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 50xO' --50-- 50 50 GAS -1N IN - ' L L Yarmouth Health Department Y OVZD u Na Date REV. DATE U CHURCHILL JR. C/I O L G9 � �'C/''Sn6r �- 0. r,;t%a GIr a ^4Ev CHILL 2. u CI ,, n NO. 1807 2C61 J, Nil 1-:7 e i FEB 2 0 2024 HEALTH DEPT i EXISTING SPOT GRADE EXISTING CONTOUR ! PROPOSED CONTOUR I i PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVER HEAD WIRES EXISTING WATER LINE EXISTING LANDSCAPED AREA TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED H-20 DISTRIBUTION BOX I I PROPOSED 500 GALLON H-20 LEACHING CHAMBER { BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ROBERT B. OUR CO., INC. LOCATED AT ! 4 SOUTH HAWES RUN ROAD YARMOUTH, MA _ ;SCALE: 1 INCH = 20 FT. DATE: FEBRUARY 10, 2024 0 10 20 40 80 FEET + PREPARED BY ij JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By: MCP Designed By: MCP I Checked By: JLC !! JOB No. 7540