Loading...
HomeMy WebLinkAboutBLDSM-24-12 I R E C r 1 v D 1-0:F___,N, SHEET METAL PERMIT FEB 212024 14., ..4AN Commonwealth of Massachusetts YATiACf1EE4F f J TM B U R _D I N v D E PA R T M E N T ,o,,.� Town of Yarmouth Building Department �Y 1146 Route 28, South Yarmouth, MA 02664-4492 Dater a 5 Dee rc,e-ldl R d# • Permit#: fa LS In -3- t-1 — 13- Estimated Job Cost: $ l 5 00, " Permit Fee: $ S 0 .00 (AC- I S C3 Plans Submitted: YES/ NO Plans Reviewed:/ NO Business License# bo'7 (04s loci(9 Application License # 4I3D Business Information Property Owner/Job Location Information Name: 1-ks4-,F,()1- C..,1,15 C: rce, \ s r he Name: Lei--is bc1 gu„lc of c Street: 1 ( , C c, i.-,,,P s i Street: RT a City/Town:L,�,y0, rn Q.L , Thf v (:;')3 City/Town: Ws y cr +rh AL, i'hri Telephone: Sbc `i9 g ` -I V( Telephone: 50% >3'1 b(-,c1 i Photo I.D. required/Copy of Photo I.D. attached: NO Staff Initial: J-1/,;16 unrestricted license J-2/ M-2 restricted to dwellings 3 stories or less and commercial up to 10,000 sq. ft./2 stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft.t"- over 10,000 sq. ft. Number of stories: Sheet metal work to be completed: New work`Renovation: HVAC:_ Metal Watershed Roofing:_ Kitchen Exhaust System:_ Metal Chimney/Vents:_Air Balancing: Provide detailed description of work to be done: )r,s1'-ski Hvc S`-)5-e- i''1S isrc i r ►,a, Dr» 3%0 i40S1, e. S % °/, 0 c ' 14L I(0 s2e.r' 2`"`p m3 ,c, oI ar hFci-+- coo1 c. cpetamc-ss-i- ,nLi INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes No If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy� Other type of indemnity Bond OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner Agent Signature of Owner or Owner's Agent By checking here-->J I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installation performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Inspections shall be called for prior to insulation installation. Duct inspection required prior to insulation installation: Yes No Progress Inspections Date: Comments: Final Inspections Date: Comments: Type of license: By: ''�Master Title: Master-Restricted 1`Signature of Licensee 'I` City/Town: Journeyperson Permit#: Journeyperson-Restricted License Number:` 1 3 ?— Fee: $ Check at www.mass.gov/dpl 'I` Inspector Signature of Permit '1` of Permit Approval DATE(MM/00/YYYY) A � CERTIFICATE OF LIABILITY INSURANCE 02r16r24 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT ' NAME: JIM HINDMAN SCHLEGEL INSURANCE INC,rye-Est): 508-771-8381 `AJCC No); 508-771-0663 West Yarmouth,MA 02673 ADDRESS: schlegelinsurance@gmail.com INSURER(S)AFFORDING COVERAGE NAIL* INSURER A: NGM INSURANCE 14788 INSURED INSURER B: LM INSURANCE COMPANY Nunzio L Jr Napolitano INSURER C: HEATING&COOLING CONCEPTS INSURER D PO BOX 247 YARMOUTH,MA 02673 INSURER E: INSURERF: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADM_SUBH POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER [MMJDDIYYYY) (MMJDDfYYYYJ LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 100,000 DANTAG`E TO RENTED CLAIMS-MADE X OCCUR PREMISES(Ea occurrence) $ 50,000 MED EXP(Any one person} $ 5,000 A MPJ5811A 02/28124 02128/25 PERSONAL&ADM INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER' GENERAL AGGREGATE S 2,000,000 [ JPRO- POLICY � LOC PRODUCTS-COMPIOP AGG $ 2,000,000 OTHER' AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ ....-._� (Err accident) ANY AUTO BODILY INJURY(Per person) $ OWNED -SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) $ UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ S WORKERS COMPENSATION x PERTIJTE 0TH AND EMPLOYERS'LIABILITY Y I N ANY B OFFICER/MEMB RIECUTlVE EXCLUDED? Y N/A WC5315626937012 05/16/23 05/16/24 E.L.EACH ACCIDENT $ 100,000 (Mandatary in NH) E L DISEASE EA EMPLOYEL,$ 100 000 If yP.S,dP,Si:ffiSP.tJhAP.f DESCRIPTION OF OPERATIONS below _E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS)LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if mare space is required) NUNZIO NAPOLITANO HAS ELECTED NOT TO BE COVERED UNDER HIS CURRENT WORKER COMPENSATION POLICY INSURANCE COVERAGE IS LIMITED TO THE TERMS,CONDITIONS,EXCLUSIONS AND OTHER LIMITATIONS AND ENDORSEMENTS OF THE POLICY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN MASS/SAVE ACCORDANCE WITH THE POLICY PROVISIONS, AUTHOR! TATIV i ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD • COMMONWEALTH OF MASSACHUSETTS DIVISION OF OCCUPATIONAL LICENSURE BOARD OF - SHEET METAL WORKERS i ISSUES THE FOLLOWING LICENSE ' MASTER-UNRESTRICTED 1 a z NUNZIO L NAPOLITANO =`-, 76CAMPST y W YARMOUTH,MA 02673-3207 `z J 4132 06/28/2024 240490 ..... .. ... .... LICENSE NUMBER EXPIRATION DATE SERIAL NUMBER MASSACHUSETTS DRIVER'S LICENSE .4' NOT FOR FEDERAL ID fa iss Xc1 NUMBER ' . : '. 0510812019 • NUMBER 808 r , ', •, 12312024 0612311961 S, r.* :--- CUSS +'REST —END ,, � �� ,p NONE NONE NUNZI L ir 1- itti a$ 76 CAMP ST W YARMOUTH,MA 02673-3207 IjA'J /)j -1 EYES HAZ ,q ` 1 DD 05/08/29 1 9Re 02122J2016 06123/6 8 Certification No: NUNZI 76287725 NAPOLITANO has successfully passed a UNIVERSAL -- k' exam on how to responsibly handle TRADE MASTERS refrigerants as required by EPA's o , . , _. National Recycling and Emissions • rr _ Reduction Program Clean Air Act secuon 608 40 CFR Part 82.Subpart F EPA 608 CERTIFICATION (ool (alc Project Name: lewis bay builders Address: 25 Deerfield Road,Yarmouth, MA OUTDOOR DESIGN CONDITIONS Weather station: Chatham Municipal AP Summer Outdoor F: 79 Summer Indoor F: 75 Design Grains: 35 Daily Range: Low Winter Outdoor F: 16 Winter Indoor F: 70 Cooling RH: 50 Elevation(Ft): 62 LOAD CALCULATION TOTALS HVAC System: natural gas high eff. Heated square footage: 1,124 Heating BTUH: 23,911 Cooled square footage: 1,124 Cooling BTUH: 15,320 Heated volume(above grade CF): 10,117 CFM: 589 Cooled volume(above grade CF): 10,117 Sensible cooling: 12,972 Exposed wall area(SF): 1,264 Latent cooling: 2,348 SHR: 0.847 Load Calculation Cooling Heating 0 5,000 10,000 15,000 20,000 25,000 BTUH Approved ACCA MJ8 Calculations Poweiby Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted g; values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. MANUAL J2,; HEATING AND COOLING LOADS HEATING LOADS Heating Loads SECTION AREA HEAT LOSS windows aboveGradeWalls aboveGradeWalls 1,024.3 5,365 22.4% ceilings 1,124.1 1,214 ceilings ducts 0 1,822 infiltration 5.1% floors 1.124.1 6,864 ducts infiltration 0 4.499 infiltration floors skylights 0 0 28.7% windows 240 4,147 Totals 23.911 COOLING LOADS Cooling Loads aboveGradeWalls SECTION AREA SENSIBLE LATENT 15% AEDExcursion 0 259 0 windows appliances -IiiiiiillfaboveGradeWalls 1,024.3 2,295 0 35.8% 7.$°fo ceilings appliances 0 1,200 0 7.2% ceilings 1,124.1 1,102 0 occupants —411114Wtr----ducts ducts 0 518 527 8.4% 6.8% infiltration floors floors 1.124.1 1.260 0 7.1% 8.2% infiltration 0 170 921 occupants 0 690 600 plants 0 0 300 skylights 0 0 0 windows 240 5,477 0 Totals 12.972 2,348 FENESTRATION LOADS Warning (0): This application has glass areas that produced relatively large cooling loads for part of the day. Zoning may be required to overcome spikes in solar load for one or more rooms.A zoned system may be required, or some rooms may require zone control(provided by individual, motorized,thermostatically controlled dampers). Warning (1): The sensible load for this application peaks during late fall or early winter. This behavior is caused by glass that faces SouthEast, South or SouthWest. Some rooms may be noticeably cooler or warmer than the temperature set point if zoning is not provided.Simultaneous heating and cooling may be required. AED Graph (mid-summer) 7,500 5,000 ti co 2,500 0 8 9 10 11 12 13 14 15 16 17 18 19 BTUH — Average Average* 1.3 This graph represents hourly aggregrate fenestration loads in mid-summer. AED graph (fall) 10,000 ti 5,000 CO 8 9 10 11 12 13 14 15 16 17 18 19 BTUH -- Average Average* 1.3 This graph represents hourly aggregrate fenestration loads in October. COMPONENT LOADS ABOVE GRADE WALLS Map trace wall Frame Wall, Wood framing, R-11 cavity Construction nr: 12B-0s w Exposure: NE Heating BTUH: 1,071 U Value: 0.097 Area: 204.5 Cooling BTUH: 458 insulation, Stucco or Siding. Map trace wall Frame Wall, Wood framing, R-11 cavity Construction nr: 12B-Os w Exposure: S Heating BTUH: 1,718 U Value: 0.097 Area: 327.9 Cooling BTUH: 735 insulation, Stucco or Siding. Map trace wall Frame Wall, Wood framing, R-11 cavity Construction nr: 12B-0s w Exposure: SW Heating BTUH: 846 U Value: 0.097 Area: 161.5 Cooling BTUH: 362 insulation. Stucco or Siding. Map trace wall Frame Wall, Wood framing, R-11 cavity Construction nr: 12B-Os w Exposure: NW Heating BTUH: 1,731 U Value: 0.097 Area: 330.4 Cooling BTUH: 740 insulation, Stucco or Siding. BELOW GRADE WALLS There are no components for this section. WINDOWS Default small windows for wall id 6612899 Construction nr: 1G U Value: 0.32 Heating BTUH: 207 Window. NFRC rated, Clear glass. Area: posure: NE SHGC: 0.68 Cooling BTUH: 174 Default large windows for wall id 6612899 Construction nr: 1G U Value: 0.32 Heating BTUH: 622 Area: 36 Window, NFRC rated, Clear glass. Exposure: NE SHGC: 0.68 Cooling BTUH: 547 Default small windows for wall id 6612900 Construction nr: 1G U Value: 0.32 Heating BTUH: 207 Alindow. NFRC rated. Clear glass. Ex osure: S2 SHGC: 0.68 Cooling BTUH: 316 p Default medium windows for wall id 6612900 Construction nr: 1G U Value: 0.32 Heating BTUH: 415 Window. NFRC rated, Clear glass. Area: 24 Exposure: S SHGC: 0.68 Cooling BTUH: 643 Default large windows for wall id 6612900 Construction nr: 1G U Value: 0.32 Heating BTUH: 622 Window, NFRC rated, Clear glass. E posure: s6 SHGC: 0.68 Cooling BTUH: 971 Default small windows for wall id 6612901 Construction nr: 1G U Value: 0.32 Heating BTUH: 104 Window. NFRC rated, Clear glass. Area: 6 Exposure: SW SHGC: 0.68 Cooling BTUH: 191 Default medium windows for wall id 6612901 Construction nr: 1G U Value: 0.32 Heating BTUH: 622 Window, NFRC rated, Clear glass. Exppsure: Sir SHGC: 0.68 Cooling BTUH: 1,177 Default small windows for wall id 6612898 Construction nr: 1G U Value: 0.32 Heating BTUH: 104 Window, NFRC rated, Clear glass. Exposure: niw SHGC: 0.68 Cooling BTUH: 109 Default medium windows for wall id 6612898 Construction nr: 1G U Value: 0.32 Heating BTUH: 622 Area: 36 Window, NFRC rated, Clear glass. Exposure: NW SHGC: 0.68 Cooling BTUH: 672 Default large windows for wall id 6612898 Construction nr: 1G U Value: 0.32 Heating BTUH: 622 Window, NFRC rated, Clear glass. Area: 36 SHGC: 0.68 Cooling BTUH: 677 Exposure: NW Window cooling BTUHs shown here are daily average values.See AED graphs for details of fenestration loads during the day. • CEILINGS Map trace generated ceiling Ceiling under attic or attic knee wall,Asphalt Construction nr: 1613-50 ad Heating BTUH: 1,214 U Value: 0.02 Area: 1,124.1 Cooling BTUH: 1,102 shingles, Dark, R-50. SKYLIGHTS There are no components for this section. Skylight cooling BTUHs shown here are daily average values.See AED graphs for details of fenestration loads during the day. DOORS There are no components for this section, FLOORS Map trace generated floor Floor over enclosed unconditioned crawl space Heating BTUH: 6,864 Construction nr: 19A-Ocp Heating U Value:0.295 Cooling BTUH: 1,260 or basement, no floor insulation, Carpet or Area: 1,124.1 Cooling U Value:0.295 F Value: N/A hardwood. VENTILATION There are no components for this section. HOT WATER PIPING There are no components for this section. DUCTS System generated ducts(below conditioned space) EHLF: 0.082 Heating BTUH: 1,822 Closed Crawl Space-Radial ESGF: 0.042 Sensible BTUH: 518 ELG: 527 Latent BTUH: 527 INFILTRATION NCFM Heating: 76 Heating BTUH: 4,499 Leakage Category: Average NCFM Cooling: 39 Sensible BTUH: 170 Latent BTUH: 921 BLOWER MOTOR There are no components for this section. WINTER HUMIDIFICATION There are no components for this section, OCCUPANTS Nr.Occupants: 3 Sensible BTUH: 690 Latent BTUH: 600 APPLIANCES Small kitchen:1,200 BTUH Quantity: Sensible BTUH: 1,200 Latent BTUH: PLANTS Plant Size: small Quantity: 5 Latent BTUH: 50 Plant Size: medium Quantity: 5 Latent BTUH: 100 Plant Size: large Quantity: 5 Latent BTUH: 150 ROOM DETAIL Room name: whole house Heated square footage: 1,124 Total Cooling BTUH: 11,923 Cooled square footage: 1,124 Total Heating BTUH: 23,911 Heated volume(above grade CF): 10,117 CFM: Cooled volume(above grade CF): 10,117 Exposed wall area(SF): 1,264 Load Calculation Cooling Heating 0 5,000 10,000 15,000 20,000 25,000 BTUH AED Graph(mid-summer) 7,500 = 5,000 ti m 2,500 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH -'-- Average Average* 1.3 AED graph(fall) 10,000 5,000 0 8 9 10 11 12 13 14 15 16 17 18 19 — BTUH — Average Average* 1.3