Loading...
HomeMy WebLinkAboutEngineer Plane LEGEND �--[��--1 PROPOSED CONTOUR � PROPOSED SPOT GRADE --gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —---V PROPOSED WATER SERVICE TEST PIT FIRST FLOOR PARCEL ID. 031 /032 z 5 FT. SOIL REMOVAL SECOND FLOQ-4 PARCEL ID: 031 /031 0 PARCEL U.0 049/025 s 6RO PARCEL ID. 031/27 -�_ Q) C� 1 ±S.F. ' (tom.,, ` V / l f l 1 1 GRAPHIC SC f, all a * � a if LJ,ky tt,r ¢ '''W,,�h a„,,,, � ' i�,�r„ r e --ten., t �'"*,, ,. +•w.,, , �'` e » '" �' y�° 3.3 '� �,r°� �'_, • � 0 `"'w. 'a= s,r g n•*ti. r�°r � '!� '.,w �S°q x .�`"- r .H �e x�W�.,y� p� �P� °S. M F � pf r�'�• e^is. n4'� .'a w'``y °�! �t F P 9 F "N*1 4"y`"P LOCUS INFORMATJOK PARCEL I0: MAP 31 PAR. 026 TITLE REF: 9218/330 PLAN REF: 204/041 PROPERTY IS NOT IN ZONE If PROPERTY IS IN MADEP NIT. SENS AREA FLOOD ZONE: '"X" COMMUNITY PANE. 25001 C--0588--J DATED:07/ 18,% 14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 12 ACADIA ROAD WEST YAR M 0 UTH I .. .11 , a ALICE T. HOGAN ARC 4, 2024 Yannouth A F N#� i 9 'f� 4i= nµ o. 1140 i Department A. 4 k 'STONE MEYER 8c SONS) INC. EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitie5@gmdil.com SHEET 1 OF 2 ELEV. TOP FOUNDATION: (Existing) EL. = 17.21 F. G. EL: 16.0 ENV. 14.21 INV: 13.85 NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE F.G.EL: 15.50 F.G. EL: 14.8 F.G. EL: 14.92 •� fi» a , • ,� ' w • 6 10"i 14° TEE'S ARE TO BE INV. 4" SCH 40 PVC INV. 13.60 GAS " BAFFLE PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK/D-SOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALL COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET &OUTLET TEES AS REQUIRED SOIL LOGS DATE: FEBRUARY 29, 2024 SOIL EVALUATOR: DARREN MEYER, RS, CES 1614 WITNESS: BARRY LEWIS, YARMOUTH HEALTH Elev. 14.28 13.•45 11.36 PERK 0 EL. 9.58 8.28 4.28 TP --1 A LOAMY SAND 1OYR 3/1 B LOAMY SAND 10YR 5/d C 1 F1NE/MEDIUM SAND 2.5Y 6/4 C2 MEDIUM -CoASv SAND 2.5Y 7/3 Depth o~ 10" 35" 72" 120" PERC RATE <2 MiN/1N. ("C" HORIZON) GROUNDWATER OBS 0 110'", EL 5.12 WELL MIW-29, ZONE: 8, LEVEL: 7.74 ADJUST: 2.0 FT, ADJ. GROUNDWATER EL. 7.12 I0 13.20 FINISHED GRADE (14.50) AIN 2% MIN SLOPE OVER LEACHING AREA 4" SCH 40 PVC 2 S= 27 (MIN,) NV. PROPOSED DB-3 DISTRIBUTION BOX (1-120) DaRR.I - 1\10. 11.l0 17 SEPTIC SYSTEM PROFILE * 1, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by kMEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 13.03 INSPECTION PORT TO GRADE INV.= 12.87 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:7.04 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. 6" INSPEMN PORT M WTTOM OF STONE W/IN 6" OF FIN" GRADE (USE PERF. PIPE -- 140 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC INV. ELEV. -12.87 END ELEV.---12.67 3/4' - 1-1/21, D❑UDLE WASHED STONE BOTTOM EL.= 12.17 SEPARATION 5.05 F F. ADJUSTED GRONDWATER EL. 7.12 GENERAL. NOTES.- 1 - ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGININING CONSTRUCTION. 10. EXISTING TANK/LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5 LOCATION WITHIN FOOTPRINT OF PROPOSED NEW SYSTEM. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE ABUTTING WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100" OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 0 1 /8"/FT (UNLESS SPECIFIED) 16. REMOVE ALL UNSUITABLE SOILS 5 FT. AROUND LEACHING TO EL. 11.36 OR TOP OF "Cl" SAND LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. Tops -on- 9" MIN COVER BREAKOUT EL. = 13.20 15 SOIL ABSORPTION SYSTEM (SECTION) T NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS I DESIGN PERC RATE: <2 MIN/IN DAILY FLOW: 440 G.P.D. DESIGN FLOW: 440 G.P.D. GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) SEPTIC TANK/PUMP CHAMBER: 440 gpd x 200% = 880 gpd USE PROPOSED 150OG SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F. DISTRIBUTION BOX: DB-59 H2O (5 OUTLETS (MINIMUM)) PRIMARY S.A.S. USE 401 X 15'W LEACHING FIELD WITH 4 LATERALS BOTTOM AREA: 40 x 15 = 600 SF TOTAL SQUARE FEET PROVIDED = 600 vas. 594.59REQD DESIGN FLOW PROVIDED: 0.74(600 S.F.) = 444 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 12 ACADIA ROADWEST YARMOUTH, MA% Prepared for: Hogan Design and Site Plan by: SCALE DRAWN DATE MEYER&.SONS, INC. N.T.S. DMM 03/04/24 PO BOX 9£31 FAST SANDWICH, 41A 02537 REV DATE CHECKED SHEET NO. 5 0S-362 2922 D M M 2 of 2