HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 80.5'±
FINISHED GRADE
@ FOUNDATION = 79.2'±
PROP. SCH. 40
PVC SEWER
PROPOSED EXTENSION RISER
WITH COVER OVER INLET &
OUTLET TO WITHIN 6" OF F.G.-\ F.G. OVER TANK EL.= 79.31±
21" MIN. ACCESS
COVER (3 TYP.)
2" DROP MIN. I,
_- 3" DROP MAX. 3„ 9
13"
77
14" 76.75'
*77.50' INLET TEE
77.0048 OUTLET TEE
'
TEES TO BE CENTERED GAS BAFFLE
12.9' OFFSET TO FND DIRECTLY UNDER RISERS
6" CRUSHED STONE
OVER MECHANICALLY
COMPACTED BASE M C C
PROPOSED 1,500 GALLON CONCRETE SEPTIC TANK
*CONTRACTOR TO REPLUMB & EXIT FND. LENGTH 10'-6" WIDTH 5'-8" DEPTH 51-8" (Dimensionsper
AT THIS ELEVATION. CONFIR1,11 TOP OF FND. S E P 1 I C TA\I',\ 01 --- I L ri-.--- ACME/Shorey)
EL.=80.5' PRIOR TO STARTING WORK. NOT TO SCALE
9" MIN.
36" MAX.
PROP. SCH. 40
PVC SEWER
MIN S OP
FINISH GRADE OVER D-BOX = 79.3'±
REMOVABLE WATER -TIGHT H-20 COVER
OVER H-20 RISER TO WITHIN 6" OF F.G.
r5" DIA. OUTLET(S)
9" MIN.
36" MAX.
L-52 _
PROVIDE WATERTIGHT
4" PVC IN FROM JOINTS (TYP.)
SEPTIC TANK 0 4" PVC OUT TO
LEACHING FACILITY
76.00' 12" 6"MIN. 75.83'
6" CRUSHED STONE
OVER MECHANICALLY
COMPACTED BASE
5 OUTLET DISTRIBUTION BOX
TO BE INSTALLED ON A LEVEL STABLE
BASE. FIRST TWO FEET OF OUTLET
PIPES TO BE LAID LEVEL.
CROSS SECTION VIEW H- O DISTF)dBUTION BOXDE-TAIL
NOT TO SCALE
U.P.#1013!6
FINISH GRADE OVER CHAMBERS = 79.0' - 79.5'
SLOPE @ 2% MIN. OVER SYSTEM
4" SCHEDULE 40 PVC
MIN SLOPE 1%
1 TOP OF SAS = 76.70'
9" MIN.
75.70' 36" MAX. BREAKOUT EL = 76.20' -�
ODD 0 Cl Cl C�
0
2'
VAR. I 8 5' (TYP) - I
73.70'
PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE
G � ,� C AL i1.I OTES
3/4" TO 1-1/2" DOUBLE WASHED
1.
UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
STONE TO CROWN OF PIPE
METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL
CODE AND ANY APPLICABLE LOCAL RULES.
2" OF 1/8" TO 1/2" DOUBLE WASHED
STONE OR GEOTEXTILE FILTER FABRIC
2.
ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
PLACE RISER ON
3.
4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL
ALL CHAMBERS w/
SYSTEM UNLESS OTHERWISE NOTED.
PIPED INLETS TO
WITHIN 6" ET F.G. ��
4.
TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN
ELEVATION = 76.20' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A
40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF
O • o
THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
5.
SLOPE ALL SOLID PIPE AT 1.0% MINIMUM.
6,
THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
o�
7.
LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK
00
oo
FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS
NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH
AND DESIGN ENGINEER.
V VAR.
VAR
8.
ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK LOCATION AND
VARIES < 68.00'
GROUND WATER ELEV.=
2 - 500 GALLON CHAMBERS 5' MIN
TYPICAL CHAMBER PROFILE B �w20 " FlAki r-DE-AILS
NOT TO SCALE
s Benchmark
�\ Nail Set in U.P.
o\ Elev. = 80.00'
HILLCREST ROAD ' Approx. MSL
(40'WIDE LAYOUT) / /
\ _a /
SLEEVE SEPTIC PIPE � - �\ /
10' EACH SIDE OF �\--7g__--//
WATERLINE CROSSING PROPOSED H-20 PROPOSED TWO (2) 500-GALLON H-20
EDGE OF PAVEMENT DISTRIBUTION BOX LEACHING CHAMBERS w/ STONE
(NOT IN DRIVEWAY)
/ FENCE g - \ 4" 4
_ _ _ 7 PROPOSED SCH. 0
�X� -X-X X-X-X-X-X-�'{x"'��( X- -X-X_ \ ) PVC VENT; EXACT
LOCATION PER OWNER
co 128.00,
PROPOSED 1,500 / � �` (4)-
4 ^ OLD TEL. BOX /
GALLON SEPTIC TANK - x - (2
x 13.1' \ \ o\� 25.0' ' �-(5)
TP 1 x
/ 79x0' o, \ 50 0 / / / 10/
N WALK
17.2'w. 6)
,`9�0 I 20.01`
_ \ STOOP 1(3 t 7
/�
iuf
\ \ HC-1 TOF=80.5'± HC-2 \ \ \ \ �' \\\\\\\ \\ \ 76x4
'A w _ �SC-1
U ' PROP. INV.=77.50' \ f,
SHED
-76--�\ \ �I #41 \ +
a EXISTING
ch 3-BEDROOM
C14 , DWELLING
m �
- 78
REPLUMBING TO
FRONT YARD \ 6-- / / rob
p \ �\// i // 6-
vo DECK - / / 18
to
\Ile
\
/
/ a)
MAP 151 ,€ / , 6a, o
LOT 70 co
MAP 151
s � .- ' / / LOT 68
A,
Ln `�6g�
L ISTING 1,(:::I0 G ALLOh; SEPTIC T,^_"; . 6g-
TO C.G s ..: ,N:JOi'dI='J !1E\ J 0 C:'., l 1.7.v.14
(i.C. PL'%'1--1E D, 13CTT0".1 O`s-' _" D /� /
RUPTURED AND I=ILLFD vI/ CLEAN A',NfD)
PIT TO 3E PU",I D,
FILLED,',," CLEA; I
S: �! D 9 � 9 A N D 0l"IED
NOTES:
1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF
EACH SEPTIC SYSTEM COMPONENT.
2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT
DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF
HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA.
3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II.
4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY
FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS
IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL
NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT.
MAP 151
LOT 69
20,406± S.F.
SITE PLAN
SCALE: 1" = 10'
SWING -TIES
DESCRIPTION
HC-1
HC-2
SC-1
TANK COVER IN (1)
17.8'
30.2'
--
TANK COVER OUT (2)
22.7'
23.7'
-
CORNER OF STONE (3)
--
15.1'
21.0'
CORNER OF STONE (4)
-
23.2'
27.0'
CORNER OF STONE (5)
--
43.2'
18.3'
CORNER OF STONE (6)
--
40.1'
9.8'
CORNER OF STONE (7)
--
34.5'
4.9'
LOCUS PLAN
SCALE: 1" = 1000'
DESIGN DATA
NUMBER OF BEDROOMS (EXISTING) 3
NUMBER OF BEDROOMS (DESIGN) 3
DESIGN FLOW 110 GAUDAY/BEDROOM
TOTAL DESIGN FLOW 330 GAUDAY
DESIGN FLOW x 200 = 660 GAUDAY
USE PROPOSED 1,500 GALLON SEPTIC TANK
4.83
(TYP.)
ELEVATION SHOWN ON PLAN.
9.
CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
VARIES
THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT
CHAMBER END VIEW
1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES
TO THE DESIGN ENGINEER.
10.
ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT.
11.
NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING
IS TO OBTAIN SUCH DETERMINATION FROM
I- � � DATA ��
APPROPRO TE AOUTHORITY.PLICANT
l r:'
PERC NO. N/A
12.
ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED
INSPECTOR: Jay Gardiner (BOH)
UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR
/
EVALUATOR: Michael Pimentel, EIT, CSE
TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING.
�'�
C.S.E. APPROVAL DATE: Oct. 27, 1999
13.
DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES.
DATE: May 12, 2022
14.
WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE
TEST PIT #: 1
MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY.
REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
ELEV TOP = 79.00'
FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
ELEV WATER = < 68.00'
15.
CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN
SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK.
PERC RATE _ < 2 min./inch
16.
PROPOSED PROJECT IS LOCATED WITHIN:
m
DEPTH OF PERC = 18" - 36"
ASSESSOR'S MAP 151 LOT 69
TEXTURAL CLASS: I
OWNER OF RECORD: ELIZABETH TEUWEN, TRUSTEE
ADDRESS: 418 CIRCLE AVENUE
` �•
0" 79 00'
TAKOMA PARK, MD 20912
V
611
�7
B
Vr
18,E
\-
Perc
I
36"
J j `-
:r
J�5
INSTALL 2 - 500 GAL. CHAMBERS w/ STONE
SIDEWALL CAPACITY
(TOTAL PERIMETER) (2' HIGH) (0.74 GPD/S.F.) = GAUDAY
(73.1') (2') (0.74 GPD/ S.F.) = 108.2 GAUDAY
BOTTOM CAPACITY
(FOOTPRINTAREA) (0.74 GPD/S.F.) = GAUDAY
(311.1 S.F.) (0.74 GPD/S.F.) = 230.2 GAUDAY
TOTAL NUMBER OF CHAMBERS 2
TOTAL LEACHING AREA 457.3 SQ.FT.
TOTAL LEACHING CAPACITY 338.4 GAL./DAY
RESERVED FOR BOARD OF HEALTH USE
FEMA FLOOD ZONE X
78.50' COMMUNITY PANEL # 25001CO577J
17. DEED REFERENCE: BOOK 32259, PAGE 102
18. PLAN REFERENCE: PLAN BOOK 203, PAGE 111
77.50'
19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
76.00' 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY
FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE.
21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
22. IN ACCORDANCE WITH 310 CMR 16.401-15.405, THE FOLLOWING LOCAL UPGRADE
APPROVAL IS REQUESTED FROM CMR 310 CMR 15.211:
1.) A 4.9' WAIVER (20.0' - 15.1') FOR THE SETBACK FROM SAS TO THE HOUSE FOUNDATION.
132" ' ' 68.00'
No Mottling, Standing or Weeping Observed
N
50xO'
--- 50 ---
50
50
GAS
O/H/W
-W W-
Health Depart>s�tgnt O O O
1)
Daft
13
EXISTING SPOT GRADE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED SPOT GRADE
EXISTING GAS LINE RECEIVED
EXISTING OVER HEAD WIRES MAN 0 g 2024
EXISTING WATER LINE HEALTH DEPT
TEST PIT LOCATION
PROPOSED 1,500 GALLON SEPTIC TANK
PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
PROPOSED H-20 DISTRIBUTION BOX
PROPOSED 500 GALLON H-20 LEACHING CHAMBER
REV. DATE_j BY I APP'D. DESCRIPTION
PROPOSED SEPTIC SYSTEM UPGRADE
SN [SF MgSS.10. PREPARED FOR
JOHN L. `^�, ROBERT B. OUR CO., INC.
o CHURCHILL JR.
C L
NO 48066
LOCATED AT
41 HILLCREST ROAD
YARMOUTH PORT, MA 02675
SCALE: 1 INCH = 10 FT. DATE: MAY 27, 2022
0 5 10 20 40 FEET
OF
JOHN L. tiG�� PREPARED BY
o CHURCHILL JR.
CIVIL ; JC ENGINEERING, INC.
NO. 41807 2854 CRANBERRY HIGHWAY
jvIST R: EAST WAREHAM, MA 02538
508.273.0377
Drawn By: MCP Designed By: MCP I Checked By: JLC JOB No. 6269