Loading...
HomeMy WebLinkAboutApproved Engineer PlansWF 5.86 � I WETLANDS II m I V / N .redge of Welland a WF WF WF j 6.51 6.93 13.12 4 EXISTING CESSPOOL TO BE FILLED KITH SAND & ABANDONED BENCHMARK CORNER BULKHEAD EL=19.15 — —98 — — EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE W EXISTING WATER SVC. -- EXISTING GAS SERVICE —O.H. < = OVERHEAD WIRES TEST PIT BENCHMARK LEGEND PK SET IS.d6 I p,OAD 14.55F l� 13.67 P°`rement / ..�" e x 1 71 ed9 13.21 o f —i* 15,98 -- x 15.14 S g1*3o'00 85.00' 14.35 /Y", / LOT 9 } ��11 9,350±S.+ 18.26,F.. !✓ .81 tj ' .r► "i / y J j 100 �� o 7018.51 .y u ER -ff64 9 0 o . .PAVED DRIVEWAY R CL-9 ED MAR 0 8 2024 HEALTH DEPT. 0 A.,-18.01 OWNER OF RECORD PERREAULT, JULIA L (LIFE EST) 19 BEACHSIDE DRIVE LUDLOW, MA 01056 8.40 1 EXISIINU HOUSE(#9) T.O.F.=19.5-4 PATIO 18.48 x 18.49 t CD 0 0 0 0 `-EX. SEWER 5 INV =16.6t (PLUG) LOCUS MAP NOT TO SCALE EXISTING CESSPOOL TO BE FILLED WITH SAND & ABANDONED 0 PROPOSED SEPTIC TANK T Z., — ,- 19 241. 18.950 1 1 VL19.21 �?-;9.1 19.34 14 g130'00 E ' 19.26 CBDH PROPOSED S.A.S. 2-5CO GALLON CHAMBERS SURROUNDED Wf4' STONE MAP ID: 29-15 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 9 FIRST ROAD, WEST YARMOUTH, MA Prepared for: Edward Perreault, 19 Beachside Drive, Ludlow, MA 01058 Engineering by. Surveying by: SCALE DRAWN JOB, NO. Engineering Works, Inc. Richard J. Hood PL5 1 `=20' P.T.M. 272-23 12 West Crossfield Road 12 Settlers Path DATE CHECKED SHEET N0. Forestdale, MA 02644 Sandwich, MA 02563 (508) 477-5313 (508) 246-6260 1/24/24 P.T.M. 1 of 2 PROPOSED SEPTIC TANK PROPOSED D-BOX PROVIDE RISERS WITH COVERS OVER INLET Et OUTLET MANHOLES SET TO 6" OG FINISH GRADE. INSTALL RISER & COVER SET TO 6" OF GRADE -T.O.F=19.5* /-F.G. EL-18.6t F.G. EL=19.0f F.G. EL=19.2t L= 13' L= 10' 0 S=1% (MIN.) L = 5' 4"SCH40 PVC _ S=1% (MIN.) 0 S-1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC INV.- 1 S4' 16.00 Or LJOUID - LEVEL BDOAS BAFFLE 1 PROPOSED SEPTIC TANK MODIFY INTERIOR PLUMBING FOR ONE SEWER OUTLET AT, OR ABOVE. INV.=16.2 INV.=15.60-J PROPOSED V.=15.75 D-B 3 OUTLETS H-20 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. 2) SEPTIC TANK & D-BOX SHALL BE SET LEVEL AND TRUE EO GRADE ON A MECHANICALLY COMPACTED STABLE BASE OR SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310 CMR 15.221(2), 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITS. ZABEL OR EQUAL. 2' EFF. DEPTH INV.=15.43 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL. 15.7 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT F.G. EL=19.2t MAINTAIN 2%d SLOPE OVER SA.S. r-2" LAYER OF 1/8" To 1/2" DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) :YsW: ?vim.'•:=i.•4.'• :%7r-,TO 1-1/2- DOUBLE WASHED STONE INV.=15.20 500_ GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN H-20 RATED TOP CONC. ELEV.= 16.3f BREAKOUT ELEV.= 15.70 INV. ELEV.= 15.20 BOTTOM ELEV.= 13.20- 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' (MIN.) ABOVE G.W. BOTTOM OF TEST PIT, EL=7.7 4' 1 2 x 8.5' = 17.0' 1 4' EFFECTIVE LENGTH = 25.0' SEPTIC SYSTEM PROFILE GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. S. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SAS. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. LEACHING SYSTEM SECTION /EXISTING, HOUSE(#9) T.O.F.=19.5f 6q; WA zji 1RSe f1 PROPOSED S.A.S. 2-500 GALLON CHAMBERS 7' SURROUNDED W/4' STONE r 0 S.A.S. LAYOUT SOIL LOG DATE: JANUARY 4, 2024 SOIL EVALUATOR: ANNA WIMMER, SE-14615 WITNESS: BARRY LEWIS HEALTH AGENT ELEV. TP- 1 DEPTH ELEy. TP-2 DEPTH 19.2 0" A SANDY LOAM 10YR 3/3 t 9.2 0" A SANDY LOAM 10YR 3/3 18.6 7" B B DESIGN CRITERIA LIOYRR /6"° Low /6D 17.2 �. 24" 17.2 f, 24" NUMBER OF BEDROOMS: 3 SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY PROPOSED D-BOX: 1 INLET, 1 OUTLET (MINIMUM), H-20 RATED USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SiDEWALL AREA: 2(12.8' + 25.0') x 2 = 151.2 S.F. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. TOTAL AREA: ........... .................................................. 471.2 S.F. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.6 GPD SANDY LOAM ! SANDY LOAM 2.5Y 6/4 ! 2.5Y 6/4 7.71 1 138" 7.7 1 1138" NO GROUNDWATER ENCOUNTERED PERC RATE: <2 MIN./IN. "C" HORIZON PROPOSED SEPTIC SYSTEM UPGRADE PLAN 9 FIRST ROAD, WEST YARMOUTH, MA Prepared for. Edward Perreault, 19 Beachside Drive, Ludlow, MA 01058 Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineering Works, Inc. Pichard J. Hood PUS N•T,S P.T.M. 272-23 12 West Crossfield Rood 12 Settlers Path DATE CHECKED SHEET N0. Forestdole, MA 02644 Sandwich, MA 02563 (508) 477-5313 (508) 246-6260 1/24/24 P.T.M. 2 Of 2