HomeMy WebLinkAboutEngineer PlanNOTES LEGEN D C/Aialll'W 1-V141VV1\ X 99 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 1g8.41 PROPOSED SPOT EL. TH1 -0 TEST HOLE 22'7�, SLOPE OF GROUND UTILITY POLE Y FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAVIING *NOTE: INTERIOR PLUMBING TO BE RAISED -TO ELEVATION SHOWN ON PLAN VIEW. PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY PORTION OF THE SEPTIC SYSTEM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-20 SEPTIC TANK & A 1000 GAL. H-20 PUMP CHAMBER LEACHING: 330 GPD (.74) = 446 SF REQUIRED 8' X 56' = 448 SF OK 448 SF X .74 = 331 GPD OK USE A 8' X 56' PRESSURE DOSED LEACHING FIELD ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION CAST IRON COVERS TO FIN. GRADE 6.0' MINIMUM 75'1OF COVER OVER PRECAST PRECAST H-20 RISERS (TYP.) 2'0 INV. IN 3.7' - FLOAT SWITCH SETTINGS: *4.35'� 10" 1500 GAL H-20 14" ALARM ON 3.97' TEE SEPTIC TANK TEE 3.72' PUMP ON 4" WORKING RANGE 4' LIQ. LEVEL ZABEL FILTER (ACME OR EQUAL 4' LIQ. LEVEL (ACME OR EQUAL) )`: OUTLET TEE PUMP OFF , .,...«•;; • ..,, .. ;: . , 00o W/EXTENSION 0 0 0 D O 0 0 O- 0 0 0 0 0 010 0 0 0 0 0 0 O�•t .°o°000°0000000°000°000°o°0000000000000000000° 0000 000�o00n1?n000o0o0o000c`O^OOO�O,OoO0000, 4 6" CRUSHED STONE OR MECHANICAL -_ COMPACTION. (15.221 (21) { 2 % SLOPE) MIN. (1 % SLOPE) FOUNDATION - 19' SEPTIC TANK 0, f FEMALE ADAPTOR & THREADED SCH 40 PVC PLUG 2"0 SCH40 PVC MANIFOLD (TYP. BOTH ENDS) --'�' PITCH MIN- 1 I r ----- N ---------------- -�-- I 11 2.50' !I o I w I rn 1 I � UJI I 1 J �t � 0 I � � I LEACHING FIELD w 1 U U a I 1 o I I (n I 1 N I 1 U CONNECT ENDS FEMALE ADAPTOR & THREADED PLUG SCH 40 PVC PLAN VIEW PIPING DETAIL 27* MIN. SLOPE OVER SYSTEM 4" LOAM & SEED Setback = 1 %" (41 mm) (5' batter angle on wall) +�- - 9" COVER ASJ 5'MIN. °1 J- 00 12" PEASTONE x COARSE SAND BACKFILL AGAINST WALL D 40 MIL LINER FROM TOP PEASTONE/WALL"'�_ rrnn TO 12" BELOW GRADE N REDI-ROCK OR EQUAL RETAINING WALL UNITS MOVE BLOCKS FORWARD DURING �; INSTALLATION TO ENGAGE SHEAR KNOBS •:4 .:. 6"X30" Crushed Rock or �' Z Unreinforced Concrete FILL WEDGE BETWEEN Leveling Pad req. ADJACENT BLOCKS WITH DRAINSTONE RETAINING WALL CROSS SECTI 1 NOT TO SCALE 20 I j 15 w Lk- z w 10 z J 0 5 0 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP IDICE ##23-222 ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP LL WIRING TO CODE. 6.0' PROVIDE INSPECTION PORT TO GRADE 4" SCH40 PERFORATED PVC DOWN TO SYSTEM PROFILE SAND AT BOTTOM LEACHING FIELD, - - 4 THRE DED COVER AND 1000 GAL. H-20 PC U 2" PRESSURE LINE 1 330 GAL.+ SLOPE TO DRAIN BACK RESERVE 0.25" WEEP HOLE CHECK VALVE 3" MYERS SRM 4 _ 4" SUBMERSIBLE 4/10 HP 18" SYSTEM (OR EQUAL) PUMP BUOYANCY CALCS: H-20 1500 GAL. FAST ST WEIGHS 27,500 LBS 4.21 x 11.0 x 6.0 X 62.4 = 17,338 LBS UP (OK) H-20 1000 GAL. PC WEIGHS 17,250 LBS 4.48 x 9.0 x 5.25 X 62.4 = 13,208 LBS UP (OK) BEDROOM PUMP PIT LI1/lNG ROOM FAMILY ROOM BA TH DINING BEDROOM KITCHEN ROOM BATH / EXISTING IST FLOOR PLAN Q BEDROOM DEN EXISTING 2ND FLOOR PLAN (3) LATERALS 2.5' CENTER TO CENTER SEE LAYOUT DETAIL MIRAFI 140N FABRIC OVER STONE tzEL. 9.01' 0000 00 0 000000000a000000p000000000000a.,0000 ° °° 0000 1 2q INV. EL. 8.93' 8" °pOpOoOor, O{}o0o0oODOQOo°�Oo0o0o00000o0o°�O�0 0, 0o0 0 ° OQ°� 0000000 O°tl00000000000000000000000000000000000:°0000000000000 0000 q °000°°o°oo°o o°o°0000°o°oo°0000°oo°oo°oo°0000°oo°oo°oo°°0000°0000°oo;°oo°0000000000000 000 6 EL. 8.43' O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 °o°o°° °oo°°°o° °?0000...°oo°°oo°°°000°°°°°°°o,°o°o°o o° 2.0"OSCH40 PVC 8" TOTAL OF .75" - 1.5" STONE ORIFICE SHIELD OS200 WITH 1/4" ORIFICES DOUBLE WASHED ONLY ORENCO SYSTEMS INC DRILLED AT 4' O.C. PH. 1-800-343-9843 ALTERNATING UP AND DOWN CLEAN COMPACTED COARSE SAND FILL OR EQUAL SEE DETAIL DRILL DISTAL END ON TOP. UNDERNEATH LEACHING FIELD LEACHING FIELD SECTION NOT TO SCALE (NOT TO SCALE) INV. 8.93' 94' PROVIDE 160' OF 40 MIL LINER AT 5' OFF SAS IN AREA SHOWN. TOP AT ELEV. 4 Q'-• BOTTOM AT EL 4.0'f FA 1/4"0 HOLE AT 4' O.C. PROVIDE A LEBARON LA910 CAST IRON ACCESS 4" VENT, PERF. PORT H-20 CONSTRUCTION. RUNS OVER 2" PROVIDE CHARCOAL FILTER DRILL LAST HOLE IN EACH AND INSECT SCREEN LATERAL ON TOP TO VENT AIR WHILE LATERAL FILLS FEMALE ADAPTOR & THREADED PLUG 2"0 THREADED END CONNECTION g 76' SCH 40 PVC 1/4" SHIELDED g 01, ORIFICES _-_ MARK W/ REBAR 00 0 00 0000 009 000 00 �_0$_ 0 , 2" INVERTS of LEVEL AT 8.93' - _ - - _00._ _ _�, BOTTOM LEACHINAT EL. 8.43' -_-� 5.0' , \LEVEL 2" END MANIFOLD PITCH TO DRAIN BACK TO PUMP CHAMBER- NO LOW SP o Iri 3/4" TO 1 1/2" DOUBLE WASHED STONE SIDE ELEVATION VIEW 117 ADJ. G.W. EL= 3.43' - LEACHING FACILITY ALTERNATE BETWEEN TOP & BOTTOM OF PIPE. EXACT DIAMETER HOLES SHOULD BE SHOP DRILLED WITH A DRILL PRESS TO ENSURE UNIFORMITY. REMOVE BURRS PRIOR TO PLACING PIPE. J `4 2.0" 0 SCH-40 PVC LATERAL SNAP -ON SHIELD DRAINAGE SLOTS 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 40 MIL LINER 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-2Q SEE WALL DETAIL 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) TOP OF WALL EL. 9.6 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO a, BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. > 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. D X 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING N DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1 J) REDUCTION OF THE REQUIREMENT OF A 12 INCH SEPARATION BETWEEN THE INLET AND OUTLET TEES AND HIGH GROUNDWATER. (1" REQUESTED, BOOTS PROVIDED) TENNIS COURTS 1 l ) - -A.," L ' 4,3 _7� �E RE-ROUTED / REQ. / 7 1 kPB UT -01 GRAVEL RIVE \ �OF UNSUITABLE SOIL, /REQUIRI �L ;ERIMETER OF LEACHING FACILI , 'SUITABLE SOIL L¢YtR. REP E �N MED. SAND MEET TIONS OFr„� CMR 15.255(3) ANY UNSUITABLE BE LOCUS MAP REMOVED11. BENEATH AND 5'RIAL AROUNDOUNTERED THE PROPOSEDL LEACHING FACILITY. SCALE 1 "=2000't 12. EXISTING SEPTIC SYSTEM SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. ASSESSORS MAP 14 PARCEL 102.1 13. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 11) FOR ZABEL FILTER. INSTALLER MUST FOLLOW AS SHOWN ON COMMUNITY PANEL 25001C0588J MANUFACTURER'S SEPCIFICATIONS FOR PROPER FILTER INSTALLATION. DATED 7/16/2014 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS LOCUS IS PARTIALLY LOCATED WITHIN THE STATE SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT NITROGEN SENSITIVE AREA REQUIRED. 15, OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE ZONING SUMMARY FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. ZONING DISTRICT: R-25 DISTRICT 16. WETLAND FLAGGED BY PAUL SHEA OF INDEPENDANT ENVIRONMENTAL CONSULTANTS. MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30, MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% MAX. BUILDING HEIGHT 35' TEST HOLE LOGS Yarmouth Conservation Conditions: 1. A hard copy of the plan shall be provided to the Conservation Administrator for review. An electronic copy of the final plan shall DANIEL E. GONSALVES, SE #13587 be provided to kgrant@yarmouth.ma.us. ENGINEER: 2. The proposed sewage disposal system shall meet the applicable BARRY LEWIS Title 5 wetlands setbacks as set forth by the Health Department. WITNESS: 3. A'work limit' line shall be established with Erosion Controls (i.e 10/5/2023 straw bales, staked filter fabric, bark mulch, "silt sacks," products approved by DATE•• made with rice straw, and other weed -free products or the Commission.) Hay bales are not allowed. It is the applicant's PERC. RATE _ < 2 MIN/INCH responsibility to implement and maintain appropriate and adequate erosion controls measures throughout the construction process. I 4. No work of any kind shall occur on the Resource Area side of the CLASS SOILS work limit line. This line shall be established prior to any construction or work. 5. All imported fill shall be clean and not contain any foreign debris such as cement, bituminous concrete, rubber, metal, trash, ELEV. ELEV. boulders, etc. 17 2 S. Debris, including litter, shall be picked up immediately. Any excess 0„ 4.0' 0" 4.0' material that is excavoted f:om the job s!_e c Tall be disposed of at a location approved by the Conservation Administrator or in a covered dumpster, No debris shall be allowed in a Wetland or A A Waterway. LS LS 7. Washing of equipment/tools shall be done OFF -SITE or handled in 1 OYR 4/2 1 OYR 4/2 a manner approved by the Conservation Administrator. 18" 12" 8. No equipment shall be refueled, nor shall fuel be stored within 100 feet of a resource area. 9. The cesspool is to be pumped dry, the connection broken, and B B filled with clean sand. LS LS 10. Any area that is disturbed during construction shall be revegetated 1 OYR 4/4 1 OYR 4/4 immediately or as soon after as the growing season commences. Permanent stabilization shall be carried out in order to minimize erosion. 24" 2•0 26" 1.8' C C SIEVE MS MS 2.5Y 6/6 2.5Y 6/6 84'> " -3.0 I I ' -3.0 84 GROUNDWATER ENCOUNTERED AT 32" EL. 1.33 G-W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 2.1' OCTOBER 2023 �\ L INVERT PIPE TO MAIN AIN PROPER TANKS MA COVER PREPARED FOR OffA?' V�► MICHPL K"'ICHEVSKY ORIFICE SHIELD OS200 ;%' �'��,�F 0 qc-t-��y�� .. o DAjN!IEL G " r ' &ALA y g P s ka'I ORENCO SYSTEMS INC p A.1� CI`•'1L DATE: JANUARY 12, 2024 PH. 1-800--348-9843 OJ%t.A U i4 No. 46502 NO. 40080 � OR EQUAL. �0 ,� L °� �,S, Ear ;;;% i Scale: 1 = 20 D ; _ ,. 0 10 20 30 40 50 FEET off 508-362-4541 f��!IE;_ �\ 4_0 DANi RECEIVED fax 508-362-9880 0 J Al. 1 downco e.com r I .LA 0 @:, c) c., ._ k MAR 0 2024 -. 0 ='.6�t)2 Q_ a0®% Capa 1�%��/`%COMA?. 14C. civil engineers DEPT. V Ion d surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 NHO DATE DANIEL A. OJALA, P.E. SURVEY: DEG .LS' DRAFTED BY: D�,E�G•' CHECKED BY: �•�-' 23-222