Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. ;`-l' Lot 2(12 . 2- Zone of Contribution: In Out )( Acreage 25,8573-`SF Commercial: Residential: t' Street: 18( R-c ✓a v 5z- o Village: S -rr4 Floor Plan: V #Bedrooms: , b '4r1 re., Owner: C/ L i48 - -- Installer: Address: Phone: Phone: Builder: 4-6'k)1. V - Engineer: .-ZZ.e)•v v C-A..P E Address: Phone: Phone: N/A YES NO 1. Required#of copies received X 2.Date of soils exam and percolation test not older than 2 years f 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: 7 6.Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation,deck Var.: p i rs o,v S4-A-6. t/ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V 9.Leaching minimum 100 ft from wetlands Var.: 7 10.Leaching minimum 150 ft from drinking we11125 ft irrigation well Var.: / 11.Tank/leaching minimum 10 ft from property line Var.: ✓ 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: _ i/ 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: ./ 15. System not in top or subsoil(A,B horizons)or 5'removal / 16.Proposed contours are suitable J / 17. System meets slope requirements-min. 1/8", %"preferred %/ 18. System meets breakout requirements PVC liner: Wall: I 19. Specified tee sizes are proper, gas baffle on outlet tee V 20. Sewage is under 10,000 gpd for parcel i 21.No garbage disposal I 22. System adequately sized for its intended use ✓ 23.Minimum 6"stone or compacted below tank and dbox k' ". . 24. Manhole covers within 6"of grade,pump chamber cover to grade ✓ 25. Inspection port on plastic chambers/leach field V 26. Electrical permit for pump chamber/Separate meter for duplexes ✓ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size / 28. Septic tank/pump chamber to be factory waterproofed gray D ,' ;-n,-- 29.Vent provided if leaching below 3 feet,under driveway/parking / 30.Buoyancy calculations for tank/pump chamber / _ 31. Engineer to inspect and certify soils: wall: commercial: _ ,/ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature _ _ / 33.H-20 loading is subject to vehicular traffic, groundwater _ / 34.Title V Application and permit fee,installer signature %/ 35.Foundation footing min. 2 feet above adjusted ground water for new house / 36.Deed Restriction required max. #bedrooms: max.flow: gpd / 37. Check area lots for groundwater/Label groundwater in Assessor's Map ` / PIan reviewed by: �� 2737-1&& `4f _ Ji/'t3/45 7-2- 6 03 03