Loading...
HomeMy WebLinkAboutEngineer Plan(VOTES LEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND cob UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TOP FOUND. EL., 32.3' PRECAST H-10 RISERS (TYP.) .• 20 PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE MINIMUM _ 35.3'11 11 PRECAST (•IP.j° 18" EXISTING 24" TEE 2500 GAL TEE 33.8t'* 33,79' SEPTIC TANK** -- GAS BAFFLE "INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 10 w 14 PROPOSED w TEE 1500 GAL H-10 TEE SEPTIC TANK GAS BAF 4' LIO. LEVEL (ACME OR EQL SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE MIN. 2" WALL THICKNESS MIN. 2" WALL THICKNESS BLOCKS OR OUTLETS TO " " PRECAST RISERS DBOX #3 & #4 4 OSCH40 PVC 4 0SCH40 PVC MORTAR ALL L � PIPES LEVEL 1ST 2 PIPES LEVEL 1ST 2 COMPONENTS H-10 EL 30,17' ENDS HS16ES �0000"oy°o 4 \3 ° ®®®L� ®®®® PJ ® -®®®® ;ooag0000' 3 4 000 °°,0000 , o 0 0 0 0 0 °O°O°O°O .®®® ®®®®®®® ®®®®®®®® )°O°°°O °so.'�o�o^go 30.42 °so�ogopo o r a o°g°°° ° ° ° �1®Cl��®���®�®����®C� pr®�a�(®�®L�®' L� `®gip®® ° 00000 33.53' 33.36' 30.25' '°0000000 °°°°°°° °°°°°°° 'o 6" MIN. SUMP 6" MIN. SUMP } ;000° 12" MIN. INT. DIM. 12" MIN. INT. DIM. 1 LH-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL 3/4"-1-1/2" DOUBLE WASHED STONE (3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL nvrQei i nrkAI-NcinNc Tn nUTSIDE OF STONE• 33' X 11), RV LEACHING FACILITY 'STEM DESIGN. 23.0' BOTTOM TH-2 _L NO GROUNDWATER FOUND AGE DISPOSER IS NOT ALLOWED 1NG 9 BEDROOM INN ,OSED 3 BEDROOM EXPANSION aN FLOW: 12 BEDROOMS 0 110 GPD = 1320 GPD C TANK: 1320 GPD (2) = 2640 GPD (1) = 1320 + 618 = 3960 GAL. REQUIRED XISTING 2500 GAL. SEPTIC TANK & ADD )0 GAL. SEPTIC TANK IN SERIES (4000 GAL. TOTAL) ING 9-BEDROOM LEACHING FIELD TO REMAIN -ZING EXPANSION DESIGN FLOW: )ROOMS ® 110 GPD = 330 GPD -ZING: : 2 (33.5 + 12.8) 2 (.74) = 137 GPD )M 33.5 x 12.8 (.74) = 317 GPD 614 S.F. 454 GPD ;3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) 4' STONE ALL AROUND MA OVED DATE BOARD OF HEALTH Yarn `.', _ _t tb Department Na Date �����V•i QI= h+,d�gs�� �� �DANIEL yri" 11 A. F' ! QFFSS�� 1. DATUM IS NAW 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-],Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. D' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER 17' PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL REMAIN. 13. WETLAND FLAGGED BY BRAD HALL OF BLH ENVIRONMENTAL CONSULTING 1-31-24. 14. MATCH ALL EXISTING GRADES INTO EXISTING LEACHING FIELDS. INSTALLER TO CONFIRM INVERT ELEVA11ONS PRIOR TO INSTALLING ANY PORTION OF THE SEPTIC SYSTEM EXPANSION. 0 a� 0 n Tho Road � Z moo' o O Qc i o Sondysid ��� Loc us 0 Dennis Pond c 0 a 0 LOCUS MAP SCALE 1 "=2000't ASSESSORS MAP 122 PARCEL 93 SITE IS NOT LOCATED IN MASSDEP NITROGEN SENSITIVE AREA (NSA) TEST !-SOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: BARRY LEWIS DATE: 2/16/2024 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS ELEV. ELEV. p" 35.0' p" 34.0' A A SL 4" 1OYR 3/2 1OYR 3/2 B 12„ `SL 24" 10YR 5/4 B 33.0' SL 1OYR 5/4 �G 36" ///// 31.0' 60" 10YR 7/4 / 30.0' ® UNSUITABLE SOIL C C2 1 /FLS M/CS 96" 2.5Y 5/3 27.0' 2.5Y 7/4 C3 VFS 2.5Y 7/2 DANIELA. o O..IALA CINAL No.46502 AL DATE DANIEL A. OJALA, P.E., P.L.S. 144" I 123.0' 132" 1 123.0' NO GROUNDWATER ENCOUNTERED I ....Em If:,..TIE'Ro IE'Ro PLA OF DATE: MARCH 8, 2024 n2ZZ_ Z 0 y I ED Scale: 1 "= 20' MAR 2 U 2024 0 10 20 30 40 50 FEET HEALTH DEPT. off 508-362-4541 fax 508-362-9880 downcope.com O ®tyll clape Ie ifteer'fr , ulc. civil engineers Ion d surveyors 939 Main Street ( Rte 6A) SURVEY: NHO YARMOUTHPORT MA 02675 DRAFTED BY: DEG CHECKED BY: 24-018 INN AT CAPE COD.DWG