HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH 6, SEWAGE PLAN REVIEW CHECKLIST Location: AM ' =5 LOT 0/U//Ci 1 Date of Subdivision Approval Street / Ciitl Zone of Contribution: In Out Village 5-, Commercial Residential ,/ Owner: WO/VS 47 ;1L-TT Installer z .z_T Builder: Engineer //G€7Z -/.6 d- 7� 6'-: . 77 N/A YES NO 1. Required number of copies received. = ' 2. Date of soils exam and percolation test not older than 2 years. f 3. 4 feet of naturally occurring pervious material, above water table(new construction) 4. Foundation 2 feet above high point of fronting road for new construction. 5. Water availability letter from Water Department for new construction. ,--- 6. Benchmark indicated and shown - NGVD if near wetlands. t./ 7. Building sewer does not exit center of house. 8. Septic tank a minimum of 10 feet from house and deck. 9. Leaching a minimum of 20 feet from house and 10 feet from deck. 10. Leaching a minimum of 100 feet from wetlands. 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. 12. System meets all other setback requirements. 13. Uses adjustment for maximum high groundwater. 14. Leaching 4 -5 feet above adjusted water table or bottom of test pit. 15. System not in top or subsoil or 5 foot removal. 1� 16. Proposed contours are suitable. 17. System meets slope requirements - min. 1/8", 1/4" preferred. i . 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. 19. Specified tee sizes are proper, gas baffle on outlet tee. 20. Sewage flow under 10.000_gpd for parcel. „/ 21. No garbage disposal. ,/ 22. System adequately sized for its intended use. ,/ 23. Minimum 6" stone or mechanically compacted below the tank and d-box. 24. Manhole covers within 6" of grade - septic tank and pump chamber. 25. Electrical permit for pump chamber. •✓/ 26. Pump system - 2" line, weep hole. check valve, sanitary in d-box, alarm on separate circuit. 27. Septic tank and pump chamber to be Factory waterproofed. l// 28. Vent provided if leaching below 3 feet or under driveway or parking. V� 29. Engineer to inspect and certify : a. clay removal -/ b. wall construction schedule / c. commercial system 30. Engineer and Land Surveyor stamp and signature. 31 . H2O loading when system subject to vehicular traffic. 32. Title V application and fee signed by a licensed installer. 33. Foundation footing 2 feet above adjusted water table. 34. Lot subdivided prior to July 31, 1986 - Nitrate Loading. 35. Subdivided prior io April 7, 1989 - Phosphorus Zone 300'. _.--- Plan reviewed by: 7