Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-23-003451
Commonwealth of Official Use Only 1.€$�^4 Massachusetts Permit No. BLDE-23-003451 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/21/2022 City or Town of YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 59 WINSLOW GRAY RD Owner or Tenant CONBOY KEVIN T Telephone No. Owner's Address POWERS KRISTEN E, 59 WINSLOW GRAY RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Chec •ppropriate Box) Purpose of Building Utility Authorization No. to Existing Service Amps Volts Overhead 0 Undgrd . • • Meter New Service Amps Volts Overhead 0 Undgrd <,‘", , 4 • O er Number of Feeders and Ampacity �_ Location and Nature of Proposed Electrical Work: Rooftop solar PV,9.6kW,24 panels O 1 �J ?.., Completion of the following tablebb ,i e t pector of Wires. No.of Recessed Luminaires No.of Ceil:Sus .(Puddle)Fans No.of Total p Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators t KVA No.of Luminaires Swimming Pool Above ❑ In- ElNo.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Jeffrey M Constantine Licensee: Jeffrey M Constantine Signature LIC.NO.: 16209 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 190 PLEASANT ST,ASHLAND MA 017211145 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 le431)417f CP.44-e (/ 0/73 RE,r • _.. Er ! ' ; DECg 2 Commonweal of rIlamachaseds Official Usc Only • �,' Nl cc7y cc77 Permit No. a;—3 Y.l 2epartineat o/lirr Services t' OccupancyOccupancyand Fee Checked L _ -11%,.i BOARD OF FIRE PREVENTION REGULATIONS ,Iro71 leave blank V APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK - All work to be performed in accordance with the Massachusetts Electrical Code(MEC).527 CMR 12.00 s (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 12/14/22 City or Town of: Yarmouth To the Inspector of Wires: s. C By this application the undersigned gives notice of his or her intention to perform the electrical work described below. o Location(Street&Number) 59 Winslow Gray Rd ti Owner or Tenant Adam Marcotte Telephone No. 508-280-7299 O Owners Address 59 Winslow Gray Rd West Yarmouth,MA 02673 i Is this permit In conjunction with a building permit? Yes NJ No ❑ (Check Appropriate Box) 1 Purpose of Building Residential Utility Authorization No. o ' O Existing Service 100 Amps 120/240 Vold Overhead® Uadgrd❑ No.of Meters U New Service Amps / Volts Overhead❑ Uodgrd❑ No.of Meters 0, Number of Feeders and Ampadty Building permit pulled seperately BI.1)-23-002649 Location and Nature of Proposed Electrical Work: Rooftop Solar PV Install.System Size: 9.60 kW DC Panels:24 v? Completion of the followingtable may be waived by the Inspector of Wires. l U. No.of Recessed Luminaires No.of CdSap(Paddle No. T)Fans Transformers KVA C' No.of Luminaire Outlets No.of Hot Tubs Generators KVA n -+ No.of Luminaires SwimmingPool Above ❑ In- ❑ No.of emergency Lighting firma. gent Li Batts No.of Receptacle Outlets No.of 011 Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of DetectionD and IInitiatingn Device '', No.of Ranges No.of Air Cond. Total No.of Alerting Devices Heat Pump Number Tons KW No.of Self-Contained Na of Waste Disposers Totals: Detection/Alerting Devices Municipal No.of Dishwashers Space/Area Heating KW "al❑Connection 0 Other Security Systeme:• No.of Dryers Heating Appliances KW No.of Devka or Equivalent No.of Water No.of No.of Data Wiring: KW Heaters Signs Ballasts No.of Devices or uMknt No.Hydronaaasage Bathtubs No.of Motors Total HP Teleco atiom Na of of Devices or E:1 eat OTHER: SOLAR Attach additional detail i/desired or as required by the inspector of Wirer. Estimated Value of Electrical Work: 7,700 (When required by municipal policy.) Work to Start: the inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such cirrage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND ❑ OTHER 0(Specify:) I certify,ander die pains and penalties ofpedal',that the information on this application is erne and complete. FiRM NAME: SolarFlair Energy Inc f/7,� '' /7 n0. LIC.NO.: Licensee: Jeffery Constantine Sigaaturi J � (,eKatLU1t cbJC.NO.: 16209A (if applicable.enter"exempt'in the license number line.) ! Bus.Tel.No.'508-293-4293 Address: 7 Inductrial Pares Rd Medway MA 0705 Alt.TeL No.: °Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: i am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner 0 owner's agent. Owner/Agent PERMIT FEE:S Signature Telephone No. I PHOTOVOLTAIC ROOF MOUNT SYSTEM AI11F418' 24 MODULES-ROOF MOUNTED - 9.60 kWDC, 6.96 kWAC 59 WINSLOW GRAY RD, WEST YARMOUTH, MA 02673 USA MyGenerotiaiEnectjy SYSTEM SUMMARY: CONSTRUCTION NOTE: (N)24-SOLARIA POWERX-400R(400W)MODULES A LADDER SHALL BE IN PLACE FOR INSPECTION (N)24-ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS • (N)JUNCTION BOX SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM , . (E) 100A MAIN SERVICE PANEL WITH(E)100A MAIN BREAKER A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC ; * o (N)60A FUSED AC DISCONNECT 690-47 AND 250-50 THROUGH 60 250-166 SHALL BE PROVIDED PER v NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING "}` (N)MA SMART METER =- (N) ENPHASE IQ COMBINER BOX 4 MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,OR IS ONLY a VERSION METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING 4�„"r" ii, +t'~ DESCRIPTION DATE REv ELECTRODE WILL BE USED AT THE INVERTER LOCATION ! INITIAL RELEASE 1W25(2022 UR DESIGN CRITERIA: CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN « 4 *- •ROOF TYPE:-ASPHALT SHINGLE CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO , NUMBER OF LAYERS:-01 LESS THAN#8 AWG AND NO GREATER THAN#8 AWG COPPER AND tf' ROOF FRAME:-2"X4"TRUSSES t 24"O.C. BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE r`• - / d STORY:-ONE STORY OR A COMPLETE GROUND. ',• SNOW LOAD:-30 PSF EACH MODULE WILL BE GROUNDED USING THE SUPPLIED '4" WIND SPEED :- 140 MPH GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER. `i • WIND EXPOSURE:-B EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE - 4 EXPOSURE CATEGORY:-II FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE ; ., GROUNDED. REGARDLESS OF VOLTAGE. ► PROJECT NAME PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING N r..' •• GOVERNING CODES: AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED; <{ ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY AND 2020 NEC. 2020 NATIONAL ELECTRICAL CODE(NEC) HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 2015 INTERNATIONAL BUILDING CODE (IBC) 6'7„ ' 2015 INTERNATIONAL MECHANICAL CODE (IMC) THE GROUNDING ELECTRODE CONDUCTOR SHALL BE 0 r, N W I 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE 1 AERIAL PHOTO O U GROUNDING ELECTRODE AND THE PANEL(OR INVERTER)IF W N O w O APPLICABLE CODES & STANDARDS: SMALLER THAN#6 AWG COPPER WIRE. THE GROUNDING PV-0 SCALE: NTS I- O O 2 BUILDING: MASSACHUSETTS RESIDENTIAL ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR Q O BUILDING CODE. 9TH EDITION.AS SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. O 2 J O Q ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT V - AMENDED(780 CMR) '_ I N SURFACES. # s?' FEIRCTRICAL: NEC 2020 E: MASSACHUSETTS COMPREHENSIVE THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED {` Y' _AO Q O F— O Co W FIRE SAFETY CODE(527 CMR 1.00) AT THE OPPOSITE(LOAD)END FROM THE INPUT FEEDER y •* + say c n O W LOCATION OR MAIN CIRCUIT LOCATION. , (I) O Z SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. sr,� �' wti < Z I� O O DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS _ SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT {�' jy4' I� Q O J (— SHEET INDEX OF CONSTRUCTION. �° t q w Vt Gray i th Q d) >- p 1-- PV-0 COVER SHEET to 1.0 PV-1 SITE PLAN WITH ROOF PLAN ~'Y as $ PV-2 ROOF PLAN WITH MODULES n ; b Q STRUCT ` , sit W Z PV-3 ATTACHMENT DETAILS ONL PV-4 BRANCH LAYOUT a4ovkOFIygss4`+ 7iSO t Q PV-5 ELECTRICAL LINE DIAGRAM �v c4- .? P1tile PV-6 ELECTRICAL CALCULATION • VINCENT "We z8 °` *� �� SHEET NAME ..., 1 IP- PV-7 ELECTRICAL EQUIPMENTS PICTURES " CIVIL PV-7.1 ROOF PICTURES MWUMVANEZA % 'Z''''. RW` ?�f�ItC s COP PV-8 WARNING LABELS APB : � 4,-� - - - -_ ,,� w Adventure Gol COVER S 4�r ONALVo 1 f SHEET SIZE NO 0 Revervitv4 Re ANSI B Signed 11/1/2022 9 11" X 17" ■ 2 VICINITY MAP SHEET NUMBER PV-0 PV-0 SCALE:NTS O m m PROPERTY LINE N mP _ -.- - __ `126.00' m v - z • .1--?, I• 1m I A ••Iz 70 m I. •1 w 0 _ 1 •1 n O m 0) m m m J' 'O :I mr ' 1, D .I o_ z I. I 1:/'1 I r t I ••10o 59'-1 h v I 1 CA) 1 /V I. ONE-STORY 1 HOUSE o e o 0 0 0 0 0 I 1 m 9 I 0 If� 32' 1" m 1 \ \ I \ i w Iwrn 1 01 \ 1 �1 — \� m Hi 21 z __ — r- - m1 I 1 —�- - .o — — 3 N'73 3NI��1�J3d0?1d °o N g It r0* I �SNIM ND, *.5/ I z a� )�° Mo 1 M x 4'0‘,, / D A _ oS 3 m 5 N=� 2 2 2 moo 2 Zi m n> m c coo Oz�a 70 N .:'a• a '4% r2 VgD 2 ; m m0n n < y 0. =�y\ �3z o Dm m A mO CO Z a \•«� zA A g > zm w y;t, Pzz a' w0 1 0 ^.74 1 0 S.° �� it' pm 3 m O ;1 X yy w D� N y�eR slOsCa�� T. Z A A 0 CO m Z m i n m O CA ADAM MARCOTTE mKIN N 0 N 59 WINSLOW GRAY RD, p = G z x Z °-uril WEST YARMOUTH, MA 02673 USA m P 2 A a w m 1 z APN#M:0040 B:00021 L:0000,2415122; z p - Z- m UTILITY: EVERSOURCE m AHJ: TOWN OF YARMOUTH s 0 MODULE TYPE,DIMENSIONS&WEIGHT • ALL EQUIPMENT AND CONDUITS SHALL BE PAINTED TO MATCH ARRAY AREA&ROOF AREA CALC'S ROOF DESCRIPTION THE BACKGROUND COLOR OF THAT LOCATION. ROOF ASPHALT SHINGLE NUMBER OF MODULES=24 MODULES • PLUMBING VENTS,SKYLIGHTS AND MECHANICAL VENTS SHALL S of ARRAY ROOF AREA ROOF TYPE ROOF MODULE TYPE=SOLARIA POWERX-400R(400W)MODULES NOT BE COVERED,MOVED,RE-ROUTED OR RE-LOCATED. ROOF MODULES (sa ) (SREA A Ft) COVERED BY ROOF TRUSSES RAFTERS MODULE WEIGHT=48.70 LBS/22.1 KG. ARRAY(%) ROOF TILT AZIMUTH SIZE SPACING MODULE DIMENSIONS=87.80"X 44.70"=21.05 SF NOTE:ACTUAL ROOF CONDITIONS AND RAFTERS(OR SEAM) 71 24 505,11 499.88 101.05 #1 37° 135° 2'k4" 24"O.C. UNIT WEIGHT OF ARRAY=2.31 PSF LOCATIONS MAY VARY.INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR PHOTOVOLTAIC MODULES ATTACHMENTS BILL OF MATERIALS SOLARIA POWERX-400R(400VV) MyGenerotIonEnecgy 87 80' EQUIPMENT OTY DESCRIPTION RAIL 13 SNAPNRACK UR-40 RAIL-14 FEET 168"DARK BONDED SPLICE 12 SPLICE KIT o CLAMP 42 MODULES CLAMPS(MID CLAMP) y CLAMP 12 MODULES CLAMPS(END CLAMP) ATTACHMENT 54 SNAPNRACK,UMBRELLA LAG.TYPE 3.41N,SS O ATTACHMENT 54 SNAPNRACK,ULTRA FOOT FOR U FLASHING, _ SILVER/BLACK VERSION ATTACHMENT 54 SNAPNRACK.COMP FLASHING,BIN X 121N, DESCRIPTION DATE REV 4P SILVER/BLACK ALUM _ GROUNDING LUG 3 GROUNDING LUG INITIA RELEASE 10/25/2022 UR SOLAR PV MODULE 24 SOLARIA POWERX-400R(400W)MODULES �e r 0 INVERTER 24 ENPHASE IQBPLUS-72-2-US MICRO-INVERTERS # JUNCTION BOX 1 FOR WIRE&CONDUIT TRANSITION NTED ON ROOF 0 COMBINER BOX 1 ENPHASE COMBINER BOX 4 AC DISCONNECT 1 AC DISCONNECT BOA FUSED,VISIBLE LOCKABLE LABELED DISCONNECT,240 VAC 1� 111 h.44119 rAl4 4S. PRODUCTION 1 MA SMART METER PROJECT NAME �1AETER N 040.,.. ' STRUCT " _ �A c6 ONL NOF� -M N Alt MASS�� 0 .. w Cc 6/04*** ���� VINCENT yG� W , NO O • 414140.� MWUMVANEZA N 0 CIVIL '0 ,/� m J ',0 Q 4,4+941 040to (N)SNAPNRACK UR-4O RAIL • EP �N``' Q' N 11-f ONAIE� � 0 LLI � -J p Signed 11/1/2022 -J p W Z Q 9 cA co .. Q �Q,, 9 ,< r^� LEGEND in } •• 1._ �. Q O I UM I UTILITY METER () Q \48W.#40 (0 � O� 17 -MAIN SERVICE PANEL j Za ff^^� n -AC DISCONNECT ' Q vJ n -AC DISCCOMBINER BOX SHEET NAME (N)(54)SNAPNRACK ULTRA RAIL ��� 4 *° ° JB -JUNCTION BOX ROOF PLAN WITH ATTACHMENTS SPACED AT 48"O.C. �� sioe �F �A �'S' n -MA SMART METER _ MODULES �� ��PC; O -VENT,ATTIC FAN SHEET SIZE (ROOF OBSTRUCTION) ANSI B • -ROOF ATTACHMENT 1 1"X 17" OROOF PLAN WITH MODULES �, RAFTERS .... -CONDUIT SHEET NUMBER SCALE: 3/16"=1°-0" J ,:' cxxl -CHIMNEY PV-2 © O >Cnr-o msZ - 1 -1 PC iZEP n 0 `pp mzo = = rKn Z-O m Z Z N..o aD-1 Z Z o F o m13cn D U) �mz —I Z n 0 ap mD m D m XE>x —I 0 to r —I oam v m Z rn9� D D > Z D -a (1) I- n T - � r Z� mZm Z m mmx m Zlpm Z T4'm Z om� �v3 r- mpo3> c m > Cn>-I O m m O t < 0 z-1z m -1 2 0 r CP n 0 T. r m • Z m -I VI. (/) Vit.‘ **44.,:+ 1 \ tlillitlikill‘li\ C..),n i G N 0 Iw A z 0 m m C O Z 0 7 2 D z niz ,Z c \ \ mHtn xcn ur Zr(/ ch m Z73 O> > arn O a' ->OO ' K >x m • ?Z • pZ 0 rip y T xDTw c O co • mOmtn xx > rZxC ,Zr ZO zc) W 3 00 DmgOO m E r om mm m z pOv -1 zA H r z Z O Z .\D6 �3 y0ry� c il H 0 �n • ' _ * Fv 1 m- D 0 0 0 -a a o.S. \. 0 3= i `. m L m A"ZZ 1 N = N ZFf4 4))3 c'44- S N m A ADAM MARCOTTE P F, E D 59 WINSLOW GRAY RD, p m i i' i z m o D m WEST YARMOUTH, MA 02673 USA m $ m al h i, 01 m D mg 1 APN#M:0040 B:00021 L:0000,2415122 s.; ; 2 A ? UTILITY: EVERSOURCE m AHJ: TOWN OF YARMOUTH i . 3 -8 m q) TW �20 N 13 D i(n5 D 0N) Z mmmo 0 m▪• = Nc r K m W D oCNt Q7 u m m N 0 C o K g 0 o m00 O oTr� z Rd 73 F r P m rn m z �-57 = S l')_ .4" to m °sue iC p0 D O a) 00 n b. 0 I- I C gm -7F 44.70" - A a r ADAM MARCOTTE N D N 59 WINSLOW GRAY RD, A m 1 13 1 ° z m 0 m WEST YARMOUTH, MA 02673 USA m m. a c co N D i APN#M:0040 B:00021 L:0000,2415122 ; Q ; g s g A o UTILITY: EVERSOURCE m AHJ: TOWN OF YARMOUTH p f SOLAR MODULE SPECIFICATIONS INVERTER SPECIFICATIONS AMBIENT TEMPERATURE SPECS SYSTEM SIZE:-24 x 400W=9.60 kWDC MANUFACTURER/MODEL# SOLARIA POWERX-400R MANUFACTURER/MODEL# ENPHASE IQ8PLUS-72-2-US WEATHER STATION:BARNSTABLE MUNI BOA (400W)MODULES NOMINAL OUTPUT VOLTAGE 240 VAC SYSTEM SIZE:- 24 x 290VA=6.96 kWAC RECORD LOW TEMP -18' VMP 31.00 NOMINAL OUTPUT CURRENT 111A AMBIENT TEMP(I-8GH TEMP 2%) 28° IMP 12.90 CONDUIT HEIGHT 7/8" VOC 37.30 CONDUCTOR TEMPERATURE RATE(ON ROOF) 90° ISC 13.68 CONDUCTOR TEMPERATURE RATE(OFF ROOF) 75° M.GC'nt!ratiOnEr18Rgy MODULE DIMENSION 67.80"L x 44.70"W x 1.40"D(In Inch) MODULE TEMPERATURE COEFFICIENT OF Voc -0.28%PC NOTE "LINE"ON THE TOP OF THE METER IS FOR THE UTILITY 'LOAD"ON THE BOTTOM OF THE METER IS FOR PV GENERATION 12 MICRO-INVERTERS IN BRANCH CIRCUIT#1 ... VERSION DESCRIPTION DATE REV t - r BI-DIRECTIONAL INITIAL RELEASE 10126/A22 AR e Ie V METER-W, I-PHASE.3 120V240V,60Hz ---- -01 12 MICRO-INVERTERS IN BRANCH CIRCUIT#2 LINE SIDE TAP (N)AC DISCONNECT. l I l�- I I (N)JUNCTION BOX 60A FUSED,40ARP PROJECTAME I/'V 'V I (N)MA SMART METER FUSES,2LIS NEMA 3R I '— aT�—J y (N)ENPHASE 10 UL LISTED, — ■ �• II.\ ^ COMBINER BOX 4 (E)t00A MAIN t LINE r 4W vases SERVICE PANEL + I • p SOOA WITH(E)100A CO ENPHASE IOBPLUS-72-2-US I - 11]i�I�ATeT ( I .—.�r.� MAIN BREAKER Q r (V w MICRO-INVERTERS I C M I (Z- (TOP FED) W W CO Ci CV Q U Q TERMINATOR CAP ON LAST O-CABLE I �c4 I-—1-1 L-- 1;1 — —-1 �— r ,_ CJ Q CONNECTOR(TYP) I —it'd I I 4 CI — Z Q C) D Ct I G I I I I I LOAD I Q 2 J Q I�- J ---- J I L---J n_ U 0 _r (n 2 o 5 c)c) > Q (3)#8 AWG THWN (3)#6 AWG TH WN (1)#8 AWG THWN GND (1)#8 AWG THWN GND �J C U) Q , Z I I IN 3/4"EMT CONDUT RUN IN 3/4"EMT CONDUIT RUN G I- J aZ � � � � Q > Qo I— (2)O-CABLES (4)410 AWG THWN-2 EXIS_TING LC) c D i (1)PV 48 BARE CU GND IN 3/44""EMT CONDUIT RUN AWG THWN-2 GND GROUNDING w It Q . • a Q SHEET NAME ELECTRICAL LINE SERVICE INFO. DIAGRAM UTILITY PROVIDER: EVERSOURCE SHEET SIZE MAIN SERVICE VOLTAGE: 240V ANSI B MAIN PANEL BRAND: SIEMENS MAIN SERVICE PANEL: (E)100A 11"X 1711 °ELECTRICAL LINE DIAGRAM MAIN CIRCUIT BREAKER RATING: (E)100A SHEET NUMBER MAIN SERVICE LOCATION: NORTH-EAST SCALE: NTS SERVICE FEED SOURCE: OVERHEAD PV-5 • AC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: IN FROM JUNCTION BOX TO ENPHASE IQ COMBINER BOX 4: FROM AC DISCONNECT TO INTERCONNECTION: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT #OF INVERTERS:24 PER NEC 310.15(B)(2):7/8"RULE EXPECTED WIRE TEMP('C):28' EXPECTED WIRE TEMP('C):28° TEMP CORRECTION PER TABLE 310.15(B)(1):1.0 TEMP CORRECTION PER TABLE 310.15(B)(1):1.0 #OF CURRENT CARRYING CONDUCTORS:3 #OF CURRENT CARRYING CONDUCTORS:4 CONDUIT FILL PER NEC 310.15(C)(1):1.0 CONDUIT FILL CORRECTION PER NEC 310.15(C)(1):0.80 CIRCUIT CONDUCTOR SIZE:8 AWG MyGenerationEnergy CIRCUIT CONDUCTOR SIZE:10 AWG CIRCUIT CONDUCTOR AMPACITY:65A CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A8B): 1.25 X#MICRO-INVERTERS X MAX OUTPUT CURRENT= 1.25 X#MICRO-INVERTERS(MAX.BRANCH LENGTH)X MAX OUTPUT 1.25 X 1.21 X 24=36.30A CURRENT 1.25 X 12 X 1.21 A=18.15A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16: TEMP CORR.PER NEC TABLE 310.15(B)(1)X DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15(B)(1) CONDUIT FILL CORR.PER NEC 310.15(C)(1)X VERSION TEMP CORR.PER NEC TABLE 310.15(B)(1)X CIRCUIT CONDUCTOR AMPACITY= DESCRIPTION DATE REV CONDUIT FILL CORR.PER NEC 310.15(C)(1)X 1.0 X 1.0 X 65=65.BA iNITAL RELEASE razvmfz un CIRCUIT CONDUCTOR AMPACITY= 1.0 X 0.80 X 40=32.OA RESULT SHOULD BE GREATER THAN(36.30A)OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY . -- - RESULT SHOULD BE GREATER THAN(18.15A)OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY AC CONDUCTOR AMPACITY CALCULATIONS: FROM ENPHASE IQ COMBINER BOX 4 TO AC DISCONNECT: #OF INVERTERS:24 PROJECT NAME EXPECTED WIRE TEMP(°C):28° N TEMP CORRECTION PER TABLE 310.15(B)(1):1.0 Q N #OF CURRENT CARRYING CONDUCTORS:3 Cl) Lo CONDUIT FILL PER NEC 310.15(C)(1):1.0 D _ CIRCUIT CONDUCTOR SIZE:8 AWG co R CIRCUIT CONDUCTOR AMPACITY:SOA CVIY CJ O U LU REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): I- > O O 1.25 X#MICRO-INVERTERS X MAX OUTPUT CURRENT= 1.25 X 1.21 X 24=36.30A I- 2 0 Q < T- U7 DERATED NuPACITYOFCRCYIR CONDUCTORS PER NEC TABLE 310.16: f: > I N t TEMP CORR.PER NEC TABLE 310.15(B)(1)X Q > H O W L� C RCUCONDUT CONDUIT FILL OCRITOR AMPACITY R.PER NEC 15(C)(1)X O 0 OO UJ z 1.OX1.0X50=50A < z 2 O RESULT SHOULD BE GREATER THAN(36.30A)OTHERWISE LESS o V H O THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY Q > < 0 J H rn } 9 in ELECTRICAL NOTES w Q 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. > d 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90 8 75 DEGREE C WET ENVIRONMENT. > Q 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. SHEET NAME 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL ELECTRICAL APPLICABLE CODES AND STANDARDS. CALCULATION 6.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. SHEET SIZE 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E.G.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. ANSI B 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE 11 X 17" -oELECTRICAL CALCULATION SHEET NUMBER SCALE: NTS PV-6 m Apr 'r s : 7,11 � :17.,: . _ C) �\ D ' .. 11„,,,,...419 , M J r ..,_. ..c _c, I a z _-r (I) n m c ,t z rn c T. -- TI"a"e"IUL ; A . r.f4.7"'.w urn vr' i I,rt,.OR M bRn!�a41 trwr. 1 N , sn...l..e.....4—� • nra.ow M4HwQ Mw..r lamp s asai•'r -. a, i I . i x5 t r ,/`— :ire. . �.- ADAM MARCOTTE s m N - o i-y 59 WINSLOW GRAY RD, A m y < = x El-]�� WEST YARMOUTH, MA 02673 USA ° m 2 p a " ,ri�> APN# M:0040 B:00021 L:0000.2415122 S v 0 4 J m �I O7 m f1l � v m z m - `�cn 1m UTILITY: EVERSOURCE m 2 AHJ: TOWN OF YARMOUTH A 7) O Z m . . ,. + I - '° 1i -1' m r if, s ¢ "1 � 111 > �z> * err *m , A ' i J µ` A N a1e. t ° f - D jj ,., a p. r "e ram.^: n , — 144 r Q r ADAM MARCOTTE 3 n 3 NI m ; D = 00 59 WINSLOW GRAY RD, A » o 31 Z X v WEST YARMOUTH. MA 02673 USA m 2 p a Z APN# M:0040 B:00021 L:0000.2415122 ; te,N v. z m ,,m V O7 m C m m UTILITY: EVERSOURCE m AHJ: TOWN OF YARMOUTH A < A WARNING j PHOTOVOLTAIC AC DISCONNECT , r - 4, / IV MAXIMUM AC OPERATING CURRENT 29.04 AMPS ELECTRICAL SHOCK HAZARD NOMINAL OPERATING AC VOLTAGE: 240 VAC SOLAR PV SYSTEM EQUIPPED TERMINALS ON LINE AND LOAD LABEL LOCATION. SIDES MAY BE ENERGIZED IN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF WITH RAPID SHUTDOWN THE OPEN POSITION INTERCONNECTION. PER CODE(S).NEC 2020:690.54 ` • LABEL LOCATION' PHOTOVOLTAIC POWER SOURCE INVERTER(S),AC DISCONNECT(S),AC COMBINER PANEL(IF APPLICABLE). LABEL LOCATION. PER CODES)NEC 2020 NEC 706.15 EMT/CONDUIT RACEWAYS M TURN RAPID SHUTDOWN (C)(4)&NEC 690.13(B) (PER CODE:NEC690.31(D)(2) SWITCH TO THE"OFF" SOLARER PP" MAIN PHOTOVOLTAIC POSITION TO SHUT DOWN PHOTOVOLTAIC SYSTEM DISCONNECT PV SYSTEM AND REDUCE VERSION DESCRIPTION SHOCK HAZARD IN THE DESCRIPTION ogre Rev LABEL LOCATION. 1111 INMAL RELEASE 1E25/2021 UR MAIN SERVICE DISCONNECT/UTILITY METER ARRAY. (PER CODE:NEC 690.13(B)) AC DISCONNECT FA LABEL LOCATION: WARNING \ \LABEL LOCATION' ' AC DISCONNECT ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING NEC 890.13 B) THIS EQUIPMENT FED BY MEANS To WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S)'.NEC 2020:IFC 690.56(C) MULTIPLE SOURCES TOTAL ,.DUAL POWER SOURCE RATING OF ALL OVERCURRENT PROJECT NAME --'" •" ,SYSTEM DEVICES EXCLUDING MAIN POWER (V LABEL LOCATION' SUPPLY SHALL NOT EXCEED Q N POINT OF INTERCONNECTION AMPACITY OF BUSBAR _ CAUTION ! _• in PRODUCTION METER NEC 705.12(B531(3)&NEC 690.59) ' i LABEL LOCATION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE CI I` N LLI WARNING POINTS N OF CONNECTION/BREAKER REAKER FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN (N O CODE.NEC 705.12(Bx3)l3) LLI CV O U 0 POWER SOURCE OUTPUT AT:® MAIN SERVICE PANEL&UTILITY METER,AC ~ J- 0 O CONNECTION RAPID SHUTDOWN FOR DISCONNECT&ENPHASE IQ COMBINER BOX4 ~ Q O DO NOT RELOCATE THIS SOLAR PV SYSTEM 00� Q o x: OVERCURRENT DEVICE LITIE L LOCATION. -LYOCRTIONENTRANCEMETER,INVERTERDC O D 00 WO LABEL LOCATION' DISCONNECT IF REQUIRED BY LOCAL AHJ.OR C C U) cO Z> SERVICE PANEL IF SUM OF OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. < Z C O BREAKERS EXCEEDS PANEL RATING PER CODE(S):NEC 2020.690.56(C)(2) NEC 706.12(B)(3H2) EC O< > Q O J CT } 9 — .. NOTES AND SPECIFICATIONS: " CO Q •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE THE DISCONNECTION of THE Z W Z 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS GROUNDED CONDUCTOR(S) CL ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE MAY RESULT IN OVERVOLTAGE at LOCAL AHJ. ON THE EQUIPMENT Q •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS LABEL LOCATION SHEET NAME USING EFFECTIVE WORDS,COLORS AND SYMBOLS. INVERTER (NI PV MODULES—.... •LABELS SHALL BE PERMANENTLY AFFIXED TO THE PER CODE.NEC 690.31(E) WARNING LABELS EQUIPMENT OR WRING METHOD AND SHALL NOT BE HAND WRITTEN. •LABEL SHALL BE OF SUFFICIENT DURABILITY TO VNTHSTAND SHEET SIZE THE ENVIRONMENT INVOLVED. •SIGNS AND LABELS SHALL COMPLY IMTH ANSI Z535.4-2011, ANSI B T PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERVNSE (N)AC FUSED DISCONNECT (E)UTILITY METER SPECIFIED. 11"X 1 7" •DO NOT COVER EXISTING MANUFACTURER LABELS. -(N)MA SMART METER -(N)COMBINER BOX SHEET NUMBER —(E)100A MAIN SERVICE PANEL WITH(E)100A MAIN BREAKER(INSIDE) PV-8 S O L A R I A Solaria PowerX I DC Panel SO L R I A Solaria PowerX-40OR Pe'formancealSTC'ronOV;.m ,r,.r AM;51 M..+h e,"nr•,t. n+. Solaria PowerX AOUR Performance Series MaxSolana eow..x- J1me 395a 48a" Cell Type MondayeUhneSilicon Max Power IP^'•s) (WI 390 395 400 Dimensions O.x W e HI 67-8'x 44.7'x 1.4" Efficiency [% 20.0 20.2 20.5 1723mm x 1134mm x 35mm Open Cncuit Voltage(Vxl (V 36.9 37.1 37.3 Weigh; 22.1 kg,48.7 lbs Short Crow Current(1sc1 (A 13.52 13.60 3.68 Glass Type I Thickness AS Coated,Tempered;3.2mm Ach+evmi Cyr 20.Pa efficiency.Solar•a PowerX Perf0rTxanen solar.,oriels feaWle Max Power Voltage(rim) (V 30.6 30.8 31.a Frame Type Black Anodized Aluminum Sd811a5 core cell cutting t_rhrc.ogy.ortenng higher power and sttrac'!nw 1tL0 k-inn Max Power Current(Ina) (A 12.73 12.82 12.9 cube type/I ength 12 AWG PV Wire(ut l/t I oDmm black aesthetics cnmparec to conventional solar par1e15,So4ina has been-he market Power To erance [% -0/43 -0/s3 r • Connects Type MC4 leader lr cet-cell tecnnole g'Ps tce cue a decade.With a coreprehensu,c 25 year J+ancttnn Box 11.68/3 diodes warranty PowerX celisers Ire latest In pDWCr and reliability"r homeowners - • `' - Front Load 5400 Pa:113 Dsl" Mae Power(Pmax) (WI 290 293 297 Rear Load 2400 Pa/50 ps1• Open Circuit Voltage(Vic) [V] 34.3 34.5 34.7 "w•^•,•a*sr•+"•°aan.•'a+a^'= Short Creole Current(ley) (A] 1101 11.10 11.13 .,.. ; -+ High Efficiency,High Power Max Power Voltage(Uwe) (VI 28.50 28.60 28.76 \f ea403 We. rr.tr;5`-Olio ency SO,Fig Pow rX solar panes Max Power Current pia) (A] 10.20 10.26 1D.32 cart hrarona UL 61730/1EC 6121S/IEC 61730 are Mr-+ nr t'mst 7riwer'eslCenba panels i adahie Fire Type(UL 1703) 2 NOCT VT] 45.7-2 Power,Pets 8 Labor 25 years. TempCoeff.of Pro, Warranty (%/°CI -0.36 .w,,,i,v s+vra.,.amr.ca. High Quality and Reliability4 Temp Coeff of V. (%/•q o 2e I",..ilf TempCoeff_of Inc [%I"CI 0.048 ales, +r tF t T ,r d„a+ s tit'1ehlr a dl:" - --.-. Stacking Method Vertical °alletized -1 n.1 des crnr t;far ea ned'he industry-leach.q 25'vein Operating temper ewe [•C] 40le•95 Panels;Pellet 31 warranty Pallet Dens it x W x H) 69.3'x 41.3'x 49.3' Max System Voltage (VI 1DW Max Fuse Rating [A] P5 1760mm x 1125mm a 1253mm I Pallet We ghl 745 kg/16421bs All Black Aesthetics `t BYPass Dlodex let 3 Pallets/40-it Container Ccerpani'floc",lrenhnn2lpanelS,SOlanaFOaelxpanels About Solaria rr:- Irr<d.ance1403WPanel) Pandaia0-flG,nnlalner 806 . " ha'vearrvreundom-aublakappeaeance. EstabGShed:n2000,The Solaria .att. Corporation has created one of Ia - . "- the industry's most respected IP I' . z- Best System Value ,+i r• , portfolios,with over 250 issued and NIJ Solon POaerx soar panels produce more pinner per square pending patents in PV solar cell and mete,area The;red JCes mstaaahon c00t5due to fewer module technology.Headquartered • haance r t system components in California,Solaria has developed a , .... technology platform that unlocks the ` -'ii p y� potential of solar energy. ' '. /�/�,.\ Improved Shading Tolerance TaLr r L`��I,1\ Sub-strings are mterconneredm parallel,wilco dramatically n°r'M lowers the shading losses and 30051s energy meld .. .. • 's-yea.Pit Potts nmbar 1tla,r 111 : Zs:. Low Light Performance tray 1 I i mstrr erra•n a I , �. fir\, re. � PowerX maintains mgh efficiency at low mad ante further n n,unnq nax�mum energy'meldeld AL u: i�� n n 9 „ IIIw, ihetinarsCrr r 1+ll.x'h rr,Tint d.i7. rnrri nin FTC!f mnn'I:A n45ta -;Sint n-^:a' er.•....,,* :nnr.,tt. .I';'7h-.. I: I,ti•, .G' . ENPHASE a JOB Series Microinverters so sr....an..,m. m. tows wledse aw Ilued• ,.m +Pos[e.teur pow asere averr.e.a.c.a.a w..•. ,... .p a,...r.... ..•rbanw NJ SOO NO 325 ma Ws We MO 1 «s..wpo«ww.w . >+e NO m au as sa.r..MO rta wserwo IQS Series Microinverters tyres we . weeserd Easy to Install Our newest IOE hecromrerters we the iM l first nAaogrl6Mmbo.software- •LpM g weroht end compact with screws rr.aiewwsew w.. s e4 dMlrrM moron with split-phase power corwerion c.pablitr to convert DC do,Phis c as r.w.,,n..oa Lt.o-.r✓ew.m a s n n n e n atram al the semiconductor-cased re oranwne• .Power twee Commurxulbn wow v apoka x(AM^)whim IplGl h.wrasnc .weers rw.iw..w,w a.wem .sa rercranverres n - - nbdee Twsc c cre..x•o..r.ce., • hh .,wchnomov with hogh trews,h°eennonb and has super-feesmesgmse Whirr nst•tetwnwm simpte y_sswro:.rea.we SO to clang.°loads sod grb went.all.viating constrarnw on balers steno for home two wee cabling vnnw.rev..., c erterw.wtwn., Woh wearotivlos and reliability ue we.e.n r.cw aeamin oasw.eae•ae air •Comodouwo-IYonied the .nnsrrewsw.„ .w .. toe aptr..ao•e+w.w.ed,rl �w than ore milk..nmw.1 VO 22.11 al WV. • csc • Class I double-Insulated enclosure {.241.2.2.421121..20. ....1212112......22 m..ret...4ems.we, n,.eaawe.�.nu.uv rnmded la M.IaH.t high- m1m. sc. ere.. ., WN^°tlub ors oweerweer.w,or nz...res r.ne..na.r.wzamrvl G.. tEl.r.w�b Loal.uxm O •Compiles w.hthe pa- cowerserws.�.rwrs v�.,w wea®,wr. advanced ab+,war. CERTIFlEO •°emote eACTellC wmtaslor un.. lnehtas1 ondrsau.wwrla Endow. .n..�wnw•amwaawaw. s .Conft,shle to woo.a woe. w.w.e.wwvrwm.•aa. c.0 weWen-Wucam.eete. mwaeecawsgww range of grid prow.s swaaarw,.er weaw .Wets CARuk 21 WL slat-PA) repu..meaw creWew t .. ..r-,.. .n...:....u. _... .. .......:pw.ec pn...rCc.wo.ce.n u Maws..fnon r.a.E,aree.m n e..wi.arw•mmires .mow, .nw.w..aam.e..uw..wer.n.o..•Ma-..u...w �m,...,Na..ceni.wiw�cw..nun s 1..n........voub,u bum.000iaci.ux.22,-, ow ewer.,. w mw r�w i °w.wvc.ne.r.ea.mnn�rsrw.h w+nrsr beffo.-wmrn,vw,m,-are 1 a ♦ s • la • CI a 4. ^r ^ 10 an g 0 ea D D 0 w ii x q �''"b J .J -' °> N.) N U) o ➢ A A (D x 3 L CDCD —. 3 ma .O 7 t A A n al At no rn _. J 6 N Lr --, C 5 -. -t p N co a '' co w O 3 O r m 0 7 '9 3 D- r n re Z : - O - O c C 4 z g .e A n O C: if n f, U in O n r. O o s y nQ a v_ ° g Y g3 r' ctr W 16 p a K J, a. • o v 1 N o R. D33 'a o .' 4 a d Q - m 0 tr) c a. c� '" u± .., • n> m z _ o c d 3� A _ o `�P" a_ o Cr a_ N 1 0 70 a _a o I �CCC ➢ 3- - c c n v ` , 5 3 3 a - y .� * 2 t in -a n w • D . m _ �m g s c ^ iq -+ J a T. G� n' $ O(J c O n 0 T s q o t O U _ O A • z y i N m a A rJ D m .0. Cu ▪ m o ! E. cn m � E � W d .0 t y CI ro < 2 .0 3 a o m m .z c N — c v 5 z ,o ,� a R. o p O 2 2 7 D _ .‹ - 3 ID r {/ y t4 Y _ C Q -° al I rn o n ; 2 It $ T n > < 4 ; n 7 ; m ; ; �.' U r m x x x x T s m m s m nt) m )3 i R x 3 n 3 to ` 0 w i y 1 g _ r a P . P I. 10 32 m M a na 9m 3 ' SaS .z ..3 �+ - k . . P > 3 13 rTi z z • ! p cl y "y-. -.$ � m�' t i x 2 m 1 •➢ < C r O -- - a zs In 1 4 ID " c, 3 4 1 a g '1 5 i � tiNit" c �y fin+ O a o I r i, i a ] a NI . asA .� u rr' aov{ ' S SpQ T y zo _ ^ . Oa ^ b ,5 Q � a xa o 3j z � ix j ➢ - Li r a �7 O n p Du o MI 3 T 1 f Z Z A, • v s �, m 0 p i� _ ' •7r • yr rs E 'f'. ,' '� . > f.> r•: a •e c�^�i n c a a m Y A Ci D CI O r C r b ff v n G d �; T. L p' A ➢ D N J , 5 O ., .,i A Ci i Q Rw 7 J. g;=Zh HNn s o Ete I -si a ➢n 4 d o ,,. ➢ s i _ cc c.' gS 3 ri; �I i - 4°n. r o c e •_ .an ., z z i v, - ? g a. g. .% 3 $Y i�" na c m gU� 2� iy i2 i $ � ? ^� Fi� i � n a 9 - _ $ v Y c a- 3 # 3 Z 32 .' t. i�i f +ae ^;?3� .,.. ' b f5 "' 7. ; a av r - n ^ n ' 1 o $ o it I `_ n.TreCi4 h r.n et ? Z p3 " y S g o T as a trvrJwnJA t;� ! ❑ � soa ," in s cg Lg7 . s. A r ' 8 0�'00'0 +' � na':e_3 Nn � a • a $S�I .� j�: t o _� a c q$y 3 n / ; g T e 3 p 2 2 2 t, m y v y r+ '. 4 ac o 9 Z s !, : Cs a N'N-:¢ it Oj az a - - 7 a i -a . i3'" S " -. .1 a o s u Y “7?3..n, 2 masf)t B T. n a 4 O O , 0 a _ - r c, 3 v¢nvnomv QO 70 - w2 • srr7. s oYD Z - - $ £ > 4 wiv.sio , ! ill a ; n' ➢S f s 3 Y i g # Z x g ;, t o NJ .T O t g g V p . a o:n a i o p a�w t C 2 g s r '�j3 a 3 k a i, ` A ; c`^, 3 y a yyrr F a _ @n r, a n1 2 j ° IU a F vo T 2 4.<w P0TS I• S7 y S 4p z j O u i 1 . o 3 1. 5. ? 3 l a - of 384 II K I r f n 3 T` +T m 0+ Cr n A a g e'q Z 7 g 4- 0R' z - -: 3 $ o I 3l@ > � ' ' - n m I t to m • 1 I a DESCRIPTION. DRAWN BY', DESCRIPTION: DRAWN BY SNAPNRACK,ULTRA RAIL COMP KIT mwrtWns SNAPNRACK,ULTRA RAIL COMP KIT mwatkIns REVISION: REVISION. PART NUMBERIS) r u. PART NUMBERIS). SEE BELOW — —,= SEE BELOW UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION C 242-01219 ULTRA RAIL UMBRELLA L FOOT,SILVER A :7 242.01220 ULTRA RAIL UMBRELLA L FOOT,BLACK 1.37 1.00 L SLOT 1 1 1 1.50 3.25 2.78 1.78 r 1.62 H — .30 25 2 H. 1.80 r H 1.50 H 1 A COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FlASHING,9"K 12",BLACK ALUM 232-01376 COMP FLASHING,9'K 12',SILVER ALUM 232-01377 COMP FLASHING,9"K 12",BLACK GALVALUME 1 1 .30 — 01.00 • 6.75 1 1 3 11.75 PARTS LIST 1 ITEM QTY FART NUMBER DESCRIPTION _ 0.20 1 1 242-92266 SNAPNRACK,UMBRELLA LAG,TYPE 3,41N,SS I05° 2 1 242-01219,242-01220 SNAPNRACK,ULTRA RAIL UMBRELLA L FOOT,SILVER/BLACK 3 1 232-01375,232.01376,232.01377 SNAPNRACK,COMP FLASHING,9IN K 12IN,SILVER/BLACK • MATERIALS: 6000 SERIES ALUMINUM,STAINLESS STEEL,RUBBER 0.35 DESIGN LOAD(LBS): 802 UP,1333 DOWN,356 SIDE 3.25 ULTIMATE LOAD(IBS): 2005 UP,4000 DOWN,1070 SIDE TORQUE SPECIFICATION: 12 LB-FT 1 1 CERTIFICATION: UL 2703,FILE E359313;WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 8.75 WEIGHT(L85): 0.79-1.03 ALL DIMENSIONS IN INCHES SnapNrack UR-40 SnapNrack Ultra Rail System UR-60 A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profiles; UR-40 is a lightweight rail profile that is suitable for most geographic Ultra Rail regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profile that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts,module clamps,and accessories for ease of install. The Entire System is a Snap to Install _ :-- -1 •New Ultra Rail Mounts include snap-in brackets for =� �-- .>>> --- attaching rail --�� \i/ I 10°1 •Compatible with new Ultra Rail Mid Clamps&End Clamps that are one-size-fits-all universal clamping height •Universal End Clamps&snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management •Open rail channel provides room for running wires resulting in a long-lasting quality install --f � •New module clamps eliminate bolt interference �� in the rail channel creating more space for wire / management •Industry best wire management offering includes The Ultimate Value in Rooftop Solar Junction Boxes.Universal Wire Clamps,MLPE Attachment Kits&Conduit Clamps •System is fully bonded&listed to UL 2703 Standard 9 Industry leading Wire �//A Mounts available for all Management Solutions �H roof types Heavy Duty UR-60 Rail •UR-60 rail profile provides increased span All SnapNrack Module capabilities for high wind speeds and snow loads Single Tool Installation Clamps & Accessories •Taller,stronger rail profile includes profile specific rail splice and end cap are compatible with •All existing mounts,module clamps,and both rail profiles accessories are retained for the same great install experience Start Installing Ultra Rail Today RESOURCES snapnrack.com/resources Quality. Innovative. Superior. DESIGN snapnrack.com/configurator SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. WHERE TO BUY snapnrack.com/where-to-buy 877-732-2860 www.snapnrack.com contact osnapnrack.com 4 4 111 A •