Loading...
HomeMy WebLinkAboutBLDE-23-002913 of Commonwealth of Official Use Only fi_Afi_ Massachusetts Permit No. BLDE-23-002913 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:11/28/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 16 BENJAMIN WAY Owner or Tenant HIGH ALTA M Telephone No. r Owner's Address 16 BENJAMIN WAY, WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Approp(i 'e o>yf�Purpose of Building Utility Authorization No. r 7 Existing Service Amps Volts Overhead 0 Undgrd :No:-of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(24 Panels 8.84 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting rnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices , , No.of Ranges No.of Air Cond. Ton l No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 VE - ---� I or nwealfh o////aiiachueeit Official Use Only 2 OV2 �22 Parlment oi lire �ervice9 Permit No. �_e.� �� 1 Occupancy and Fee Checked O DI-Na361140PIQFE }R PREVENTION REGULATIONS [Rev. 1/07] (leave blank) TI R PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: i a 3 ) as City or Town of: \In rmpv�-1n To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) t La ►oQ,n\��\.in � C,(_l)1 -7 Owner or Tenant Pk l -� j (� n J nn _ �J Telephone No. �� a 3 /7 Z... .$') Owner's Address 5 0 MI cL`' Oi �--C- Is this permit in conjunction with a building permit? Yes YI No ❑ (Check Appropriate Box) VPurpose of Building Utility Authorization No. Existing Service Amps I ` /L,OVolts Overhead n Undgrd' No.of Meters New Service Amps / Volts Overhead ElUndgrd 1-1No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: . dCompletion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total : Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA !p No.of Luminaires Swimming Pool Above ❑ grnd.In ❑ BateUnits Emergency Lighting U grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones (� No.of Switches No.of Gas BurnersTota No.of Detection and �}.J Initiating Devices No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Dis posers Heat Pump Number Tons KW No.of Self-Contained Vp Totals: Detection/Alerting Devices No.of Dishwashers S ace/Area HeatingKW Local❑ Municipal ❑ Other P Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: JHeaters KW Signs Ballasts No.of Devices or Equivalent d No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring: Y g No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: r(t6b 1 .as (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. 1 FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally (^)' required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent l PERMIT FEE: $ Signature Telephone No. ;pnc • 0.114 .-. SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE # DESCRIPTION • SYSTEM SIZE. 8640W DC. 6000W AC • ALL WORK SHALL COMPLY WITH MA 9TH ED CMR 780 (2015 IRC/IBC/IEBC). GO SERVICE ENTRANCE PV-1 .0 COVER SHEET • MODULES: (24) LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE. AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION LTD: LR4-60HPH-360M INSTRUCTIONS. PV-2.0 SITE PLAN • INVERTERS: (1) SOLAREDGE TECHNOLOGIES • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020 (MP) MAIN PANEL SE6000H-USSN PV-3 0 LAYOUT • RACKING RL UNIVERSAL. SPEEDSEAL TRACK ON COMP. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020 PV-4.0 ELECTRICAL (sr) SEE DETAIL SNR-DC-00436 SUB-PANEL PHOTOVOLTAIC SYSTEM IS UNGROUNDED NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER SYSTEM COMPLIES WITH 690.35 • EXISTING SOLAR SYSTEM INSTALLED 0 PV LOAD CENTER • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703 • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741 CI SUNRUN METER • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703 PM DEDICATED PV METER • SNAPNRACK RACKING SYSTEMS. IN COMBINATION WITH TYPE I, OR TYPE II MODULES. ARE CLASS A FIRE RATED INV INVERTER(S) • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690 12(1). AC AC DISCONNECT(S) • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G) DC • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT DC DISCONNECT(S) • 11 35 AMPS MODULE SHORT CIRCUIT CURRENT. (CB) IQ COMBINER BOX • 17.73 AMPS DERATED SHORT CIRCUIT CURRENT [690 8 (A) & 690.8 (B)]. \ • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). ABBREVIATIONS F —1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT sunrun AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (E) EXISTING FLUSH ATTIC VENT VICINITY MAP ,95MYLESSTANDISHBLVD TAUNTON MA 02780-7331 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT Boston PFAH,(OONE0 EXT EXTERIOR METAL PIPE VENT CUSTOMER RESIDENCE INT INTERIOR ALTA HIGH T-VENT IIVP MSP MAIN SERVICE PANEL 16 BENJAMIN WAY. YARMOUTH. MA, 02673 (N) NEW SATELLITE DISH ence 16 Benjamin Way, NTS NOT TO SCALE West Yarmouth, MA... TEL. (508) 862-6377 OC ON CENTER FIRE SETBACKS �'[� APN• YARM 000064 000053 PRE-FAB PRE-FABRICATED `ice PROJECT NUMBER. PSF POUNDS PER SQUARE FOOT HARDSCAPE 0 D E 223R-016HIGH PV PHOTOVOLTAIC A N D Nantut`ket DESIGNER: (415) 580-6920 ex3 RSD RAPID SHUTDOWN DEVICE — PL— PROPERTY LINE o AMY CYZMAN TL TRANSFORMERLESS SOLAR MODULES SCALE: NTS SHEET TYP TYPICAL ' �' REV NAME DATE COMMENTS COVER SHEET V VOLTS W WATTS Fi '� H Cil REV: A 11/23/2022 LAN LANDSCAPE V 0 PAGE SNR MOUNT PV-1 .0 POR PORTRAIT SNR MOUNT & SKIRT - Template_vers1on_4 0 87 SITE PLAN-SCALE=1/32"=1'-0" SITE PLAN DETAIL-SCALE=NTS T 7--____ —7 PL _— _______ PL (E)PV EQUIPMENT -, rMP SE (E) a SE (E)DETACHED t STRUCTURE (N)ARRAY AR-01 AC IC INV LC PM I,"I ilbo, 77 4 ✓ . �,\ - (E)RESIDENCE a \:11* .' ..;O:Hifr--,;:,:l. \>V \ \ Ix \ PL 4V\ 0 o sunrun (E)RESIDENCE \ \ \,<)\ \• #180120 \ \ \ 6.SAES STN1g5H BLw.TAUNTON,.02780-7v1 \ \ PRUNE 0 �/ 0 \ \\ O / CUSTOMER RESIDENCE: ALTA HIGH 16 BENJAMIN WAY,YARMOUTH, / \\ MA,02673 (E)PV ARRAY -- \= ARRAY TRUE MAG PV AREA TEL (508) 7 APN:YARM-000064-000053 PITCH AZIM AZIM (SQFT) PROJECT NUMBER: AR-01 36° 54° 68° 470.6 223R-016HIGH DESIGNER: (415)580-6920 ex3 AMY CYZMAN SHEET SITE PLAN REV:A 11/23/2022 PAGE PV-2.0 rempete-ve a 4087 ROOF INFO T FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF 13'- RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10., 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW D1-AR-01-SCALE:3/16"=1'-0" 5/16":2.5"MIN.EMBEDMENT AZIM:54° PITCH:36° • _--U- 13-10"_ _ _ • • �� • • 17'-10" 34'_10" • 3-8" Y _- _.+ s u n r u n STRUCT 0 #180120 I ��Fy11N OF M4S`�4 INSTALLERS SHALL NOTIFY ENGINEER OF ANY ees urns sruaoisn eiw.*•u"ron,MA 0270or�i o °gG POTENTIAL STRUCTURAL ISSUES OBSERVED PHONE F VINCENT m PRIOR TO PROCEEDING W/INSTALLATION. FAX 0 0 MWUMVANEZA ,, CIVIL •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" CUSTOMER RESIDENCE: N.. 2 BOUNDARY REGION OF ANY ROOF PLANE ALTA HIGH 10,4 E• ,,tee EDGES(EXCEPT VALLEYS),THEN 16 BENJAMIN WAY,YARMOUTH, `/•'ONALO Signed:1123/2022 ATTACHMENTS NEED TO BE ADDED AND MA,02673 - OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: TEL.(508)862-6377 **ALLOWABLE ATTACHMENT SPACING APN:YARM-000064-000053 INDICATED ON PLANS TO BE REDUCED BY 50%. PROJECT NUMBER: ••ALLOWABLE OVERHANG INDICATED ON 223R-018HIGH PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. DESIGNER: 015)580-6920 ex3 AMY CYZMAN SHEET LAYOUT REV:A 11/23/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 • rempare_v n_a 0 07 7 1 120240 VAC SINGLE PHASE SERVICE O METER St. < EVERSOURCE 2797045 UTILITY Li GRID C:mn !LYUu 14! vv-4'_,c .—SUPPLY SIDE TAP fr I , y EXISTING i -- 1 — GEN —— ''----'(-1) -'(4� (N)100A PV LOAD TRANSFER �- CENTER 7 to SWITCH a i w (N)LOCKABLE L, 20';_<OVA:: (I EXISTING 200A BLADE TYPE (N)MA SMART F MAIN BREAKER FUSED AC UTILITY _ .. {I-__--.. SOLAREDGE TECHNOLOGIES. DISCONNECT REVENUE SE6000H-USSN METER 6000 WATT INVERTER JUNCTION BOX PV MODULES �\ (,,) j4� \3) `2�, OR EQUIVALENT (�,, LONGI GREEN ENERGY TECHNOLOGY EXISTING ti(1 \ _ 200A / CO LTD:LR4-60HPH-360M �� MAIN `� �' O IJ • 1) ../` — �'� '(1)/ (24)MODULES FACILITY PANEL T OPTIMIZERS WIRED IN: LOADS WA FUSES I I (1)SERIES OF(12)OPTIMIZERS ..1."w o SQUARED 240V METER SOCKET 60A BREAKER(E) LOAD RATED DC DISCONNECT L (1)SERIES OF(12)OPTIMIZERS D223NR8 100A CONTINUOUS 35A BREAKER(N) WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,100A UTILITY SIDE OF CIRCUIT COMPLIANT P401 I 120240VAC CONNECTS TO TOP LUGS- (UNE AT TOP LOAD AT BOTTOM) 1 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 sun ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 1"EMT OR EQUIV. (2)3 AWG THHWTHWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 • #180120 E EXISTING SYSTEM 695 MILES STANDISH BLVD,TAUNTON,NA,027867331 R1ONE 0 FAA 0 CUSTOMER RESIDENCE: ALTA HIGH MODULE CHARACTERISTICS 16 BENJAMIN WAY,YARMOUTH, LONGI GREEN ENERGY MA,02673 TECHNOLOGY CO LTD: LR4-60HPH-360M: 360 W P401 OPTIMIZER CHARACTERISTICS: TEL.(508)862-6377 OPEN CIRCUIT VOLTAGE: 40.5 V MIN INPUT VOLTAGE: 8 VDC APN:YARM-000064-000053 MAX POWER VOLTAGE: 34 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: SHORT CIRCUIT CURRENT: 11.35 A MAX INPUT ISC: 11.75 ADC 223R-016HIGH MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 Bx3 SYSTEM CHARACTERISTICS-INVERTER 1 AMY CYZMAN SYSTEM SIZE 8640 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 22.74 A REV:A 11/23/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 Templefs_vers,00_4.0.87 I 1 -.A �,A RN I NG INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE .. "` PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INSIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANELAC/DC (IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER (IF APPLICABLE). PER CODE(S):NEC 2020:690.13(B) NOTICE WARNING: PHOTOVOLTAIC PV SYSTEM COMBINER PANEL nirIi/� NINNN POWER SOURCE DO N_O_T ADD LOADS TO THIS PANEL LABEL LOCATION. LABEL LOCATION: LOAD CENTER DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY IO FT, (Only use when applicable for PV load center) SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 805.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN CAUTION : SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH AWARNING MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS IV OVERCURRENT DEVICE LABEL LOCATION: INSTALLEDWTHINNECO20:H 90 DOWN (E) SOLAR PANELS sun run LABEL LOCATION: SWITCH PER CODE(S):NC 2020:690.58(C)(2),IFC ON ROOF ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). 1111 PER CODE(S):NEC 2020: 4„ 705.12(B)(3)(2) SOLAR PANELS llll /\WARNI . SOLAR PV SYSTEM EQUIPPED ON ROOF MMII #180120 PHOTOVOLTAIC SYSTEM MI 6.MYLES STANDISH BIvo.TAUNTON.MA Oneo-73J+ COMBINER PANEL WITH RAPID SHUTDOWN PHONE0 ` DO NOT ADD LOADS III. USTALTA MHIEH Mill CUSTOMER RESIDENCE: LABEL LOCATION: MAIN PANEL (INT) - _ 16 BENJAMIN WAY,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF -�jIINVERTER (EXT) MA,02673 APPLICABLE). 3' TURN RAPID SHUTDOWN PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) TEL.(508)862-6377 SWITCH TO THE"OFF" POSITION TO SHUT DOWN SERVICE ENTRANCE PV LOAD CENTER APN:YARM-000064-000053 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:25.00 SHOCK HAZARDINTHE (E) PV EQUIPMENT -PV PRODUCTION 223R-016HIGH NOMINAL OPERATING AC VOLTAGE: 240 VAC'.. ARRAY. 11,1 FUSED AC DISCONNECT- METER DESIGNER: (415)580-6920 ex3 LABEL LOCATION: 16 BENJAMIN WAY, YARMOUTH, MA, 02673 AMY CYZMAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. _ —. -- SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: S I G N AG E ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 11/23/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0 t rampar•_wrloon_e.D 87 I,