HomeMy WebLinkAboutBLDE-23-002129 - Commonwealth of Official Use Only fE Massachusetts Permit No. BLDE-23-002129 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/20/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 229 GREAT WESTERN RD Owner or Tenant JUSTIN EMERALD Telephone No. Owner's Address 229 GREAT WESTERN ROAD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (33 Panels 13.2 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Ton l No.of Alerting Devices No.of Waste Disposers Heat Pump Number _ Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) '73Z- 714- - l 2-ta Y I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: BRIAN K MACPHERSON Licensee: Brian K Macpherson Signature LIC.NO.: 21233 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:32 GROVE ST,DBA TRINITY SOLAR,PLYMPTON MA 023671306 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 c7. J lli\t0i,IVl`G. OF i nn t (..—S 6 4C-0 12'(- \ s I 19 202 /� / �j permits.wareamttit* lyysolar.com ( ommonwea�h o�///aaaac�eu�e�fa Permit No3 I�� t' e, y UE.t'ART?v1ENT aL.Je artment o 3ire Servicee P I l d_ - Occupancy and Fee Checked :OARD OF FIRE PREVENTION REGULATIONS [Rev. I/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK (PLEASE PRIM tP'9r pAb rfoprp�lyfLa emillpost? jt l ph psachusetts Electrical Code�MEC2 527 022 MR 12.00 Yarmouth Date: City or Town of: To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 229 Great Western Rd S. armouth, MA 02664 Owner or Tenant 1 Justin Emerald Telephone No.774-368-0447 Owner's Address 229 Great Western Rd S.Yarmouth, MA 02664 Is this permit in conjunction with a building permit? Yes x No (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service Amps 120 / 240 Volts Overhead y Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Install 13.2Kw panels will not exceed roof panels but will add 6" to roof height. 33panels tota6le be waived the Completion of the following_ may by Inspector of Wires. of- tal No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Detection and No.of Switches No.of Gas Burners Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other C ion No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KWNo.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: 33 total panels A detail if desired,or as required by the Inspector of Wires. 64170.00 Hach additional Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start: TBD Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND ® OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this app 6'Lion is true and complete. FIRM NAME: Trinity Solar Inc LIC.NO.: 4434A1 filMieetb/eBeIgarrAimpliellienithe license number line.) Signature 04: LIC.NO.: 21233A Bus.Tel.No.:508-291-0007 Address: 32 Grove St.Plympton,MA 02367 Alt.Tel.No.: 774 271 1858 *Per M.G.L.c. 147,s.57-61,security work requires Department of Publ • afety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent PERMIT FEE:$ Signature Telephone No. INSTALLATION OF NEW GREAT WESTERN ROAD. ROOF MOUNTED PV SOLAR SYSTEM - 229 GREAT WESTERN ROAD SOUTH YARMOUTH, MA 02664o _ j Issued/Revisions • II *M 'MIT 11.1•12 ID VICINITY MAP SITE NO. DESCRIPTION DATE SCALE:NTS Project Title: EMERALD,JUSTIN- TRINITYACCT le:2022-03-755521 Project Address: 229 GREAT WESTERN ROAD SOUTH YARMOUTH,MA 02664 41.685149,-70.165876 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX PV-1 COVER SHEET W/SITE INFO&NOTES Drawing Title: 1.THE INSTALLATION CONTRACTOR IS 8. THE CC VOLTAGE FROM THE PANELS IS 14. 8)CURRENT PREVAILING UTILITY 18 (UNCTION BO% RESPONSIBLE FOR INSTALLING ALL EQUIPMENT ALWAYS PRESENT AT THE DC DISCONNECT COMPANY SPECIFICATIONS,STANDARDS, kCMll THOUSAND CIRCULAR MILS AND FOLLOWING ALL DIRECTIONS AND ENCLOSURE AND THE DC TERMINALS OF THE AND REQUIREMENTS WA KILO-VOLT AMPERE PL/ -1 L (/. INSTRUCTIONS CONTAINED IN THE DRAWING INVERTER DURING DAYLIGHT HOURS.ALL 15 THIS SET OF PLANS HAVE BEEN PREPARED kW KILO VWATT ROOF PLAN W/MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM PACKAGE AND INFORMATION RECEIVED FROM PERSONS WORKING ON OR INVOLVED WITH FOR THE PURPOSE OF MUNICIPAL AND DWN KILOWATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM TRINITY. THE PHOTOVOLTAIC SYSTEM ARE WARNED AGENCY REVIEW AND APPROVAL.ONCE LINE 3.THE INSTALLATION CONTRACTOR IS THAT THE SOLAR MODULES ARE ENERGIZED APPROVED,THE INSTALLATION MCB MAIN CIRCUIT BREAKER RESPONSIBLE FOR INSTALLING All EQUIPMENT WHENEVER THEY ARE EXPOSED TO LIGHT. CONTRACTOR IS RESPONSIBLE FOR MOP MAIN DISTRIBUTION PANEL AP APPENDIX Drawing Information AND FOLLOWING ALL DIRECTIONS AND 9. ALL PORTIONS OF THIS SOLAR INSTALLING ALL SYSTEM COMPONENTS AS MLO MAIN LUG ONLY DRAWING DATE: 9/ISMO, INSTRUCTION CONTAINED IN THE COMPLETE PHOTOVOLTAIC SYSTEM SHALL BE MARKED DESCRIBED IN THE DRAWING PACKAGE. MTD MOUNTED DRAWN BY: it MANUAL. CLEARLY IN ACCORDANCE WITH THE 16 ALL INFORMATION SHOWN MUST BE AUG MOUNTING REVISED BY: 3.THE INSTALLATION CONTRACTOR IS NATIONAL ELECTRICAL CODE ARTICLE 690 a CERTIFIED PRIOR TO USE FOR N NEUTRAL RESPONSIBLE FOR READING AND JOS. CONSTRUCTION ACTIVITIES. NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS.COMPONENT 10. PRIOR TO THE INSTALLATION OF THIS MC NOT IN CONTRACT AND INVERTER MANUALS PRIOR TO PHOTOVOLTAIC SYSTEM,THE INSTALLATION NOR NUMBER System Information: INSTALLATION.THE INSTALLATION CONTRACTOR SHALL ATTEND A NTS NOT TO SCALE DC SYSTEM SIZE: 13.2%W CONTRACTOR IS ALSO REQUIRED TO HAVE ALL PRE-INSTALLTION MEETING FOR THE REVIEW ABBREVIATIONSOCP OVER CURRENT PROTECTION AC SYSTEM SUE: IOYW COMPONENT SWITCHES IN THE OFF POSITION OF THE INSTALLATION PROCEDURES, P POLE AND FUSES REMOVED PRIOR TO THE SCHEDULES,SAFETY AND COORDINATION. AMP AMPERE pp PULL BOX MODULE COUNT: 33 INSTALLATION OF ALL FUSE BEARING SYSTEM 11. PRIOR TO DIE SYSTEM START UP THE AC ALTERNATING CURRENT PH0 PHASE MODULES USED: HANWHA ROB COMPONENTS. INSTALLATION CONTRACTOR SHALL ASSIST IN Al ALUMINUM PVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC N: QPLAK DUO BIB MI-OLD.a.40o 4.ONCE THE PHOTOVOLTAIC MODULES ARE PERFORMING ALL INITIAL HARDWARE AF AMP.FRAME PWR POWER MOUNTED,THE INSTALLATION CONTRACTOR CHECKS AND DC WIRING CONDUCTVIIY AFF ABOVE FINISHED FLOOR STY QUANTITY UTILITY ACCTOCOMPANY IETEAEVERSOUR[F SHOULD HAVE AD HAS OF ONE CHECKS. AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITY KCTR 14360030040 ELECTRICIAN WHO HAS ATTENDED A SOAR 13. FOR THE PROPER MAINTENANCE AND AWG AMERICAN WIRE GAUGE pry SOLD NEUTRAL UTILITY METER N: 2335349 PHOTOVOLTAIC INSTALLATION COURSE ON SITE. ISOLATION OF THE INVERTERS REFER TO THE C CONDUIT(GENERIC TERM OF FSWBD SWITCHBOARD DEAL TYPE. SUNHOVA RACEWAY, 5.FOR SAFETY,IT IS RECOMMENDED THAT THE ISOLATION PROCEDURES IN THE OPERATION RACEWAY,PROVIDE AS SPECIFIED) TYP TYPICAL INSTALLATION CREW ALWAYS HAVE A MANUAL. COMBINER BCD U.O.I. UNLESS OTHERWISE INDICATED MINIMUM OF TWO PERSONS WORKING 13. THE LOCATION OF PROPOSED ELECTRIC AND CB CIRCUIT WP WEATHERPROOF TOGETHER AND THAT EACH OF THE TELEPHONE°DDES ARE SUBJECT TO FINAL CT CURRENT TRANSFORMER %FMR TRANSFORMER Rev.No. Sheet INSTALLATION CREW MEMBERS BE TRAINED IN APPROVAL OF THE CT APPROPRIATE UTILITY COPPER L., MOUNT 72 INCHES TO BOTTOM OF , FIRST AID AND CPR COMPANIES AND OWNERS. CU DIRECT CURRENT ABOVE FINISHED FLOOR OR GRADE 6.THT FLlOWINGTAICOT SYSTEM IS 14. ALLONSTRURMLN FORW THE SITE AND DCIDISCONNECT �n1 �]" AE ISINSTALLEDSOUNLIOECTRIC E COEM IS TO BE MAECTIONFHOWN DISC DRAWING r1 r V �1// THE NATIONAL ELECTRICAL CODE.ANY LOCAL IMPROVEMENTS SHOWN HEREIN SHALL BE DWG ELECTRICAL SYSTEM INSTALLER CODE WHICH MAY SUPERSEDE THE NEC SHALL IN ACCORDANCE WITH: EC ELECTRICAL METALLIC TUBING GOVERN. ACURRE NT PREVAILING MUNICIPAL EMT FUSIBLE SWITCH 7.ALL SYSTEM COMPONENTS TO BE INSTALLED AND/OR COUNTY SPECIFICATIONS, FS FUSE lib WITH THIS SYSTEM ARE TO BE'UV LISTED.ALL STANDARDS AND REQUIREMENTS FU GROUND EQUIPMENT WILL BE NEMA 3R OUTDOOR GND GROUND FAULT INTERRUPTER Trinity° RATED UNLESS INDOORS. Gil FREQUENCY(CYCLES PER SECOND( HZ GENERAL NOTES SOLAR IF ISSUED DRAWING IS MARKED WITH REVISION(NARACTER OIHER THAN'A.',PLUS(BE ADVISED IHDH EINAI EQUIPMENT AND/OR SYSILMCHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLIIY Dl EQUIPMENT. 2211 Allenwood Road B77-736-72B3 Wall,New Jersey 07719 www,1DYAT'SDLBr.fvn NOTES:MUER TO MODULE SPECS FOR MODULE DIMENSIONS •DEPICTEDMODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP bril I NEW N SOLAR MODULE.TYPICAL IMNR TO SPEcnaT rworrnGI IPEFER TO EDUPMENT XHEDDIE FOR MI sPF(S ANDOWNTmFsI SOLAR MODULE SOLAR MODULE NEW MOUNTING FOOT/ATTACNMFM Y \II I/ • IECOFASTEN"L"FOOT ECOFMTENMIL BEMTOBEMDUxifOPEwlxgculMiO EXISTING ASPHALiSNINGlES iiiH STRUCfUREIREfFR TO FCOFMTFXSPEC IMRRTOEMBIx[MS«rteRFa ROI L_ IureR TosrECSrn rwoONUI ,N 6 NEW END CLIP,/DATA SHEET FOR DETAILS l NEW END CLIP,TYPICAL S.S.LAG BOLT APOC SEALANT immEN / ,S2 S �•� (RELEP TOECAfASTEN SPEnxutlON/ IREDA TO ex9aKERS LEDER sa veal • SOLAR MODULESSHALLNOT // ITV\ g •BIMEELS LIMN KA SPECS � NEW MID QaOrvVIUl15) IRIFER EXISTING RAFTER EXCEED PENT HEIGHT. MUER TO ECOFASTEN SPECIFICATION/ • ATTACHMENT&CLIP DETAIL DATA SHEET FOR DETAILS PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF L.ISCALE NOT TO SCALE ©SCALE:NOT TO SCALE SGIE:NOi i0 XAIf ARRAY SCHEDULE Issued/Revisions NO. DESCRIPTION DATE Project Title: J EMERALD,JUSTIN- -- IEEOETLH uNE l --- ---I TRINITY ACCT R:2022-08-755521 w H Project Address: // I 229 GREAT WESTERN ROAD ® ® i SOUTH 41.68 149,70.165876,MA 664 MI I I Drawing Title: I I. MODULES:19 PITCH:R I ®®III II PROPOSED PV SOLAR SYSTEM ORIENTATION:I9B ® — OM ,,,111,,, , ROOF) MTCH:34 0 U I ortcH:3.• Tu��� - Drawing Information RIENiATIOR:1s• I ,,,,,,, DRAWING DATE: 9/13/101l RTOI:lEf:IA - ■ B • B `L I DRAWN BY'. Fl ORIEN BA REVISED BY: ORIENTATION:IRA --- -- - ROOF4 MODULES.:O Sy Stem Information: SiiTar ilON:ID' J ROOF 5 DC SYSTEM SOE: 13.23W MODULE;:° PITCH:3A ——————————— —— ——�— AC SYSTEM SQL W ORIENTATION:TB' - - _ MODULE COUNT: 33 ROOF MODULES USED: HANWNA 400 MOW LE1:0 MODULE SPEC B: OPEAR DUO BLit ML.G10.a..40G CH:3R ORIENTATION:IB' UTILITY COMPANY(EVEPSWRCF ROOF) UTILITY ACCI X. 1A700030040 MTCH:1OW 1E5:3'0 NOTES: UTILITY METER R. 1375349 PI ORIENTATION:M)' 1.)ALL EQUIPMENTFACT BE S INSTALLATION AN INSTRUCTIONS. DEAL TYPE: SUNK A ROOF El WITH THEAMNG TO CO PEWS(WITH MANUFACTURER CTURUCTONS. MODULES:0 1.)ARMY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITCH' 3.)ALL LOCATIONS ME APPROXIMATE AND REQUIRE FIELD VERIFICATION. ORIENTATION:SOT Rev.NO. Sheet R)AN AC DISCONNECT SL BE GROUPED WITH INVERTEMS INf C 690.13D). ML R MOpULE%:O S.NLL OUTDOORM EQUIPMENT SHALL BE IN TIGHT WITH MINIMUM NEW.3R RATING. PITCH:IB 6.IRDOFTOP SOUR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYONDTNE EXISTING ROOF EDGE. PP' PV B] /, ORIENTATION(loIOWSYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE r1 r V /_/ ROOF10 MOWlE5:0 WV SPECK PITCH:IB' INDICATESROOF DESIGNATION.REFERTO INDICATES NEW UNF USED PV DISCONNECT TO BE TO SEIESNEWPV ONLY SUBPANEI ORIENTATION:286' ® MOST SCHEDULE FOR MORE INFORMATION UD INSTALLED OUTSIDE IUTIUTV ACCESSIBLE) SP TO Bf INSTALLED 33 HANWHA 400(WEAK DUO But ML-G10.Bx ADDI ROOF MODULF5:0 INDICATES NEW PIT SOLAR MODULE.RED MODIIU:s 1 SEIWDOH-USOSHBNCA • P TC 13' I'//-••-��'I ORIENTAOIXI:IBT I M I INDICATES EXISTING METER LOCATION INDICATE P/JIELS THAT USE MICRO INVERTERS.REFER © INDICATES NEW DC DISCONNECT ��' xAr� i�� ROOF 12 LLJJJ TO EQVIPMEM SCHEDULE FOR SPECS. � 1 MODULES:o OTHER OBSTRUCTIONS _ LATCH:11' EP INDICATES EXISTING ELECTRIQLL PANEL LOCATION: I_—I INDICATES NEW PRODUCTION METER TO BE INSTALLED Sp SOLAR ORIENTAOIXI:I9T I ILYJI INDICATES EXISTING SERVICE DISCONNECT ROOF 13 ( MOD13" INDICATES INDICATES NEW INVERTER TO BE M PITCIE:13' INgCAIESNEW FUSEDP/gSCONNER TO BE 2111NIenwoOE Road a/]-)Bb-)1B1 ORIENTATION:IT Q INSTALLED OUTSIDEIUTILITYACcfSMBIE) ® INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH Wall,New lnsey0P19 www.TrinM1y-Solar.Com REFER TO EQUIPMENT SCHEDULE FOR SPECS • • / Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES 1.)UCENSED ELECTRICIAN ASSUMES AU RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND SOLAR MODULES MOUNTS O TO ROOF ON 2 ARRAYS EXECUTING INSTALLATION IN ACCORDANCE WITH 33-400W MODULES W/1 SOLAR EDGE S440 PER MODULE NEC 2020 15 ADC MAX PER STRING 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 3 STRINGS OF 11 MODULES IN SERIES-4U0 Veal - B"i8" ----- , _-- ASHRAE MINIMUM MEAN EXTREME DRY BULB JUNCTION TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO BOO INSTALLATION LOCATION.LOWEST EXPECTED AMBIENT •3 STRINGS TO RE TERMINATED IN PARALLEL INSIDE INVERTER I TEMP=-lit 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASES ON ASHRAE HIGHEST MONTH 2%DRY BULB - TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION.HIGHEST CONTINUOUS TEMP= 33T 4.)ZOOS ASHRAE FUNDAMENTALS 2%DESIGN TEMPERATURES DO NOT EXCEED 4TC IN THE UNITED STATES(PALM SPRINGS,CA IS M.1T).FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED Issued/Revisions SUNLIT CONDUIT AT LEAST 0.S"ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS (ALL OF UNITED STATES) S.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT E] wow a Tarnow Rows. NunnCONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A)THROUGH(DI NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title: SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) EXISTING2 2aa/ Ifb NOTE: EMERALD,lU6TIN- ID UNGROUNDEDIEDWITH DC CFOLLOWING INGCONDUCTORSSSH: 10 100A MAIN RUSOARBREAKER CONTAINED REVENUE GRADE MONEDGE INVERTER VIENDU CONDUCTORS FOLLOWING OUTER FINISH: UTILITY METER 100A BUSMR SOLAR ED EWITHWNOLAREDGMNVERTE0. TRINITY ACR M:202Z-08-755521 POSITIVEEG OONCTO =RED SOLAR EDGE PN.RW ND-3D-24OMB NEGATIVE CONDUCTORS=BLACK NEC 210.5(C)(3) I f Project Address: B.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE N10 PV IA, , 229 GREAT WESTERN ROAD WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRER SOUTH YARMOUTH,MA 02664 SUNUGHT.SUB ARRAY CONDUIT LONGER THAN 24'SHALL lI' 41.685149,-70.165876 CONTAIN 5 20 CURRENT CARTING CONDUCTORS AND LOCKABLE 60A DISCONNECT 60A UNFUSED INVERTER ES WHERE EXPOSED TO DIRECT SUNLIGHT SHALL FUSED W/BOA FUSES DISCONNECT _ CONTAIN 59 CURRENT CARRYING CONDUCTORS. •` 2dW ld 240V 10 0� a.0 lY Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN TOO'UNLESS leeanael L• J OTHERWISE NOTED ....�.. --- 0 l`\ I 10.)FLEXIBLE CONDUIT SHALL NOT RE INSTALLED ON ✓� 0' 1 PROPOSED PV SOLAR SYSTEM ROOFTOP AND SHALL BE LIMITED TO 1T IF USED f J OUTDOORS -",[(�G L LI N 0-' f -J 11.)OVERCURRENT PROTECTION FOR CONDUCTORS r---- C--- f"V - t B _r 1L E 0 a0 Drawing Information CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE 1 I DRAWING DATE'. 9/13/1022 LOCATED WITHIN ID'OF THE POINT OF CONNECTION NEC EXISTING MAIN BREAKER LOAD CENTER SQUARED SQUARED t J DRAWN BY: FI 690.9(A)(3)(2) INSULATED LINE TAPS INSTALLED ON PN:0222NRB DU222R13 L REVISED BY: 12.)WHERE TWO SOURCES FEED A BUSSR.ONE A - ECI7f5.12(S BA UTILITY ANO THE OTHER AN INVERTER,PV BACKFEED NEC 700. (A) BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY SYitem Information: NEC 705.12(B)(3)(2( DC SYSTEM S. 13.2kW AC SYSTEM SOS: IOMLI 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MODULE COUNT: 33 LOADS MODULES USED: IMNWIM400 MODULE SPEC IP AROSE OLIO BM MI G10.a.4D0 IA.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY:EWIISOUME A NEMA OR RATING UTILITY A[R N: 14760030010 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER R. 2375349 REQUIRED CONDUCTOR AMPACITY PER STRING DEAL TYPE: SUNNOVA [NEC G30.B(B)(1)I:(15.0081.25)1=18.75A PV MODULE SPECIFICATIONS AWG RIO,DENTED AMPACITY HAN W NA 400(Q.PLAK DUO B.ML-G104•400) AMBIENT TEMP:33'C,TEMP DE RATING FACTOR:.96 Rev.No. Sheet RACEWAY DE RATING=6 CCC:0.110 Imp 10.77 NOTE:CONDUT TYPE SNAIL BE CHOSEN BY THE INSTALLATION CONTRACTOR (40•.96)080a 30.72A VmP 37.13 TO MEET OREMCF ED NEC AND LOCAL AVID REQUIREMENTS 30.72A'18.75A,THEREFORE WIRE SIZE IS VAUD vac 45.3 A 06 THWN-2 GEC TO EXISTING GROUND ROD P1 PV He ILIATOTAL AC REQUIRED CONDUCTOR AMPACTY B 3/4"CONWR VS/2KTHWN-3.1#ICI IHWN2,1-AlOiNWX-2 GROUND 42 OOA•1.25=52.50A C 3/4"CONDUIT W/4010 THWN-2,14/10 THWN-2 GROUND AWG N6,DERATEDAMPACITY INVERTER NI•SE10000H•USDSHBNCI _ AMBIENT TEMP:30T,TEMP DERATING:ID DC AC 0 3/4'CONWO W/6#1DTIRWN-2,1#1OTHWN-2GROUND RACEWAY DERATING`_3 CCC:N/A 75A•1.047SA Imp 27 Pout 10000 E 3/4"CONDUIT W/2•A6 THWN-2.I-1I0 THWN-2,14110 THWN-2 GROUND 75A'_52.50A,THEREFORE AC WIRE SIZE IS VALID Vmp 400 Anal 42 F 1110 N WARE(FREE AIR)W/R6 MN COPPER BOND TO ARMY SOLAR CALCULATION FOR PVOVERCURRENT PROTECTION VPc 4B0 OCPOmIn 53.5 IRA INVERIERCURRLNI:42.00A I54 45 VnAm MOG 3/4"CONDUIT W/2#6 THWN-2,1#6 THWN.2,1#BTHWN2GROUND f 42.ODA•I SS=52.60A 2211 Allenwood Raab 627a6-72B3 -a 60A OVERCURRENT PROTECTION IS VALID Wall,New lerary 07719 Nana.T,nOV3ula,.4an • 1,