HomeMy WebLinkAbout19 Pine Grove solarSCOPE OF WORK GENERAL NOTES
LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE # DESCRIPTION
• • ALL WORK SHALL COMPLY WITH MA 9TH ED. CMR 780 (2015 IRC/IBC/IEBC), SOLAR MODULES PV-1.0 COVER SHEET
SYSTEM SIZE: 6935W DC, 5760W AC
• NICIPAODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION S
MODULES: (19) LONGI GREEN ENERGY TECHNOLOGY CO INSTRUCTIONS. E SERVICE ENTRANCE PV-2.0 SITE PLAN
LTD: LR4-60HPH-365M • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
• INVERTERS: (1) DELTA ELECTRONICS: E6-TL-US F8-1
MAIN PANEL PV-3.0 LAYOUT
• RACKING: RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, PV-4.0 ELECTRICAL
SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
• MAIN PANEL REPLACEMENT: EXISTING 125 AMP MAIN SNR MOUNT PV-5.0 SIGNAGE
PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY SP SUB -PANEL SNR MOUNT & SKIRT
WITH NEW 125 AMP MAIN PANEL WITH 100 AMP MAIN GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
BREAKER. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
• RAPID SHUTDOWN: (19) APSMART RSD-S-PLC ROOFTOP CHIMNEY
MODULE LEVEL RAPID SHUTDOWN DEVICE • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• NEW 100A MAIN BREAKER DISCONNECT WITH 100A MAIN SM SUNRUN METER
ENCLOSURE • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT
FLUSH ATTIC VENT
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II PM DEDICATED PV METER PVC PIPE VENT
vi MODULES, ARE CLASS A FIRE RATED.
l� METAL PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL [INV INVERTER(S)
�f (/ CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT
AC
J •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). IlEill AC DISCONNECT(S) SATELLITE DISH
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
• 11.43 AMPS MODULE SHORT CIRCUIT CURRENT.
0 DC DISCONNECT(S) F7A
FIRE SETBACKS
• 17.85 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)]. CB IQ COMBINER BOX HARDSCAPE
• PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE F_ —1 INTERIOR EQUIPMENT — PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L_ J SHOWN AS DASHED SCALE: NTS
A AMPERE sunrun
AC ALTERNATING CURRENT
AFCI ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION #180120
DC DIRECT CURRENT
(E) EXISTING 734 FOREST STREET #400, MARLBOROUGH, MA 01752
PHONE 888.657.6527
ESS ENERGY STORAGE SYSTEM FAX805.528.9701
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
MAG MAGNETIC CLIVE MOORE
MSP MAIN SERVICE PANEL 19 PINE GROVE RD,
(N) NEW YARMOUTH, MA, 02664
NTS NOT TO SCALE
OC ON CENTER TEL. (929) 282-8248
PRE-FAB PRE -FABRICATED APN: YARM-000041-000043
PSF POUNDS PER SQUARE FOOT PROJECT NUMBER:
PV PHOTOVOLTAIC 221 R-019MOOR
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS DESIGNER: (415) 580-6920 ex3
TYP TYPICAL PRIYANKA KUMARI
V VOLTS
W WATTS SHEET
REV NAME DATE COMMENTS OVER SHEET
REV: Al 11/5/2022
PAGE PV-1.0