HomeMy WebLinkAbout12 Denise Ln solarPHOTOVOLTAIC SYSTEM PV SYSTEM SUMMARY: 7.000 KW RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE (DC) STC: 20 X 350 = 7000W DC PTC: 20 X 326.8 = 6536W DC SYSTEM SIZE (AC) 5000W AC @ 240V MODULES 20 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS 20 X SOLAR EDGE: S440 INVERTER : SOLAR EDGE: SE5000H-USRGM [S11] TILT 38°, 11 ° AZIMUTH 143°, 323' ROOF COMPOSITION SHINGLE RAFTER/TRUSS SIZE 2X8 RAFTER @ 24" O.C. ECOFASTEN: ROCKIT MICRORAIL WITH SLIDERS ATTACHMENT TYPE RAIL -LESS EXISTING 100 AMPS MSP WITH (E) 100 AMPS MAIN MAIN SERVICE PANEL BREAKER ON END FED INTERCONNECTION LINE SIDE TAP OCPD RATING 30 AMPS UTILITY EVERSOURCE ENERGY TABLE OF CONTENTS PV-1 SITE LOCATION AND HOUSE AERIAL VIEW PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 EXISTING SERVICE PANEL PV-6 NOTES AND EQUIPMENT LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 & 10 SAFETY PLAN ,.e do, T rfl FREEDOM FOREVER MASSACHUSETTS LLC 135 ROBERT TREAT PAINE DR., TALTON, MA 02780 Tel: (800) 385-1075 ELECTRICAL CONTRACTOR NO: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-Al; CONSTRUCTION SUPERVISOR LICENSE CS-111662; MASTER ELECTRICIAN 1136 MR MATTHEW MARKHAM CLIENT: CITY NOTES_ THIS PROJECT COMPLIES WITH THE FOLLOWING: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE 2020 NATIONAL ELECTRICAL CODE AS ADOPTED BY TOWN OF YARMOUTH CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. INSTALLATION NOTES: DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. Ll e -i eZ3 - C 10z�5q PIERRE MERHI 12 DENISE LANE, SOUTH YARMOUTH, MA 02664 REVISIONS: DESCRIPTION DATE I REVISION nil �. �- uuA (_ 38515 b"IS ik sealed 15nov2022 mike@h2dc.com H2DC PLLC MA CoA#: 001239603 ELECTRICAL ONLY NOT AN AS -BUILT DRAWING SET Digitally signed by Michael McGuire PE D Michael N: CHUS, SH D Hhire, L=Mason can , NHurrie Hit Devamps ill elopment Company PLLC, OU=Electrical PE, CN=Michael McGuire PE, E=mike@h2dd— M C G U i re P E Reason agree to specified pads of this tlocumen Location' your signing location here )ate'. 2g22.1 it., 12:2]:2] 1.2,3 Fozit PDF Editor Version. 11.2 3 SITE LOCATION: HOUSE AERIAL VIEW: MODULE LOCATION TITLE: SHEET: DATE: 14/ 11 /2022 DESIGN AP SITE LOCATION AND BY. HOUSE AERIAL VIEW PV-1 JOB NO.: 279977