HomeMy WebLinkAbout12 Denise Ln solar007GENERAL NOTES: 20 LONGI SOLAR WIRED AND LISTED TO UL1703 STANDARDS THE SOLAREDGE INVERTER IS INTEGRATED WITH DC DISCONNECTION AND ARC FAULT PROECTION. IT IS ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS W/ GROUND FAULT PROTECTION & LISTED TO UL 1741 STANDARDS. PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1 INCH FROM TOP OF THE ROOF TO BOTTOM OF RACEWAY. TABLE NEC 310.15(B)(3)(C) PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET -- AhD WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES WALLS OR BARRIERS -- WITH MINIMUM 3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUND READING: WARNING: PHOTOVOLTAIC POWER SOURCE. SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THE REQUIREMENTS OF 2020 NEC THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVIATION OF THE SOLAR PV SYSTEM TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS MATERIAL LIST: 11 A � u ;'b 0 s �X sealed 15nov2022 mike@h2dc.com H2DC PLLC MA CoA#: 001239603 ELECTRICAL ONLY NOT AN AS -BUILT DRAWING SET QTY. PART PART # DESCRIPTION L 20 MODULES 114-350 LONGI SOLAR: LR4-60HPB-350M 20 OPTIMIZERS 130-401 P401 SOLAREDGE POWER OPTIMIZER - FRAME MOUNTED MODULE ADD -ON 1 JUNCTION BOX 480-276 60OVDC NEMA 3R UL LISTED JUNCTION BOX / MULTI MC4 CONNECTORS (FEMALE) BREAKER SIZES: 2 2 CONNECTORS CONNECTORS 240-300 240-301 STAUBLI -CONTACT STAUBLI / MULTI —CONTACT MC4 CONNECTORS (MALE) 1 INVERTER 120-503 SE5000H—USRGM [Sill 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 323-065 60A RATED 240VAC NEMA 3R UL LISTED 2 FUSES 330-030 30A FUSE 1 PH 240VAC 1 FUSE REDUCER 330-530 60A-30A FUSE REDUCER 1 PRODUCTION METER 322-100 MILBANK U5929—XL—INS SINGLE PHASE NEMA 3R 600V/100A FORM 2S 1 CLOSING PLATE 322-302 MILBANK METER CLOSING PLATE (USED WITH U5929—XI) 1 TAP KIT 350-111 #6 — 3/0 AWG INSULATED TAP 2 PORT 36 ROOF ATTACHMENT 1 261-602 ECOFASTEN: ROCKIT RAIL —LESS 35 MICRORAIL 1 261-602 SFM MICRORAIL 2 INCH 15 SFM TRIM 1 241-253 FLASHKIT SFM TRIM COMP DARK 38 SFM SLIDER 1 261-603 FLASHKIT SFM SLIDER COMP DARK 11 BONDING CLAMP 1 221-100 SFM N/S BONDING CLAMP 5 BONDING CLAMP 1 241-404 SFM TRIM BONDING CLAMP 21 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY 12 SFM SPLICE 1 261-604 SFM SPLICE 3 SFM ATTACHED SPLICE 1 211-101 SFM ATTACHED SPLICE 8 INCH 17 TRIMRAIL 1 261-606 SFM TRIMRAIL UNIV CLIP W/ HDW 5 TRIM SPLICE 1 261-605 SFM TRIM SPLICE DIRK 9 TRIMRAIL 1 SFM TRIMRAIL UNIV DRK 20 GROUND LUG 1 260-585 ILSCO GROUND LUG 20 TRIM END CAPS 1 221-200 UNIRAC SFM TRIM END CAPS SERVICE: FREEDOM FOREVER MASSACHUSETTS LLC 135 ROBERT TREAT PAINE DR., TAUTON, MA 02780 Tel: (800) 385-1075 ELECTRICAL CONTRACTOR NO: HOME IMPROVEMENT CONTRACTOR 198080; BUSINESS ELECTRICAL CONTRACTOR LICENSE 902-EL-At; CONSTRUCTION SUPERVISOR LICENSE CS-111662; MASTER ELECTRICIAN 1136 MR MATTHEW MARKHAM CLIENT: PIERRE MERHI 12 DENISE LANE, SOUTH YARMOUTH, MA 02664 REVISIONS: DESCRIPTION I DATE REVISION DATE: 1 14/ 11 /2022 DESIGN AP BY: JOB NO.: 279977 TITLE: NOTES AND EQUIPMENT LIST SHEET: PV-6