NEC 690.15 (B) & NEC 690
SINGLE 120-VOLT SUPPLY
DO NOT CONNECT
MULTIWIRE BRANCH CIRCUITS
NEC 710.15(C) & 692.9 (C)
AWARNING DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
NEC 705.12(D) & NEC 690.59
A WARNING
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
NEC 110.27(C) & OSHA 1910.145(F)(7)
'A..,WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
706.15(C)(4) & 690.13(B)
A WARNING
THIS EQUIPMENT FED BY
MULTIPLE SOURCES:
TOTAL RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN POWER
SUPPLY SHALL NOT EXCEED
AMPACITY OF BUSBAR
NFC 705.12(B)(3)(3)
A WARNING
THE DISCONNECTION OF THE
GROUNDED CONDUCTOR(S)
MAY RESULT IN OVERVOLTAGE
ON THE EQUIPMENT
FREEDOM FOREVER MASSACHUSETTS
LLC
135 ROBERT TREAT PAINE DR., TAL TON, MA 02780
Tel: (800) 385-1075
(9
U
Q
2
a
►I INVERTER
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID
SHUTDOWN SWITCH TO
THE "OFF" POSITION TO
PV PANELSIC
SHUT DOWN PV SYSTEM
AND REDUCE SHOCK
HAZARD IN THE ARRAY
NEC 705.12(C) & NEC 690.59 NEC 706.15(C) AND NEC 110.16
690
RATED AC • 21.00A
NOMINALOPERATING AC VOLTAGE:240V
NEC 690.54 I
AWARNING DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
NEC 705.12(D) & NEC 690.59
I
ELECTRIC SMXK H"ARO EVERY 10' ON CONDUIT AND ENCLOSURES
NEC 690.31(0)(2)
Y� 9M{MHM PO&'raGt
hnifatb�Tkm_bYskHM N§E
1.IHGpP4➢N@AMrN!EN6i&32t9 PHOTOVOLTAIC
•••/ POWER
•. • .
wtttTUVm.Fm[ crsi£M
OC.65GONNECT
AUTHORIZED PMON14EL ONLEVERY 10' ON CONDUIT AND ENCLOSURES
Nate: WARNING labels must resemble format NEC 690.31(D)(2)
in example above with over -sized WARNING,
exclamation point in triangle, colors, etc.
ELECTRICAL CONTRACTOR NO. CLIENT:
HOME IMPROVEMENT CONTRACTOR
198080: BUSINESS ELECTRICAL
CONTRACTOR LICENSE 902-EL-Al;
CONSTRUCTION SUPERVISOR
LICENSE CS-111662; MASTER
ELECTRICIAN 1136 MR
MATTHEW MM/ARRKKHAM
i i�%�c...-,
PIERRE MERHI
12 DENISE LANE,
SOUTH YARMOUTH, MA 02664
NjnTFS-
1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS
SHOWN HEREON.
2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:
A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR
MACHINE PRINTED LETTERS OR ELECTRO-PLATING.
B. RED BACKGROUND COLOR WHITE TEXT AND LINE
WORK.
C. AERIAL FONT.
3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN
THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE
HAND-WRITTEN.
3. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH
POP -RIVETS OR SCREWS.
PHOTOVOLTAIC
DC DISCONNECT
MAXIMUM DC VOLTAGE
OF PV SYSTEM___
DC
REVISIONS:
DESCRIPTION
A WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT
WHEN SOLAR MODULES
A- FYD Qrn Tn CI IMI Ir.NT
706.15(C)(4) & 690.13(B)
DATE I REVISION
J/B
DATE: 1 14/11 /2022
DESIGN I AP
BY:
JOB NO.:1279977
H, f;()CiIP'E
sealed 15nov2022 mike@h2dc.com
H2DC PLLC MA CoA#: 001239603
ELECTRICAL ONLY
NOT AN AS -BUILT DRAWING SET
A WARNING
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
(Ub.IS(U)(4) & b9U.1S(b)
A WARNING
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
NEC 110.27(C) & OSHA 1910.145(F)(7)
ARRAY
NEC 690.31(G)(3) & (4)
TITLE: I SHEET:
LABELS I PV-7