HomeMy WebLinkAbout12 Denise Ln solar015PV power optimization at the module level
Specifically designed to work with SolarEdge
residential inverters
Superior efficiency (99.5%)
Mitigates all types of module mismatch loss,
from manufacturing tolerance to partial shading
Faster installations with simplified cable
management and easy assembly using a single bolt
Frost onality subject to inve ter model and f rm w as e vesor
sofaredge.com
Detects abnormal PV connector behavior,
preventing potential safety issues`
Module -level voltage shutdown for installer and
firefighter safety
Flexible system design for maximum space utilization
Compatible with bifacial PV modules
Power Optimizer
S440,S500
S440 S500 UNIT
L�
Rated Input DC Power"-
440 S00
W
Absolute Maximum Input Voltage (Voc)
60
Vdc
MPPT Operating Range
8 -60
Vdc
Maximum Short Circuit Current (Ise) of Connected PV Module
14.5
Adc
Maximum Efficiency
1 99,5
Weighted Efficiency
Overvoltage Category
F 98.6
OUTPUT DURING OPERATION
Maximum Output Current 15 Adc
Maximum output Voltage 60 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 Vdc
----------------------------- ----
EMC
------- ----- -----------------------------------------------
FCC Part 15 Class 3, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-550'1
----
Safety 1
IEC62109-1 (class II safety), UL1741
Material -}
UL94 V-0, UV Resistant
------------------------------
---
RoHS
Yes
Fire Safety
VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage
1000
Vdc
Dimensions (W x L x H)
129 x 153 x 30
mm
Weight (including cables)
655 /1.5
gr/ lb
Input Connector
MC4ur
Input Wire Length
0.1
m -
Output Connector
MC4
Output Wire Length
+) 2.3, (-) 0-10
m _
Operating Temperature Ranger'
40 to +85
C
Protection Rating
IP68 / NEMA6P
Relative Humidity
0 - 100
(1) Rated power of ;he module at STC will not exceed the power optimizer Rated Input DC Power. Modules with op to +5/ power tolerance area owe
(2) For ocher connector Types please contact SolarEdge
(3) For amb-ent temperature above —70'C / +158°F power de-rat.ng is applied- Refer to Power Optimizers Temperature De -Rating Technical Note for more details
Minimum String LengthI 5440, 5500 8 16 18
(Power Optimizers)
Maximum String Length (Power Optimizers) I 2S 50
-----------------
Maximum Nominal Power per String!') 5700 5250 11250ta� 12750re W
Parallel Strings of Different Lengths or Orientations Yes
(4) If the ieve,ters rates AC power < maximum nominal power per string, then the maximum trowel per string will be able to reach up .o the Inver—s maximum input DC Dower
Refer to hGpsy/www.solaredge com/sites/cefault/(iles/se-power-opt mizer-single-shr rg-des,gn-appricalion-note-pdr
(5) For the 230/400V gr d. t is allowed to install up to 13,S00W pe, sung when the maximum power difference between each strirg is 2,000W
(6) For the 277/480V grd- it Is allowed to install uo to 15,000W per string when the maximum power difrererce between each string is 2,000W
(7) It is not allowed to mix S-series and P-series power optimizers in new Installations
,53
hR ,
3a6
Sola rEdge Technolog-es, Inc All rights reserved. SOLAREDGE, the SolarEdge logo OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Tech noloq es Inc.
All other iadaarks mentioned herein are trademarks of their respective owners. Date: 06/2021 DS-000052-10-ENG-NL. Subject to change without notice.
CE ROVES