HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out_ Acreage
/„c f'11�0 A_, Commercial: Residential:
Street: (.(i !J1'
Village: Floor Plan: r �''/ # Bedrooms:
Owner: Installer: Eli C_4 'V4O7S
Address: Phone:
Phone:
Builder: Engineer: cba/S'Y.GG(, .,v
Address: Phone: ���
Phone:
N/A YES NO
1.Required# of copies received
2. Date of soils exam and percolation test not older than 2 years -
3. 4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: V
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: ✓
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓
15. System not in top or subsoil(A,B horizons) or 5' removal v
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1/4"preferred ✓�
18. System meets breakout requirements PVC liner: Wall: ✓
19. Specified tee sizes are proper, gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel
-_ 21. No garbage disposal
22. System adequately sized for its intended use V
23. Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade, pump chamber cover to grade ✓
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes ✓
27. Pump system-2" line,weep hole,check valve, tee in dbox,pump size J
28. Septic tank/pump chamber to be factory waterproofed V
29. Vent provided if leaching below 3 feet, under driveway/parking ✓
30. Buoyancy calculations for tank/pump chamber ✓
31. Engineer to inspect and certify soils: wall: commercial: ✓
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature v"
33. H-20 loading is subject to vehicular traffic, groundwater v
34. Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house 47;
36. Deed Restriction required max. #bedrooms: max. flow: gpd ✓
37. Check area lots for groundwater/Label gr u d a in essor's Map
Plan reviewed by: {I
6/03/03